Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.

PURPOSE To evaluate continuous and simultaneous variations of thread height and width for an experimental screw-type implant. MATERIALS AND METHODS A finite element model of an implant with a V-shaped thread was created. The range of thread height was set at 0.20 to 0.60 mm, and the range of thread width was set at 0.10 to 0.40 mm. Forces of 100 N and 50 N were applied along the implant axis (AX) and an angle of 45 degrees in a buccolingual direction (45-degree BL), respectively. The maximum von Mises stresses in jawbone were evaluated, and the sensitivity of the stress in jawbone to the variables was also evaluated. RESULTS Under AX load, the maximum von Mises stresses in cortical and cancellous bones increased by 4.3% and 63.0%, respectively, as thread parameters changed. Under 45-degree BL load, maximum von Mises stresses in cortical and cancellous bones increased by 19.3% and 118.0%, respectively. When thread height was from 0.34 to 0.50 mm and thread width was 0.18 to 0.30 mm, the tangent slope of the maximum von Mises stress response curve ranged from -1 to 1. The variation of the maximum von Mises stresses in jawbone was more sensitive to thread height than to thread width. CONCLUSIONS Stress in cancellous bone is more likely to be influenced by thread parameters than stress in cortical bone. A 45-degree BL force is more likely to be influenced by thread parameters than an axial force. A thread height of 0.34 to 0.50 mm and a thread width of 0.18 to 0.30 mm is optimal from a biomechanical point of view. In the design of a screw-type implant, thread height is more important than thread width for the reduction of stress within the bone.

[1]  O. Zienkiewicz The Finite Element Method In Engineering Science , 1971 .

[2]  Shuichi Nomura,et al.  Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. , 2004, Clinical oral implants research.

[3]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[4]  Brunski Jb Biomechanical considerations in dental implant design. , 1988 .

[5]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[6]  A K Patra,et al.  Guidelines for analysis and redesign of dental implants. , 1998, Implant dentistry.

[7]  L. Barbier,et al.  Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible. , 1997, The International journal of oral & maxillofacial implants.

[8]  F. Mante,et al.  Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. , 1998, The Journal of oral implantology.

[9]  O. Miyakawa,et al.  Influence of marginal bone resorption on stress around an implant--a three-dimensional finite element analysis. , 2005, Journal of oral rehabilitation.

[10]  D. Cochran,et al.  The scientific basis for and clinical experiences with Straumann implants including the ITI Dental Implant System: a consensus report. , 2000, Clinical oral implants research.

[11]  L. Rasmusson,et al.  The use of a conical fixture design for fixed partial prostheses. A preliminary report. , 1998, Clinical oral implants research.

[12]  R. Puers,et al.  Implant design and interface force transfer , 2004 .

[13]  L. Borchers,et al.  Three-dimensional Stress Distribution Around a Dental Implant at Different Stages of Interface Development , 1983, Journal of dental research.

[14]  H. Chun,et al.  Evaluation of design parameters of osseointegrated dental implants using finite element analysis. , 2002, Journal of oral rehabilitation.

[15]  S. Timoshenko,et al.  Theory of elasticity , 1975 .

[16]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.

[17]  I Naert,et al.  The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. , 2001, Clinical oral implants research.

[18]  Y Akagawa,et al.  A comparative evaluation of mandibular finite element models with different lengths and elements for implant biomechanics. , 1998, Journal of oral rehabilitation.

[19]  E. W. Collings,et al.  The physical metallurgy of titanium alloys , 1984 .

[20]  T Suetsugu,et al.  Two-dimensional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. , 1990, The Journal of oral implantology.

[21]  S D Cook,et al.  A Model for the Implant-Bone Interface Characteristics of Porous Dental Implants , 1982, Journal of dental research.

[22]  K Gotfredsen,et al.  Anchorage of titanium implants with different surface characteristics: an experimental study in rabbits. , 2000, Clinical implant dentistry and related research.

[23]  J. Kuiper,et al.  Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. , 1992, The Journal of prosthetic dentistry.

[24]  G. Liu,et al.  Finite element analysis of four thread-form configurations in a stepped screw implant. , 2004, Journal of oral rehabilitation.

[25]  John B. Brunski,et al.  In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface , 1999, Advances in dental research.

[26]  L Sennerby,et al.  Influence of variations in implant diameters: a 3- to 5-year retrospective clinical report. , 1999, The International journal of oral & maxillofacial implants.

[27]  H. Iplikçioğlu,et al.  Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. , 2002, Journal of dentistry.

[28]  W C Van Buskirk,et al.  Modeling the biomechanics of the mandible: a three-dimensional finite element study. , 1992, Journal of biomechanics.

[29]  S. Hansson,et al.  The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. , 2003, Journal of biomechanics.

[30]  Hom-Lay Wang,et al.  Dental Implant Design and Its Relationship to Long-Term Implant Success , 2003, Implant dentistry.

[31]  J Chen,et al.  Mechanical simulation of the human mandible with and without an endosseous implant. , 1994, Medical engineering & physics.

[32]  R. Puers,et al.  Implant design and interface force transfer. A photoelastic and strain-gauge analysis. , 2004, Clinical oral implants research.

[33]  I Lewinstein,et al.  Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis. , 1995, The International journal of oral & maxillofacial implants.

[34]  K J Anusavice,et al.  Three-dimensional finite element analysis of glass-ceramic dental crowns. , 1990, Journal of biomechanics.

[35]  M. Norton,et al.  Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure. , 1998, Clinical oral implants research.

[36]  J B Brunski Biomechanical considerations in dental implant design. , 1988, The International journal of oral implantology : implantologist.

[37]  R. Palmer,et al.  A prospective study of Astra single tooth implants. , 1997, Clinical oral implants research.

[38]  G Van der Perre,et al.  The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. , 1998, Clinical oral implants research.

[39]  F. Bosman,et al.  A comparison of three finite element models of an edentulous mandible provided with implants. , 1993, Journal of oral rehabilitation.

[40]  J B Brunski,et al.  Biomechanical factors affecting the bone-dental implant interface. , 1992, Clinical materials.

[41]  C. Misch Contemporary Implant Dentistry , 1993 .

[42]  Joel D. Bumgardner,et al.  Preliminary Evaluation of a New Dental Implant Design in Canine Models , 2000, Implant dentistry.