A new technique to measure interfacial tension of transformer oil using UV-Vis spectroscopy

Interfacial tension (IFT) and acid numbers of insulating oil are correlated with the number of years that a transformer has been in service and are used as a signal for transformer oil reclamation. Oil sampling for IFT measurement calls for extra precautions due to its high sensitivity to various oil parameters and environmental conditions. The current used technique to measure IFT of transformer oil is relatively expensive, requires an expert to conduct the test and it takes long time since the extraction of oil sample, sending it to external laboratory and getting the results back. This paper introduces a new technique to estimate the IFT of transformer oil using ultraviolet-to-visible (UV-Vis) spectroscopy. UV-Vis spectral response of transformer oil can be measured instantly with relatively cheap equipment, does not need an expert person to conduct the test and has the potential to be implemented online. Results show that there is a good correlation between oil spectral response and its IFT value. Artificial neural network (ANN) approach is proposed to model this correlation.

[1]  S. M. Islam,et al.  Significance of cellulose power transformer condition assessment , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  A. Abu-Siada,et al.  A review on chemical diagnosis techniques for transformer paper insulation degradation , 2013, 2013 Australasian Universities Power Engineering Conference (AUPEC).

[3]  H. Herman,et al.  On-site analysis of transformer paper insulation using portable spectroscopy for chemometric prediction of aged condition , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Raj Aggarwal,et al.  Statistical and neural network analysis of dissolved gases in power transformers , 2000 .

[5]  Harry Gumilang Unique relationship between interfacial tension test (IFT) and neutral number test (Acidity) of transformer insulation oil in PLN P3B JB - Jakarta and Banten Regional , 2009, 2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials.

[6]  T. Oommen Vegetable oils for liquid-filled transformers , 2002 .

[7]  A. Abu-Siada,et al.  A Novel Fuzzy-Logic Approach for Furan Estimation in Transformer Oil , 2012, IEEE Transactions on Power Delivery.

[8]  Chris W. Brown ULTRAVIOLET, VISIBLE, and NEAR-INFRARED SPECTROPHOTOMETERS , 2000 .

[9]  D. Skelly,et al.  Photo-acoustic spectroscopy for dissolved gas analysis: Benefits and Experience , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[10]  A.E.B. Abu-Elanien,et al.  Survey on the Transformer Condition Monitoring , 2007, 2007 Large Engineering Systems Conference on Power Engineering.

[11]  M A G Martins,et al.  Vegetable oils, an alternative to mineral oil for power transformers- experimental study of paper aging in vegetable oil versus mineral oil , 2010, IEEE Electrical Insulation Magazine.

[12]  Anders Krogh,et al.  Neural Network Ensembles, Cross Validation, and Active Learning , 1994, NIPS.

[13]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[14]  Shigemitsu Okabe,et al.  Inhibition technique of transformer insulating oil degradation - evaluation of the effectiveness of oxidation degradation inhibitors , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  Carlos Gershenson,et al.  Artificial Neural Networks for Beginners , 2003, ArXiv.

[16]  V. Miranda,et al.  Improving the IEC table for transformer failure diagnosis with knowledge extraction from neural networks , 2005, IEEE Transactions on Power Delivery.

[17]  C. S. Kalpage,et al.  Performance of coconut oil as an alternative transformer liquid insulation , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  A. Abu-Siada,et al.  A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  A. Abu-Siada,et al.  A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.

[20]  A. A. Siada,et al.  Effect of Conducting Materials on UV-Vis Spectral Response Characteristics , 2013 .

[21]  S Eeckhoudt,et al.  Applicability of methanol as new marker for paper degradation in power transformers , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  T. O. Rouse Mineral insulating oil in transformers , 1998 .

[23]  Hasmat Malik,et al.  Make use of UV/VIS spectrophotometer to determination of dissolved decay products in mineral insulating oils for transformer remnant life estimation with ANN , 2011, 2011 Annual IEEE India Conference.

[24]  A. H. El-Hag,et al.  Artificial neural networks with stepwise regression for predicting transformer oil furan content , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.