Design and control of a wind energy conversion system based on a resonant dc/dc converter

Recent wind energy harvesting technology development has focused on using dc collection and a possible smaller passive grid because of high energy efficient components in the converter system. This study evaluates and compares the hard-switched full bridge converter and the series–parallel LCC resonant converter, both with transformer coupling, and suitable for wind energy conversion system (WECS). Experimental results substantiate their merits and drawbacks in variable wind speed conditions. The unique, previously unexploited feature of the LCC resonant converter is increased gain at low output power, low speed and low input voltage. A hardware wind turbine simulator emulating an actual wind turbine is used, with its design and control briefly highlighted. This study demonstrates the feasibility of utilising an LCC resonant converter for WECS through simulation and experimental results, both at the same power level.

[1]  Robert W. Erickson,et al.  Comparison of resonant topologies in high-voltage DC applications , 1988 .

[2]  A.J. Gilbert,et al.  Normalized Analysis and Design of LCC Resonant Converters , 2007, IEEE Transactions on Power Electronics.

[3]  Stefan Lundberg,et al.  System efficiency of a DC/DC converter‐based wind farm , 2008 .

[4]  D. Divan,et al.  New high power DC-DC converter with loss limited switching and lossless secondary clamp , 2003 .

[5]  Dong-Wook Yoo,et al.  Novel zero-voltage and zero-current-switching full bridge PWM converter using transformer auxiliary winding , 2000 .

[6]  Martin F. Schlecht,et al.  A 1 kW, 500 kHz front-end converter for a distributed power supply system , 1989, Proceedings, Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[7]  F. Peng,et al.  An Alternative Energy Recovery Clamp Circuit for Full-Bridge PWM Converters With Wide Ranges of Input Voltage , 2008, IEEE Transactions on Power Electronics.

[8]  Yen-Shin Lai,et al.  Switching Control Technique of Phase-Shift-Controlled Full-Bridge Converter to Improve Efficiency Under Light-Load and Standby Conditions Without Additional Auxiliary Components , 2010, IEEE Transactions on Power Electronics.

[9]  Yoon-Ho Kim,et al.  An improved soft switching PWM FB DC/DC converter for reducing conduction losses , 1996 .

[10]  Lena Max,et al.  Design and control of a DC collection grid for a wind farm , 2009 .

[11]  A.J. Gilbert,et al.  Rapid design of LCC current-output resonant converters with reduced electrical stresses , 2005, 2005 European Conference on Power Electronics and Applications.

[12]  R. Steigerwald,et al.  A comparison of half-bridge resonant converter topologies , 1987, 1987 IEEE Applied Power Electronics conference and Exposition.

[13]  John E. Fletcher,et al.  One-power-point operation for variable speed wind/tidal stream turbines with synchronous generators , 2011 .

[14]  Ming-Chieh Tsai Analysis and implementation of a full-bridge constant-frequency LCC-type parallel resonant converter , 1994 .