A system for the analysis of foot and ankle kinematics during gait.

A five-camera Vicon (Oxford Metrics, Oxford, England) motion analysis system was used to acquire foot and ankle motion data. Static resolution and accuracy were computed as 0.86 +/- 0.13 mm and 98.9%, while dynamic resolution and accuracy were 0.1 +/- 0.89 and 99.4% (sagittal plane). Spectral analysis revealed high frequency noise and the need for a filter (6 Hz Butterworth low-pass) as used in similar clinical situations. A four-segment rigid body model of the foot and ankle was developed. The four rigid body foot model segments were 1) tibia and fibula, 2) calcaneus, talus, and navicular, 3) cuneiforms, cuboid, and metatarsals, and 4) hallux. The Euler method for describing relative foot and ankle segment orientation was utilized in order to maintain accuracy and ease of clinical application. Kinematic data from a single test subject are presented.

[1]  D A Winter,et al.  A three-dimensional musculoskeletal model for gait analysis. Anatomical variability estimates. , 1989, Journal of biomechanics.

[2]  J R Engsberg,et al.  A biomechanical analysis of the talocalcaneal joint--in vitro. , 1987, Journal of biomechanics.

[3]  King H. Yang,et al.  Relationship between lower limb dynamics and knee joint pain , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  A four-segment kinematic model for clinical description of foot and ankle motion , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  R. N. Stauffer,et al.  Force and motion analysis of the normal, diseased, and prosthetic ankle joint. , 1977, Clinical orthopaedics and related research.

[6]  D. Winter,et al.  Biomechanical model of the human foot: kinematics and kinetics during the stance phase of walking. , 1993, Journal of biomechanics.

[7]  Michael W. Whittle,et al.  Gait Analysis: An Introduction , 1986 .

[8]  M W Whittle Calibration and performance of a 3-dimensional television system for kinematic analysis. , 1982, Journal of biomechanics.

[9]  H. M. Karara,et al.  Direct Linear Transformation from Comparator Coordinates into Object Space Coordinates in Close-Range Photogrammetry , 2015 .

[10]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  R. W. Mann,et al.  A three-dimensional kinematic acquisition and intersegmental dynamic analysis system for human motion , 1985 .

[12]  S. M. Kidder,et al.  Development of a system for dynamic 3-D analysis of foot and ankle motion , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  D. Winter,et al.  Talocrural and talocalcaneal joint kinematics and kinetics during the stance phase of walking. , 1991, Journal of biomechanics.

[14]  G. E. Johnson,et al.  A kinematic model of the human ankle. , 1985, Journal of biomedical engineering.

[15]  M. Whittle,et al.  Initiation of gait in normal subjects: a preliminary study. , 1990, Journal of biomedical engineering.

[16]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[17]  A four-segment model for clinical description of foot and anide motion , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[19]  S. Õunpuu,et al.  Three-dimensional lower extremity joint kinetics in normal pediatric gait. , 1991, Journal of pediatric orthopedics.

[20]  S. Siegler,et al.  The three-dimensional kinematics and flexibility characteristics of the human ankle and subtalar joints--Part I: Kinematics. , 1988, Journal of biomechanical engineering.

[21]  A. Lundberg,et al.  Kinematics of the Ankle/Foot Complex: Plantarflexion and Dorsiflexion , 1989, Foot & ankle.

[22]  J. W. Humberston Classical mechanics , 1980, Nature.

[23]  J. Apkarian,et al.  A three-dimensional kinematic and dynamic model of the lower limb. , 1989, Journal of biomechanics.

[24]  R. Lyman Ott.,et al.  An introduction to statistical methods and data analysis , 1977 .

[25]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.