Ultrasensitive flow cytometric analyses

New techniques and approaches to cellular analysis are being developed at the Los Alamos National Flow Cytometry Resource. These developments can be divided into those that improve sensitivity through the implementation of new measurement techniques and those that move the technology into new areas by refining existing approaches. An example of the first category is a flow cytometric system being assembled that is capable of measuring the phase shift of fluorescence emitted by fluorophors bound to cells. This phase sensitive cytometer is capable of quantifying fluorescence life time on a cell-by-cell basis as well as using the phase sensitive detection to separate fluorescence emissions that overlap spectrally but have different lifetimes. A Fourier transform flow cytometer capable of measuring the fluorescence emission spectrum of individual labeled cells at rates approaching several hundred per second is also in the new technology category. The current implementation is capable of resolving the visible region of the spectrum into 8 bands. With this instrument, it is possible to resolve the contributions of fluorophors with overlapping emission spectra and to determine the emission spectra of dyes such as calcium concentration indicators that are sensitive to the physiological environment.

[1]  John A. Steinkamp,et al.  Resolution of heterogeneous fluorescence emission signals and decay-lifetime measurement of fluorochrome-labeled cells by phase-sensitive FCM , 1993, Photonics West - Lasers and Applications in Science and Engineering.

[2]  Steven A. Soper,et al.  Detection and identification of single molecules in solution , 1992 .

[3]  Richard A. Keller,et al.  Ultrasensitive detection of single molecules in flowing sample streams by laser-induced fluorescence , 1993, Photonics West - Lasers and Applications in Science and Engineering.

[4]  Mark Lewis Hammond,et al.  DNA sequencing by single molecule detection of labeled nucleotides sequentially cleaved from a single strand of DNA , 1993, Photonics West - Lasers and Applications in Science and Engineering.

[5]  J. Martin,et al.  Time: a new parameter for kinetic measurements in flow cytometry. , 1980, Science.

[6]  R. Keller,et al.  Single-molecule detection as an approach to rapid DNA sequencing. , 1992, Trends in biotechnology.

[7]  J A Steinkamp,et al.  Resolution of fluorescence signals from cells labeled with fluorochromes having different lifetimes by phase-sensitive flow cytometry. , 1993, Cytometry.

[8]  Richard A. Keller,et al.  Detection and lifetime measurement of single molecules in flowing sample streams by laser‐induced fluorescence , 1993 .

[9]  J H Jett,et al.  Amplified flow-cytometric separation-free fluorescence immunoassays. , 1985, Clinical chemistry.

[10]  S A BERSON,et al.  Immunoassay of endogenous plasma insulin in man. , 1996, The Journal of clinical investigation.