The relationship between specific absorption rate and temperature elevation in anatomically based human body models for plane wave exposure from 30 MHz to 6 GHz

According to the international safety guidelines/standard, the whole-body-averaged specific absorption rate (Poljak et al 2003 IEEE Trans. Electromagn. Compat. 45 141-5) and the peak spatial average SAR are used as metrics for human protection from whole-body and localized exposures, respectively. The IEEE standard (IEEE 2006 IEEE C95.1) indicates that the upper boundary frequency, over which the whole-body-averaged SAR is deemed to be the basic restriction, has been reduced from 6 to 3 GHz, because radio-wave energy is absorbed around the body surface when the frequency is increased. However, no quantitative discussion has been provided to support this description especially from the standpoint of temperature elevation. It is of interest to investigate the maximum temperature elevation in addition to the core temperature even for a whole-body exposure. In the present study, using anatomically based human models, we computed the SAR and the temperature elevation for a plane-wave exposure from 30 MHz to 6 GHz, taking into account the thermoregulatory response. As the primary result, we found that the ratio of the core temperature elevation to the whole-body-averaged SAR is almost frequency independent for frequencies below a few gigahertz; the ratio decreases above this frequency. At frequencies higher than a few gigahertz, core temperature elevation for the same whole-body averaged SAR becomes lower due to heat convection from the skin to air. This lower core temperature elevation is attributable to skin temperature elevation caused by the power absorption around the body surface. Then, core temperature elevation even for whole-body averaged SAR of 4 W kg(-1) with the duration of 1 h was at most 0.8 °C, which is smaller than a threshold considered in the safety guidelines/standard. Further, the peak 10 g averaged SAR is correlated with the maximum body temperature elevations without extremities and pinna over the frequencies considered. These findings were confirmed for seven models, including models of a child and a pregnant female. Thus, the current basic restriction for whole-body exposure in the international guidelines is conservative. Peak spatial-averaged SAR can be used as a metric for estimating local temperature elevation even for whole-body exposure. Our computational results also support the description in the IEEE standard about the reduction of the upper applicable frequency of whole-body-averaged SAR from 6 and 3 GHz; the power density reference level is more conservative than the basic restriction limit for the whole-body averaged SAR from the standpoint of temperature elevation.

[1]  O. Fujiwara,et al.  Correlation between maximum temperature increase and peak SAR with different average schemes and masses , 2006, IEEE Transactions on Electromagnetic Compatibility.

[2]  Jan A. J. Stolwijk,et al.  A mathematical model of physiological temperature regulation in man , 1971 .

[3]  Niels Kuster,et al.  The Virtual Family—development of surface-based anatomical models of two adults and two children for dosimetric simulations , 2010, Physics in medicine and biology.

[4]  S. Michaelson,et al.  Biological Effects and Health Hazards of RF and MW Energy: Fundamentals and Overall Phenomenology , 1983 .

[5]  A.W. Guy,et al.  Safety Level with Respect to Human Exposure to Radiofrequency Electromagnetic Fields (300 Khz-100 GHz) , 1980, 1980 IEEE MTT-S International Microwave symposium Digest.

[6]  P. Dimbylow FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz. , 1997, Physics in medicine and biology.

[7]  O. Fujiwara,et al.  Computational model for calculating body-core temperature elevation in rabbits due to whole-body exposure at 2.45 GHz , 2008, Physics in medicine and biology.

[8]  Yutaka Tochihara,et al.  Thermoregulation during heat exposure of young children compared to their mothers , 2004, European Journal of Applied Physiology and Occupational Physiology.

[9]  J. Wiart,et al.  Variability analysis of SAR from 20 MHz to 2.4 GHz for different adult and child models using finite-difference time-domain , 2008, Physics in medicine and biology.

[10]  T. Samaras,et al.  Influence of Thermophysiological Parameters on the Calculations of Temperature Rise in the Head of Mobile Phone Users , 2007, IEEE Transactions on Electromagnetic Compatibility.

[11]  Akimasa Hirata,et al.  Modeling time variation of blood temperature in a bioheat equation and its application to temperature analysis due to RF exposure , 2009, Physics in medicine and biology.

[12]  Dragan Poljak,et al.  Human equivalent antenna model for transient electromagnetic radiation exposure , 2003 .

[13]  Akimasa Hirata,et al.  Dominant factors affecting temperature rise in simulations of human thermoregulation during RF exposure , 2011, Physics in medicine and biology.

[14]  E. Adair,et al.  Thermoregulatory responses to RF energy absorption , 2003, Bioelectromagnetics.

[15]  Ilkka Laakso,et al.  Assessment of the computational uncertainty of temperature rise and SAR in the eyes and brain under far-field exposure from 1 to 10 GHz , 2009, Physics in medicine and biology.

[16]  O. Fujiwara,et al.  FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines , 2007, Physics in medicine and biology.

[17]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[18]  Paolo Bernardi,et al.  Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz range , 2003, IEEE Transactions on Biomedical Engineering.

[19]  P. Dimbylow,et al.  Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz. , 2002, Physics in medicine and biology.

[20]  J F Bakker,et al.  Children and adults exposed to electromagnetic fields at the ICNIRP reference levels: theoretical assessment of the induced peak temperature increase , 2011, Physics in medicine and biology.

[21]  Marvin C Ziskin,et al.  Thermal thresholds for teratogenicity, reproduction, and development , 2011, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[22]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[23]  R. Croft,et al.  SAR versus Sinc: What is the appropriate RF exposure metric in the range 1–10 GHz? Part I: Using planar body models , 2010, Bioelectromagnetics.

[24]  J. Herbertz Comment on the ICNIRP guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998, Health physics.

[25]  Niels Kuster,et al.  Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models , 2009, Physics in medicine and biology.

[26]  O. Fujiwara,et al.  Dominant factors influencing whole‐body average SAR due to far‐field exposure in whole‐body resonance frequency and GHz regions , 2007, Bioelectromagnetics.

[27]  K. Lomas,et al.  Computer prediction of human thermoregulatory and temperature responses to a wide range of environmental conditions , 2001, International journal of biometeorology.

[28]  Kenneth R Foster,et al.  Modeling thermal responses in human subjects following extended exposure to radiofrequency energy , 2004, Biomedical engineering online.

[29]  S Fujimoto,et al.  Studies on the physical surface area of Japanese. 18. Calculation formulas in three stages over all ages , 1968 .

[30]  O. Gandhi,et al.  Temperature distributions in the human leg for VLF-VHF exposures at the ANSI-recommended safety levels , 1988, IEEE Transactions on Biomedical Engineering.

[31]  R. Zaridze,et al.  Influence of Specific Absorption Rate Averaging Schemes on Correlation between Mass-Averaged Specific Absorption Rate and Temperature Rise , 2009 .

[32]  O. Fujiwara,et al.  FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure , 2008, Physics in medicine and biology.

[33]  T. Nagaoka,et al.  Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry. , 2004, Physics in medicine and biology.

[34]  A. Hirata,et al.  Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms , 2008, Physics in medicine and biology.

[35]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[36]  O. Fujiwara,et al.  The correlation between mass-averaged SAR and temperature elevation in the human head model exposed to RF near-fields from 1 to 6 GHz , 2009, Physics in medicine and biology.

[37]  Kazuyuki Saito,et al.  Temperature elevation in the fetus from electromagnetic exposure during magnetic resonance imaging , 2010, Physics in medicine and biology.

[38]  O. Fujiwara,et al.  ESTIMATION OF CORE TEMPERATURE ELEVATION IN HUMANS AND ANIMALS FOR WHOLE-BODY AVERAGED SAR , 2009 .

[39]  Theodoros Samaras,et al.  Worst Case Temperature Rise in a One-Dimensional Tissue Model Exposed to Radiofrequency Radiation , 2007, IEEE Transactions on Biomedical Engineering.

[40]  James D. Hardy,et al.  Basal Metabolism, Radiation, Convection and Vaporization at Temperatures of 22 to 35°C. Six Figures , 1938 .

[41]  Kenneth R. Holmes,et al.  MICROVASCULAR CONTRIBUTIONS IN TISSUE HEAT TRANSFER , 1980, Annals of the New York Academy of Sciences.

[42]  Soichi Watanabe,et al.  Proportion-corrected scaled voxel models for Japanese children and their application to the numerical dosimetry of specific absorption rate for frequencies from 30 MHz to 3 GHz. , 2008, Physics in medicine and biology.

[43]  I. Laakso,et al.  SAR variation study from 300 to 5000 MHz for 15 voxel models including different postures , 2010, Physics in medicine and biology.