Experimental study on temperature rise of acoustic radiation force elastography

IntroductionAcoustic radiation force (ARF) elastography is potentially useful for imaging the elasticity of human tissue. Because a “push wave” that is used to generate ARF is a long burst wave comparable to that used in regular clinical imaging, detailed investigation of its safety is required.Materials and methodsWe focus on the transient temperature rise in the far field, where the beam paths are overlapped. Soft tissue mimicking a phantom and bone samples were exposed to a 2-MHz plane wave for 20 s. The temperature rises in the far field were measured using a thermocouple. The temperature rises at 1 ms, the time required for the displacement measurement, were estimated by fitting the experimental results. The results showed that the thermosensitivity of the bone was 36 times higher than that of the phantom, and the use of a repeated push wave may have exceeded the allowable maximum temperature rise, 1°C, on the bone surface.ConclusionIn conclusion, the imaging area, including the path of the push wave, should be carefully checked and the time interval for consecutive use should be adjusted to prevent thermal risk on the surface of the bone.

[1]  Yoichiro Matsumoto,et al.  Polyacrylamide gel containing egg white as new model for irradiation experiments using focused ultrasound. , 2004, Ultrasound in medicine & biology.

[2]  J. Bamber,et al.  Ultrasound elasticity imaging: definition and technology , 1999, European Radiology.

[3]  Ian Rivens,et al.  Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field , 2008, Physics in medicine and biology.

[4]  K. Nightingale,et al.  On the thermal effects associated with radiation force imaging of soft tissue , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Takashi Azuma,et al.  Measurement of Elastic Properties of Tissue by Shear Wave Propagation Generated by Acoustic Radiation Force , 2010 .

[6]  G. Trahey,et al.  On the feasibility of remote palpation using acoustic radiation force. , 2001, The Journal of the Acoustical Society of America.

[7]  Armando Manduca,et al.  Imaging elastic properties of biological tissues by low-frequency harmonic vibration , 2003, Proc. IEEE.

[8]  William H. Press,et al.  Numerical Recipes 3rd Edition: The Art of Scientific Computing , 2007 .

[9]  Tsuyoshi Shiina,et al.  Real time tissue elasticity imaging using the combined autocorrelation method , 2002, Journal of Medical Ultrasonics.

[10]  S. Ueha,et al.  Tissue hardness measurement using the radiation force of focused ultrasound , 1990, IEEE Symposium on Ultrasonics.

[11]  J. Bamber,et al.  Evaluation of experimental methods for assessing safety for ultrasound radiation force elastography. , 2009, The British journal of radiology.

[12]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.

[13]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  K. Nightingale,et al.  Quantifying hepatic shear modulus in vivo using acoustic radiation force. , 2008, Ultrasound in medicine & biology.

[15]  Shahram Vaezy,et al.  Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy. , 2003, Ultrasound in medicine & biology.

[16]  椎名 毅 Tissue Elasticity Imaging , 1998 .

[17]  Wesley Le Mars Nyborg,et al.  11 - Acoustic Streaming , 1965 .

[18]  Joyce R. McLaughlin,et al.  Shear wave speed recovery in transient elastography and supersonic imaging using propagating fronts , 2006 .

[19]  J Ophir,et al.  On the use of envelope and RF signal decorrelation as tissue strain estimators. , 1997, Ultrasound in medicine & biology.

[20]  R C Preston,et al.  Proposed standard thermal test object for medical ultrasound. , 1999, Ultrasound in medicine & biology.

[21]  G. Trahey,et al.  Image quality, tissue heating, and frame rate trade-offs in acoustic radiation force impulse imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Najib N. Abboud,et al.  Electromechanical modeling using explicit time-domain finite elements , 1993 .

[23]  M. Fink,et al.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.