Towards lab-on-a-chip diagnostics for malaria elimination.

Malaria continues to be one of the most devastating diseases impacting global health. Although there have been significant reductions in global malaria incidence and mortality rates over the past 17 years, the disease remains endemic throughout the world, especially in low- and middle-income countries. The World Health Organization has put forth ambitious milestones moving toward a world free of malaria as part of the United Nations Millennium Goals. Mass screening and treatment of symptomatic and asymptomatic malaria infections in endemic regions is integral to these goals and requires diagnostics that are both sensitive and affordable. Lab-on-a-chip technologies provide a path toward sensitive, portable, and affordable diagnostic platforms. Here, we review and compare currently-available and emerging lab-on-a-chip diagnostic approaches in three categories: (1) protein-based tests, (2) nucleic acid tests, and (3) cell-based detection. For each category, we highlight the opportunities and challenges in diagnostics development for malaria elimination, and comment on their applicability to different phases of elimination strategies.

[1]  J. McCarthy,et al.  Sensitive Detection of Plasmodium vivax Using a High-Throughput, Colourimetric Loop Mediated Isothermal Amplification (HtLAMP) Platform: A Potential Novel Tool for Malaria Elimination , 2016, PLoS neglected tropical diseases.

[2]  D. Pillai,et al.  NINA-LAMP compared to microscopy, RDT, and nested PCR for the detection of imported malaria. , 2016, Diagnostic microbiology and infectious disease.

[3]  M. Saad Bhamla,et al.  Hand-powered ultralow-cost paper centrifuge , 2017, Nature Biomedical Engineering.

[4]  Seong Ho Kang,et al.  Fast on-site diagnosis of influenza A virus by Palm PCR and portable capillary electrophoresis. , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  Julien Reboud,et al.  Paper‐Origami‐Based Multiplexed Malaria Diagnostics from Whole Blood , 2016, Angewandte Chemie.

[6]  Subra Suresh,et al.  A microfabricated deformability-based flow cytometer with application to malaria. , 2011, Lab on a chip.

[7]  Jutamaad Satayavivad,et al.  Microfluidic approaches to malaria detection. , 2004, Acta tropica.

[8]  Charles R. Mace,et al.  Multiplexed, Patterned-Paper Immunoassay for Detection of Malaria and Dengue Fever. , 2016, Analytical chemistry.

[9]  J. McCarthy,et al.  A simple, high-throughput, colourimetric, field applicable loop-mediated isothermal amplification (HtLAMP) assay for malaria elimination , 2015, Malaria Journal.

[10]  Y. Li,et al.  Detection and species identification of malaria parasites by isothermal tHDA amplification directly from human blood without sample preparation. , 2013, The Journal of molecular diagnostics : JMD.

[11]  P. Searson,et al.  Nanoparticle-Based Histidine-Rich Protein-2 Assay for the Detection of the Malaria Parasite Plasmodium falciparum. , 2016, The American journal of tropical medicine and hygiene.

[12]  Yi-Ping Ho,et al.  Droplet microfluidics platform for highly sensitive and quantitative detection of malaria-causing Plasmodium parasites based on enzyme activity measurement. , 2012, ACS nano.

[13]  Boniface Namangala,et al.  Direct detection of falciparum and non-falciparum malaria DNA from a drop of blood with high sensitivity by the dried-LAMP system , 2017, Parasites & Vectors.

[14]  Rebecca Richards-Kortum,et al.  In vivo microscopy of hemozoin: towards a needle free diagnostic for malaria. , 2015, Biomedical optics express.

[15]  Mustafa Sarimollaoglu,et al.  In vivo photoacoustic flow cytometry for early malaria diagnosis , 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[16]  V. Zharov,et al.  Preclinical photoacoustic models: application for ultrasensitive single cell malaria diagnosis in large vein and artery. , 2016, Biomedical Optics Express.

[17]  C. Nair,et al.  Differential Diagnosis of Malaria on Truelab Uno®, a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications , 2016, PloS one.

[18]  Gerard L. Coté,et al.  Malaria Diagnosis Using a Mobile Phone Polarized Microscope , 2015, Scientific Reports.

[19]  Rebecca Richards-Kortum,et al.  Highly Sensitive Two-Dimensional Paper Network Incorporating Biotin-Streptavidin for the Detection of Malaria. , 2016, Analytical chemistry.

[20]  Jaber Aslanzadeh,et al.  Preventing PCR amplification carryover contamination in a clinical laboratory. , 2004, Annals of clinical and laboratory science.

[21]  L. Okell,et al.  Asymptomatic malaria infections: detectability, transmissibility and public health relevance , 2014, Nature Reviews Microbiology.

[22]  D. Alland,et al.  Detection of Mycobacterium tuberculosis in Blood by Use of the Xpert MTB/RIF Assay , 2013, Journal of Clinical Microbiology.

[23]  Parin Chaivisuthangkura,et al.  The development of loop‐mediated isothermal amplification combined with lateral flow dipstick for detection of Vibrio parahaemolyticus , 2011, Letters in applied microbiology.

[24]  Yoon-Bo Shim,et al.  A highly sensitive aptasensor towards Plasmodium lactate dehydrogenase for the diagnosis of malaria. , 2012, Biosensors & bioelectronics.

[25]  Paul Yager,et al.  Highly Sensitive Immunoassay Based on Controlled Rehydration of Patterned Reagents in a 2-Dimensional Paper Network , 2014, Analytical chemistry.

[26]  Yi-Ping Ho,et al.  Optimized Detection of Plasmodium falciparum Topoisomerase I Enzyme Activity in a Complex Biological Sample by the Use of Molecular Beacons , 2016, Sensors.

[27]  Weihua Guan,et al.  A field-deployable mobile molecular diagnostic system for malaria at the point of need. , 2016, Lab on a chip.

[28]  S. Liang,et al.  Development of Aptamer-Based Point-of-Care Diagnostic Devices for Malaria Using Three-Dimensional Printing Rapid Prototyping , 2016 .

[29]  Yen-Liang Liu,et al.  NanoCluster Beacons as reporter probes in rolling circle enhanced enzyme activity detection. , 2015, Nanoscale.

[30]  X. Su,et al.  Recent Progress in Functional Genomic Research in Plasmodium falciparum , 2010, Current genomics.

[31]  Ciara K. O´Sullivan,et al.  Ultrasensitive, rapid and inexpensive detection of DNA using paper based lateral flow assay , 2016, Scientific Reports.

[32]  Lisa Lafleur,et al.  Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards. , 2012, Lab on a chip.

[33]  Sehyun Shin,et al.  Magnetic separation of malaria-infected red blood cells in various developmental stages. , 2013, Analytical chemistry.

[34]  Westley S Bauer,et al.  Magnetically-enabled biomarker extraction and delivery system: towards integrated ASSURED diagnostic tools. , 2017, The Analyst.

[35]  P. Goswami,et al.  Development of an Indicator Displacement Based Detection of Malaria Targeting HRP-II as Biomarker for Application in Point-of-Care Settings. , 2016, Analytical chemistry.

[36]  Y. Yuthavong,et al.  Application of loop-mediated isothermal amplification assay combined with lateral flow dipstick for detection of Plasmodium falciparum and Plasmodium vivax. , 2014, Parasitology international.

[37]  E. Patsoula,et al.  A single-step, PCR-based method for the detection and differentiation of Plasmodium vivax and P. falciparum , 2003, Annals of tropical medicine and parasitology.

[38]  Hengyi Xu,et al.  Novel strategies to enhance lateral flow immunoassay sensitivity for detecting foodborne pathogens. , 2015, Journal of agricultural and food chemistry.

[39]  Hongshen Ma,et al.  Deformability based sorting of red blood cells improves diagnostic sensitivity for malaria caused by Plasmodium falciparum. , 2016, Lab on a chip.

[40]  Alongkorn Pimpin,et al.  The development of malaria diagnostic techniques: a review of the approaches with focus on dielectrophoretic and magnetophoretic methods , 2016, Malaria Journal.

[41]  S. Yanow Molecular Diagnosis of Malaria in Low-Resource Settings , 2016 .

[42]  Jaephil Do,et al.  An integrated disposable device for DNA extraction and helicase dependent amplification , 2010, Biomedical microdevices.

[43]  Thirumalaisamy P Velavan,et al.  A reliable and rapid method for molecular detection of malarial parasites using microwave irradiation and loop mediated isothermal amplification , 2014, Malaria Journal.

[44]  J. Sattabongkot,et al.  Nested PCR detection of malaria directly using blood filter paper samples from epidemiological surveys , 2014, Malaria Journal.

[45]  Kapaettu Satyamoorthy,et al.  New molecular detection methods of malaria parasites with multiple genes from genomes. , 2016, Acta tropica.

[46]  L. Robinson,et al.  Ultra-Sensitive Detection of Plasmodium falciparum by Amplification of Multi-Copy Subtelomeric Targets , 2015, PLoS medicine.

[47]  Nicholas M Adams,et al.  Automated Device for Asynchronous Extraction of RNA, DNA, or Protein Biomarkers from Surrogate Patient Samples , 2016, Journal of laboratory automation.

[48]  Y. Mori,et al.  Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. , 2001, Biochemical and biophysical research communications.

[49]  J. Moatti,et al.  Economic evaluation of point-of-care diagnostic technologies for infectious diseases. , 2010, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[50]  Zhiguo Qu,et al.  A fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection. , 2017, Lab on a chip.

[51]  T. Franke,et al.  Hydrodynamic lift of vesicles and red blood cells in flow--from Fåhræus & Lindqvist to microfluidic cell sorting. , 2014, Advances in colloid and interface science.

[52]  M. Littrell,et al.  Testing times: trends in availability, price, and market share of malaria diagnostics in the public and private healthcare sector across eight sub-Saharan African countries from 2009 to 2015 , 2017, Malaria Journal.

[53]  Clemens F Kaminski,et al.  Detection of Plasmodium falciparum-infected red blood cells by optical stretching. , 2010, Journal of biomedical optics.

[54]  Yang Jun Kang,et al.  High-Throughput and Label-Free Blood-on-a-Chip for Malaria Diagnosis. , 2016, Analytical chemistry.

[55]  S. S. Gorthi,et al.  Portable optofluidic absorption flow analyzer for quantitative malaria diagnosis from whole blood. , 2016, Applied optics.

[56]  George M Whitesides,et al.  "Paper Machine" for Molecular Diagnostics. , 2015, Analytical chemistry.

[57]  D. Wright,et al.  Simple sample processing enhances malaria rapid diagnostic test performance. , 2014, The Analyst.

[58]  R. Richards-Kortum,et al.  Emerging Nucleic Acid–Based Tests for Point-of-Care Detection of Malaria , 2012, The American journal of tropical medicine and hygiene.

[59]  M. Nadi,et al.  Use of an Insulation Layer on the Connection Tracks of a Biosensor with Coplanar Electrodes to Increase the Normalized Impedance Variation , 2019, Biosensors.

[60]  M. A. Diallo,et al.  Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites , 2016, Scientific Reports.

[61]  R. Richards-Kortum,et al.  Drop-to-drop variation in the cellular components of fingerprick blood: implications for point-of-care diagnostic development. , 2015, American journal of clinical pathology.

[62]  Weijia Wen,et al.  Extraction, amplification and detection of DNA in microfluidic chip-based assays , 2014, Microchimica Acta.

[63]  C. Nsanzabana Strengthening Surveillance Systems for Malaria Elimination by Integrating Molecular and Genomic Data , 2019, Tropical medicine and infectious disease.

[64]  Han Wei Hou,et al.  Deformability based cell margination--a simple microfluidic design for malaria-infected erythrocyte separation. , 2010, Lab on a chip.

[65]  D. Malamud,et al.  Improved assay to detect Plasmodium falciparum using an uninterrupted, semi-nested PCR and quantitative lateral flow analysis , 2013, Malaria Journal.

[66]  Venkatachalam Udhayakumar,et al.  Use of Malachite Green-Loop Mediated Isothermal Amplification for Detection of Plasmodium spp. Parasites , 2016, PloS one.

[67]  Gerry Killeen,et al.  “Asymptomatic” Malaria: A Chronic and Debilitating Infection That Should Be Treated , 2016, PLoS medicine.

[68]  C. Lim,et al.  Malaria detection using inertial microfluidics. , 2015, Lab on a chip.

[69]  Dionicia Gamboa,et al.  Analytical sensitivity of current best-in-class malaria rapid diagnostic tests , 2017, Malaria Journal.

[70]  C. Lim,et al.  Two-stage sample-to-answer system based on nucleic acid amplification approach for detection of malaria parasites. , 2016, Biosensors & bioelectronics.

[71]  David Bell,et al.  Development of new malaria diagnostics: matching performance and need , 2016, Malaria Journal.

[72]  Y. Huang,et al.  Introducing dielectrophoresis as a new force field for field-flow fractionation. , 1997, Biophysical journal.

[73]  R. Richards-Kortum,et al.  A paper and plastic device for the combined isothermal amplification and lateral flow detection of Plasmodium DNA , 2015, Malaria Journal.

[74]  A. Mbonye,et al.  Willingness-to-pay for a rapid malaria diagnostic test and artemisinin-based combination therapy from private drug shops in Mukono district, Uganda , 2012, Health policy and planning.

[75]  Jongyoon Han,et al.  Micromagnetic resonance relaxometry for rapid label-free malaria diagnosis , 2014, Nature Medicine.

[76]  William A. Mcmillan,et al.  Technology for automated, rapid, and quantitative PCR or reverse transcription-PCR clinical testing. , 2005, Clinical chemistry.

[77]  I. Bogoch,et al.  Evaluation of Malaria Diagnoses Using a Handheld Light Microscope in a Community-Based Setting in Rural Côte d'Ivoire. , 2016, The American journal of tropical medicine and hygiene.

[79]  Jongyoon Han,et al.  Enhancing malaria diagnosis through microfluidic cell enrichment and magnetic resonance relaxometry detection , 2015, Scientific Reports.

[80]  Benjamin M Wu,et al.  Single-step, paper-based concentration and detection of a malaria biomarker. , 2015, Analytica chimica acta.

[81]  F. Bier,et al.  Rapid detection of Plasmodium falciparum with isothermal recombinase polymerase amplification and lateral flow analysis , 2014, Malaria Journal.

[82]  C. Ban,et al.  A colorimetric aptasensor for the diagnosis of malaria based on cationic polymers and gold nanoparticles. , 2013, Analytical biochemistry.

[83]  Wenfeng Liang,et al.  Optoelectrokinetics-based microfluidic platform for bioapplications: A review of recent advances. , 2019, Biomicrofluidics.

[84]  N. Langeland,et al.  Comparison of four methods for extracting DNA from dried blood on filter paper for PCR targeting the mitochondrial Plasmodium genome , 2014, Transactions of the Royal Society of Tropical Medicine and Hygiene.

[85]  Evans Duah,et al.  Diagnosis of Schistosoma haematobium infection with a mobile phone-mounted Foldscope and a reversed-lens CellScope in Ghana. , 2015, The American journal of tropical medicine and hygiene.

[86]  M. Tanner,et al.  Defining the next generation of Plasmodium vivax diagnostic tests for control and elimination: Target product profiles , 2017, PLoS neglected tropical diseases.

[87]  Julian A. Tanner,et al.  Structural basis for discriminatory recognition of Plasmodium lactate dehydrogenase by a DNA aptamer , 2013, Proceedings of the National Academy of Sciences.

[88]  Ming-Chun Huang,et al.  Rapid electrochemical detection on a mobile phone. , 2013, Lab on a chip.

[89]  U. d’Alessandro,et al.  Molecular-based isothermal tests for field diagnosis of malaria and their potential contribution to malaria elimination , 2014, The Journal of antimicrobial chemotherapy.

[90]  Frederick F Becker,et al.  Microsample preparation by dielectrophoresis: isolation of malaria. , 2002, Lab on a chip.

[91]  Peter Chiodini,et al.  Thermal Contrast Amplification Reader Yielding 8-Fold Analytical Improvement for Disease Detection with Lateral Flow Assays. , 2016, Analytical chemistry.

[92]  Yi-Ping Ho,et al.  Refined Method for Droplet Microfluidics-Enabled Detection of Plasmodium falciparum Encoded Topoisomerase I in Blood from Malaria Patients , 2015 .

[93]  C. Wongsrichanalai,et al.  A review of malaria diagnostic tools: microscopy and rapid diagnostic test (RDT). , 2007, The American journal of tropical medicine and hygiene.

[94]  Arnab Sarkar,et al.  A portable rotating disc as blood rheometer. , 2019, Biomicrofluidics.

[95]  A. Mårtensson,et al.  Short report: Rapid DNA extraction from archive blood spots on filter paper for genotyping of Plasmodium falciparum. , 2005, The American journal of tropical medicine and hygiene.

[96]  R. Howes,et al.  Malaria diagnosis for malaria elimination , 2015, Current opinion in infectious diseases.

[97]  Daniel Malamud,et al.  An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases. , 2011, The Analyst.

[98]  Eiichi Honda,et al.  Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. , 2009, BioTechniques.

[99]  Subra Suresh,et al.  Quantitative Biomechanics of Healthy and Diseased Human Red Blood Cells using Dielectrophoresis in a Microfluidic System. , 2014, Extreme Mechanics Letters.

[100]  Paul Yager,et al.  Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection. , 2012, Analytical chemistry.

[101]  M. Wahlgren,et al.  Label-free microfluidic enrichment of ring-stage Plasmodium falciparum-infected red blood cells using non-inertial hydrodynamic lift , 2014, Malaria Journal.

[102]  A. Rai,et al.  A smartphone dongle for diagnosis of infectious diseases at the point of care , 2015, Science Translational Medicine.

[103]  Jeremy D. DeBarry,et al.  Applied Genomics: Data Mining Reveals Species-Specific Malaria Diagnostic Targets More Sensitive than 18S rRNA , 2011, Journal of Clinical Microbiology.

[104]  Rajan Dewar,et al.  A fully integrated paperfluidic molecular diagnostic chip for the extraction, amplification, and detection of nucleic acids from clinical samples. , 2016, Lab on a chip.

[105]  Sai Siva Gorthi,et al.  Optofluidic single‐cell absorption flow analyzer for point‐of‐care diagnosis of malaria , 2016, Journal of biophotonics.

[106]  David J. You,et al.  Cell-phone-based measurement of TSH using Mie scatter optimized lateral flow assays. , 2013, Biosensors & bioelectronics.

[107]  A lab-on-chip for malaria diagnosis and surveillance , 2014, Malaria Journal.

[108]  E. Arango,et al.  Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples , 2011, Malaria Journal.

[109]  Joshua D. Swartz,et al.  Low-resource method for extracting the malarial biomarker histidine-rich protein II to enhance diagnostic test performance. , 2012, Analytical chemistry.

[110]  D. Pillai,et al.  Evaluation of non-instrumented nucleic acid amplification by loop-mediated isothermal amplification (NINA-LAMP) for the diagnosis of malaria in Northwest Ethiopia , 2015, Malaria Journal.