Application of response surface methodology for optimizing evacuation time in enclosed car park

Smoke fills the car park area due to smoke back layering occurred during a fire. The presence of the beam which leads to the smoke back layering phenomena is investigated to remain smoke layer longer at the upper level with fewer occurrences of backflow. In the current study, a combination of Design of Experiment (DOE); Central Composite Design, (CCD) and statistical tools Response Surface Methodology, (RSM) were utilised to evaluate an optimal design for longer smoke residing time. The Fire Dynamic Simulator (FDS), a CFD model for the fire-driven fluid flow, was employed as a flow simulation tool. The result of six replication model produced by DOE, the error that ranged from 0.48% to 1.77% indicating that the model is reliable. It was also found that the polynomial regression result was linear with predicted R2 of 97.64%, which was within the actual R2 (99.45%). The effects of five control parameters such as ceiling height, beam spacing, transversal beam, extraction rate and longitudinal beam on the smoke descend time has been found to be significant. In the optimal design, the smoke remained longer at the upper level with the percentage of improvement 217.95%. The contribution of the study is the time measured in this analysis is adequate within the beam span only. Interestingly, it effects to the overall geometry with having a lengthier time of smoke to descend. The polynomial model should be used for future engineering design in an enclosed car park.

[1]  Robert L Vettori Effect of beamed, sloped, and sloped beamed ceilings on the activation time of a residential sprinkler , 2003 .

[2]  Nils Johansson,et al.  Numerical experiments and compartment fires , 2014 .

[3]  Michael A. Delichatsios,et al.  The flow of fire gases under a beamed ceiling , 1981 .

[4]  Longhua Hu,et al.  A global model on temperature profile of buoyant ceiling gas flow in a channel with combining mass and heat loss due to ceiling extraction and longitudinal forced air flow , 2014 .

[5]  Douglas W. Hill,et al.  CFD Simulation of ventilation and smoke movement in a large military firing range , 2015 .

[6]  James G. Quintiere,et al.  Scale Model Reconstruction of Fire in an Atrium , 2008 .

[7]  Bart Merci,et al.  Smoke and heat control for fires in large car parks: Lessons learnt from research? , 2013 .

[8]  Haukur Ingason,et al.  Model scale tunnel fire tests with longitudinal ventilation , 2010 .

[9]  Jie Ji,et al.  An experimental investigation on thermal characteristics of sidewall fires in corridor-like structures with varying width , 2015 .

[10]  Mohd Tohir,et al.  Multiple Vehicle Design Fire Scenarios in Car Parking Buildings , 2015 .

[11]  Bart Merci,et al.  Smoke Control in Case of Fire in a Large Car Park: CFD Simulations of Full-scale Configurations , 2013 .

[12]  Omid Nematollahi,et al.  Reduction of energy consumption using passive architecture in hot and humid climates , 2015 .

[13]  Muhammad Agung Santoso,et al.  CFD Study on the Ventilation System and Shape Configuration of Underground Car Park in Case of Fire , 2015 .

[14]  Bart Merci,et al.  Smoke control in case of fire in a large car park: Full-scale experiments , 2013 .

[15]  Yu Wang,et al.  Numerical Study on Impulse Ventilation for Smoke Control in an Underground Car Park , 2011 .

[16]  Vahid Motevalli,et al.  Effect of Beams on Ceiling Jet Behavior and Heat Detector Operation , 1993 .

[17]  Bart Merci,et al.  On the extrapolation of CFD results for smoke and heat control in reduced-scale set-ups to full scale: atrium configuration , 2013 .

[18]  Vahid Motevalli,et al.  Steady State Ceiling Jet Behavior under an Unconfined Ceiling with Beams , 2008 .

[19]  John H. Klote The ASHRAE design manual for smoke control , 1984 .

[20]  V. Motevalli,et al.  Behavior Of A 2-dimensional Ceiling Jet Flow: A Beamed Ceiling Configuration , 1994 .

[21]  Chan Chau Siang CHARACTERIZING SMOKE DISPERSION ALONG BEAMED CEILINGS USING SALT-WATER MODELING , 2010 .