An Integrated Micromachined Thermopile Sensor With a Chopper Interface Circuit for Contact-Less Temperature Measurements

This paper presents a sensor and its readout circuit suitable for contact-less temperature measurements. The sensor, designed employing a MEMS technology provided by STMicroelectronics, consists of a miniaturized micromachined silicon thermopile with 180-V/W responsivity, 540- $\text{k}\Omega $ output resistance, and 0.64-mm2 active absorbing area. The interface circuit, fabricated in a standard 130-nm CMOS process, employs chopper technique in order to provide amplification of the sensor output signal, which behaves substantially as a DC while minimizing offset and noise contributions at low frequency. Given the sensor characteristics, a single-ended architecture was preferred over the most straightforward fully-differential approach. The interface circuit reduces the offset by a factor 255, achieving an input referred offset standard deviation equal to 1.365 $\mu \text{V}$ , measured across 29 samples. The thermopile sensor and the interface circuit, integrated in two separate test-chips, were characterized and extensively measured both as stand-alone devices and together as a system to perform contact-less temperature measurements. Adding a metal cap to the thermopile sensor in order to reduce the environmental noise, a measurement accuracy of approximately ±0.2 °C was obtained, thus verifying the system suitability for human body temperature detection.

[1]  D. Rowe Thermoelectrics Handbook , 2005 .

[2]  Tayfun Akin,et al.  An integrated thermopile structure with high responsivity using any standard CMOS process , 1997, International Conference on Solid-State Sensors, Actuators and Microsystems.

[3]  E. Ring,et al.  Human Body Temperature: Its Measurement and Regulation , 1982 .

[4]  A. Bakker,et al.  A CMOS nested-chopper instrumentation amplifier with 100-nV offset , 2000, IEEE Journal of Solid-State Circuits.

[5]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.

[6]  E. Vittoz,et al.  A CMOS Chopper Amplifier , 1986, ESSCIRC '86: Twelfth European Solid-State Circuits Conference.

[7]  Edoardo Bonizzoni,et al.  A Chopper Interface Circuit for Thermopile-Based Thermal Sensors , 2019, 2019 IEEE International Symposium on Circuits and Systems (ISCAS).

[8]  Massimo Piotto,et al.  A Chopper Instrumentation Amplifier With Input Resistance Boosting by Means of Synchronous Dynamic Element Matching , 2017, IEEE Transactions on Circuits and Systems I: Regular Papers.

[9]  J. D. Felske,et al.  Radiation Heat Transfer: A Statistical Approach , 2002 .

[10]  Kofi A. A. Makinwa,et al.  A 21 nV/$\surd$ Hz Chopper-Stabilized Multi-Path Current-Feedback Instrumentation Amplifier With 2 $\mu$ V Offset , 2012, IEEE Journal of Solid-State Circuits.

[11]  Qiuting Huang,et al.  A low-noise CMOS instrumentation amplifier for thermoelectric infrared detectors , 1997 .

[12]  Chengkuo Lee,et al.  CMOS Compatible Midinfrared Wavelength-Selective Thermopile for High Temperature Applications , 2015, Journal of Microelectromechanical Systems.

[13]  Vadim Ivanov,et al.  5.1 A 10MHz-bandwidth 4µs-large-signal-settling 6.5nV/√Hz-noise 2µV-offset chopper operational amplifier , 2016, 2016 IEEE International Solid-State Circuits Conference (ISSCC).

[14]  Tie Li,et al.  Robust Array-Composite Micromachined Thermopile IR Detector by CMOS Technology , 2011, IEEE Electron Device Letters.

[15]  Christian Menolfi,et al.  Uncooled low-cost thermal imager based on micromachined CMOS integrated sensor array , 2001 .

[16]  Chengkuo Lee,et al.  CMOS-based thermopiles using vertically integrated double polycrystalline silicon layers , 2013, 2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS).