Flow and Heat Transfer in a Pre-Swirl Rotor-Stator System

Conditions in the internal-air system of a high-pressure turbine stage are modelled using a rig comprising an outer pre-swirl chamber separated by a seal from an inner rotor-stator system. Pre-swirl nozzles in the stator supply the “blade-cooling” air, which leaves the system via holes in the rotor, and disc-cooling air enters at the centre of the system and leaves through clearances in the peripheral seals. The experimental rig is instrumented with thermocouples, fluxmeters, pitot tubes and pressure taps enabling temperatures, heat fluxes, velocities and pressures to be measured at a number of radial locations.For rotational Reynolds numbers of Reϕ ≃ 1.2 × 106, the swirl ratio and the ratios of disc-cooling and blade-cooling flow rates are chosen to be representative of those found inside gas turbines. Measured radial distributions of velocity, temperature and Nusselt number are compared with computations obtained from an axisymmetric elliptic solver, featuring a low-Reynolds-number k-e turbulence model. For the inner rotor-stator system, the computed core temperatures and velocities are in good agreement with measured values, but the Nusselt numbers are underpredicted. For the outer pre-swirl chamber, it was possible to make comparisons between the measured and computed values for cooling-air temperatures but not for the Nusselt numbers. As expected, the temperature of the blade-cooling air decreases as the swirl ratio increases, but the computed air temperatures are significantly lower than the measured ones. Overall, the results give valuable insight into some of the heat transfer characteristics of this complex system.Copyright © 1995 by ASME

[1]  J. M. Owen,et al.  Computation of the flow and heat transfer due to a rotating disc , 1991 .

[2]  B.Meierhofer,et al.  An Investigation of a Preswirled cooling Airflow to a Turbine Disc by Measuring the Air Temperature in the Rotating Channels , 1981 .

[3]  吉田 豊明 1992 International Symposium on Heat Transfer in Turbomachinery , 1993 .

[4]  J. Owen,et al.  Heat transfer measurements in rotating-disc systems part 1: The free disc , 1988 .

[5]  S. Wittig,et al.  Local Heat Transfer in Turbine Disk-Cavities: Part II — Rotor Cooling With Radial Location Injection of Coolant , 1990 .

[6]  J. M. Owen,et al.  Flow and Heat Transfer in Rotating Disc Systems, Vol.1: Rotor-Stator Systems , 1989 .

[7]  Z. B. El-Oun,et al.  Preswirl Blade-Cooling Effectiveness in an Adiabatic Rotor–Stator System , 1989 .

[8]  J. Owen,et al.  Transitional flow between contra-rotating disks , 1994, Journal of Fluid Mechanics.

[9]  A. Morse Numerical Prediction of Turbulent Flow in Rotating Cavities , 1988 .

[10]  F. Staub Rotor Cavity Flow and Heat Transfer With Inlet Swirl and Radial Outflow of Cooling Air , 1992 .

[11]  G. H. Dibelius,et al.  Heat Transfer From a Rotating Disc , 1990 .

[12]  J. M. Owen,et al.  Flow and heat transfer in rotating-disc systems , 1994 .

[13]  S. Wittig,et al.  Local Heat Transfer in Turbine Disk Cavities: Part I—Rotor and Stator Cooling With Hub Injection of Coolant , 1992 .

[14]  B. Launder,et al.  Application of the energy-dissipation model of turbulence to the calculation of flow near a spinning disc , 1974 .

[15]  U. P. Phadke,et al.  Aerodynamic aspects of the sealing of gas-turbine rotor-stator systems , 1988 .