Towards more efficient use of intravenous lumens in multi-infusion settings: development and evaluation of a multiplex infusion scheduling algorithm

Background Multi-drug intravenous (IV) therapy is one of the most common medical procedures used in intensive care units (ICUs), operating rooms, oncology wards and many other hospital departments worldwide. As drugs or their solvents are frequently chemically incompatible, many solutions must be administered through separate lumens. When the number of available lumens is too low to facilitate the safe administration of these solutions, additional (peripheral) IV catheters are often required, causing physical discomfort and increasing the risk for catheter related complications. Our objective was to develop and evaluate an algorithm designed to reduce the number of intravenous lumens required in multi-infusion settings by multiplexing the administration of various parenteral drugs and solutions. Methods A multiplex algorithm was developed that schedules the alternating IV administration of multiple incompatible IV solutions through a single lumen, taking compatibility-related, pharmacokinetic and pharmacodynamic constraints of the relevant drugs into account. The conventional scheduling procedure executed by ICU nurses was used for comparison. The number of lumens required by the conventional procedure (L CONV ) and multiplex algorithm (L MX ) were compared. Results We used data from 175,993 ICU drug combinations, with 2251 unique combinations received by 2715 consecutive ICU patients. The mean ± SD number of simultaneous IV solutions was 2.8 ± 1.6. In 27% of all drug combinations, and 61% of the unique combinations the multiplex algorithm required fewer lumens ( p  < 0.001). With increasing L CONV , the reduction in number of lumens by the multiplex algorithm further increased ( p  < 0.001). In only 1% of cases multiplexing required > 3 lm, versus 12% using the conventional procedure. Conclusion The multiplex algorithm addresses a major issue that occurs in ICUs, operating rooms, oncology wards, and many other hospital departments where several incompatible drugs are infused through a restricted number of lumens. The multiplex algorithm allows for more efficient use of IV lumens compared to the conventional multi-infusion strategy.

[1]  Soraya Dhillon,et al.  Basic pharmacokinetics , 2006 .

[2]  Ismael Ripoll,et al.  Period Selection for Minimal Hyperperiod in Periodic Task Systems , 2013, IEEE Transactions on Computers.

[3]  J. Amoore,et al.  Syringe pumps and start-up time: ensuring safe practice. , 2001, Nursing standard (Royal College of Nursing (Great Britain) : 1987).

[4]  D. Benhamou,et al.  Norepinephrine kinetics and dynamics in septic shock and trauma patients. , 2005, British journal of anaesthesia.

[5]  R. Mehta,et al.  Fluid overload in the ICU: evaluation and management , 2016, BMC Nephrology.

[6]  J. Meulenhoff,et al.  Koninklijke Nederlandse Maatschappij ter bevordering der Pharmacie , 1980, Pharmaceutisch Weekblad.

[7]  J. Brinkley,et al.  Resource utilization and cost of inserting peripheral intravenous catheters in hospitalized children. , 2013, Hospital pediatrics.

[8]  J. Rodríguez-Baño,et al.  Assessing the influence of risk factors on rates and dynamics of peripheral vein phlebitis: an observational cohort study. , 2012, Medicina clinica.

[9]  Dan M. Kluger,et al.  The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. , 2006, Mayo Clinic proceedings.

[10]  S. Chevret,et al.  Single- versus triple-lumen central catheter-related sepsis: a prospective randomized study in a critically ill population. , 1992, The American journal of medicine.

[11]  Vittorio Silano,et al.  A statement on the developmental immunotoxicity of bisphenol A (BPA): answer to the question from the Dutch Ministry of Health, Welfare and Sport , 2016, EFSA journal. European Food Safety Authority.

[12]  R. Snijder,et al.  Assessment of drug delivery devices , 2015, Biomedizinische Technik. Biomedical engineering.

[13]  Chung Laung Liu,et al.  Scheduling Algorithms for Multiprogramming in a Hard-Real-Time Environment , 1989, JACM.

[14]  J. Marshall,et al.  What is an intensive care unit? A report of the task force of the World Federation of Societies of Intensive and Critical Care Medicine , 2017, Journal of critical care.

[15]  J. Marshall,et al.  Conservative fluid management or deresuscitation for patients with sepsis or acute respiratory distress syndrome following the resuscitation phase of critical illness: a systematic review and meta-analysis , 2017, Intensive Care Medicine.

[16]  H. Isenberg,et al.  Central catheter infections: single- versus triple-lumen catheters. Influence of guide wires on infection rates when used for replacement of catheters. , 1988, The American journal of medicine.

[17]  M. Weiss,et al.  Start‐up delays of infusion syringe pumps , 2001, Paediatric anaesthesia.

[18]  Jacob S. Tripp,et al.  Reduction of peripherally inserted central catheter-associated DVT. , 2013, Chest.

[19]  Fokie Cnossen,et al.  Improved usability of a multi-infusion setup using a centralized control interface: A task-based usability test , 2017, PloS one.

[20]  E. Uslusoy,et al.  Predisposing factors to phlebitis in patients with peripheral intravenous catheters: A descriptive study , 2008, Journal of the American Academy of Nurse Practitioners.

[21]  J. Proost,et al.  MW/Pharm, an integrated software package for drug dosage regimen calculation and therapeutic drug monitoring. , 1992, Computers in biology and medicine.

[22]  James W. Layland,et al.  Scheduling Algorithms for Multiprogramming in a Hard-Real-Time Environment , 1989, JACM.

[23]  M. Nijsten,et al.  Quantitative assessment of required separator fluid volume in multi-infusion settings , 2020, The journal of vascular access.