Evaluating thermal comfort in mixed-mode buildings: A field study in a subtropical climate

Abstract To clarify the controversy about whether the adaptive comfort model is applicable in buildings with mechanical cooling systems operating in natural ventilation (NV) mode, we designed a longitudinal study in a mixed-mode (MM) building where mechanical air conditioning and natural passive cooling coexist in the same case building. Through statistical analysis of occupants' thermal responses during air conditioning (AC) and NV periods, considerable differences in occupants' perceived comfort were observed. The results show that occupants' actual thermal sensation and acceptance of thermal conditions both varied when the building changed from AC to NV mode, or vice versa. Compared to the steady-state comfort model (i.e., PMV), the adaptive model was found to be more applicable to MM buildings, especially when NV was being utilized. These findings provide support for a more flexible applicability of the adaptive comfort model in the real world, and can serve as a valuable reference for the design and operation of MM buildings.

[1]  Leslie K. Norford,et al.  Naturally ventilated and mixed-mode buildings—Part I: Thermal modeling , 2009 .

[2]  Per Heiselberg,et al.  Principles of hybrid ventilation. , 2002 .

[3]  Joseph Andrew Clarke,et al.  Using results from field surveys to predict the effect of open windows on thermal comfort and energy use in buildings , 2007 .

[4]  K. Tham,et al.  Priorities for ISIAQ in addressing climate change and sustainability challenges. , 2013, Indoor air.

[5]  Min Li,et al.  Can personal control influence human thermal comfort? A field study in residential buildings in China in winter , 2014 .

[6]  R. Dedear,et al.  Validation of the predicted mean vote model of thermal comfort in six Australian field studies , 1985 .

[7]  Hom B. Rijal,et al.  Understanding occupant behaviour: the use of controls in mixed-mode office buildings , 2009 .

[8]  Leslie K. Norford,et al.  Naturally ventilated and mixed-mode buildings—Part II: Optimal control , 2009 .

[9]  Yingxin Zhu,et al.  Using Natural Ventilation in Office Buildings Under Subtropical Climate: A case Study in Shenzhen , 2014 .

[10]  Richard de Dear,et al.  Mixed-mode buildings: A double standard in occupants’ comfort expectations , 2012 .

[11]  J D Hardy,et al.  Comfort and thermal sensations and associated physiological responses at various ambient temperatures. , 1967, Environmental research.

[12]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[13]  David Rowe,et al.  Thermal Comfort in a Naturally Ventilated Environment with Supplementary Cooling and Heating , 2004 .

[14]  Gail Brager,et al.  Occupant satisfaction in mixed-mode buildings , 2009 .

[15]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[16]  F. Nicol,et al.  Derivation of the adaptive equations for thermal comfort in free-running buildings in European standard EN15251 , 2010 .

[17]  Qinglin Meng,et al.  Thermal comfort in naturally ventilated buildings in hot-humid area of China , 2010 .

[18]  E. Halawa,et al.  The adaptive approach to thermal comfort: A critical overview , 2012 .

[19]  Scott Drake,et al.  Occupant comfort in naturally ventilated and mixed-mode spaces within air-conditioned offices , 2010 .

[20]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[21]  Povl Ole Fanger,et al.  Thermal comfort in the future - excellence and expectation , 2001 .

[22]  Gail Brager,et al.  Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 , 2002 .

[23]  Gail Brager,et al.  Mixed-mode cooling. , 2006 .

[24]  Y Zhu,et al.  Progress in thermal comfort research over the last twenty years. , 2013, Indoor air.

[25]  Q. Ouyang,et al.  Field study of human thermal comfort and thermal adaptability during the summer and winter in Beijing , 2011 .

[26]  R. Dear,et al.  Thermal adaptation in the built environment: a literature review , 1998 .

[27]  Steven J. Emmerich,et al.  Simulated Performance of Natural and Hybrid Ventilation Systems in an Office Building , 2006 .

[28]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[29]  Ryozo Ooka,et al.  Adaptive model of thermal comfort for offices in hot and humid climates of India , 2014 .