Dosimetry of Exposure of Patients to Pulsed Gradient Magnetic Fields in MRI

In magnetic resonance imaging, time-varied gradient magnetic fields may stimulate nerves and muscles by inducing electric fields and currents in patients, which may potentially cause health problem. In this study, realistic transverse x-, y-gradient coils and longitudinal z-gradient coil were numerically designed. The magnetic flux density, current density and electric fields in a 3-D real human man model were calculated by employing impedance method. The exposure levels have been compared with the guidelines of the International Commission on Non-Ionizing Radiation Protection (ICNIRP). It was found that the spatially averaged magnetic flux density greatly exceeds the ICNIRP reference level, and the maximum value of the 1-cm2-averaged induced current density in central nervous system greatly exceeds the ICNIRP basic restriction. The strongest levels of exposure are observed when all three gradient coils are operated simultaneously.

[1]  D Andreuccetti,et al.  Influence of the surface averaging procedure of the current density in assessing compliance with the ICNIRP low-frequency basic restrictions by means of numerical techniques , 2009, Physics in medicine and biology.

[2]  M. Persson,et al.  Calculating the Current Density and Electric Field in Human Head by Multichannel Transcranial Magnetic Stimulation , 2009, IEEE Transactions on Magnetics.

[3]  Stuart Crozier,et al.  Exposure of workers to pulsed gradients in MRI , 2007, Journal of magnetic resonance imaging : JMRI.

[4]  J. Hajnal,et al.  Numerically‐simulated induced electric field and current density within a human model located close to a z‐gradient coil , 2007, Journal of magnetic resonance imaging : JMRI.

[5]  Maria A. Stuchly,et al.  Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging , 2004, IEEE Transactions on Biomedical Engineering.

[6]  J D Bourland,et al.  Review of Patient Safety in Time‐Varying Gradient Fields , 2000, Journal of magnetic resonance imaging : JMRI.

[7]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[8]  O. Gandhi,et al.  A 3-D impedance method to calculate power deposition in biological bodies subjected to time varying magnetic fields , 1988, IEEE Transactions on Biomedical Engineering.

[9]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[10]  K. Cole,et al.  Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics , 1941 .

[11]  Jmb Jan Kroot Analysis of eddy currents in a gradient coil , 2006 .

[12]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .