Experimental study on the chemico-physical interaction between a two-component cyanoacrylate glue and the material of PICCs

Introduction: The use of cyanoacrylate glue as sealant on the exit site of peripherally inserted central catheters (PICCs) may offer some important clinical advantages. However, concerns exist about the potential interaction between cyanoacrylate and the material of the catheter itself. The aim of this study was to investigate the possibility of damage to the catheter secondary to a long-term contact with a two-component skin glue (N-butyl + octyl cyanoacrylate). Methods: Twelve PICCs of different brands and types were selected (11 made of polyurethane and one made of silicon). PICCs were glued onto artificial skin pads, slightly wetted with Earle solution. The pads were kept in an egg incubator at 34°C and 60% humidity, for up to twelve weeks. Possible signs of degradation were monitored by surface analyses and mechanical tests. Scanning electron microscopy observations, surface roughness measurements, pressure strength and uniaxial tests were performed. Results: Samples were analyzed after 4, 8 and 12 weeks of contact with the glue. No chemical reaction between the glue and the material of the catheters was evident. The mechanical strength of PICCs was consistently within the ranges of ISO standards. An expected increase in the stiffness of the samples covered with glue was observed in uniaxial tests. The silicon catheter was weaker than the polyurethane catheters and was damaged while trying to remove it from the pad for tests. Conclusions: The long-term use of N-butyl + octyl cyanoacrylate glue on polyurethane PICCs is not expected to be associated to any damage to the catheter.

[1]  G. Gallone,et al.  Experimental Investigation on the Mechanical Behavior of Polyurethane PICCs after Long-Term Conservation in in Vivo-Like Conditions , 2017, The journal of vascular access.

[2]  J. Fraser,et al.  Skin Glue Reduces the Failure Rate of Emergency Department-Inserted Peripheral Intravenous Catheters: A Randomized Controlled Trial. , 2016, Annals of emergency medicine.

[3]  G. Gallone,et al.  A Comparative Study on the Mechanical Behavior of Polyurethane PICCs , 2016, The journal of vascular access.

[4]  D. Biasucci,et al.  Further benefits of cyanoacrylate glue for central venous catheterisation , 2015, Anaesthesia.

[5]  M. Hacking,et al.  Histoacryl® for securing central venous catheters: not so sticky! , 2014, Anaesthesia.

[6]  A. Hedjazi,et al.  Cyanoacrylate Glue Dressing for Hypospadias Surgery , 2012, North American journal of medical sciences.

[7]  P. Colas,et al.  2nd World Congress on Vascular Access , 2012 .

[8]  M. Karimi,et al.  Use of Glubran 2 and Glubran tissue skin adhesive in patients with hereditary bleeding disorders undergoing circumcision and dental extraction , 2011, Annals of Hematology.

[9]  M. Chikhani,et al.  The antimicrobial effect of Histoacryl® skin adhesive , 2008, Anaesthesia.

[10]  G. Kamali,et al.  To what extent is cyanoacrylate useful to prevent early wound infections in hernia surgery? , 2008, Hernia.

[11]  N. Sheikh,et al.  Tissue adhesive as an alternative to sutures for securing central venous catheters , 2007, Anaesthesia.

[12]  F. Di Puccio,et al.  A new method for artificial chordae length "tuning" in mitral valve repair: preliminary experience. , 2007, The Journal of thoracic and cardiovascular surgery.

[13]  A. Cotroneo,et al.  Percutaneous Intravascular Retrieval of Embolised Fragments of Long-Term Central Venous Catheters , 2000, The journal of vascular access.

[14]  J. Howell,et al.  Comparison of effects of suture and cyanoacrylate tissue adhesive on bacterial counts in contaminated lacerations , 1995, Antimicrobial agents and chemotherapy.

[15]  M. Ryder Peripherally inserted central venous catheters. , 1993, The Nursing clinics of North America.