A hand biomechanics workstation

Interactive graphics for hand surgery was used to apply mathematical modeling and describe the kinematics of the hand and its resultant effect on hand function. Dynamic high resolution displays and three-dimensional images were tailored for use with a specific patients' hand and a new and powerful design and analysis tool produced. Methods were developed to portray kinematic information such as muscle excursion and effective moment arm and extended to yield dynamic information such as torque and work. This prototype workstation has been developed in concert with leading orthopedic surgeons and therapists.

[1]  K. An,et al.  Tendon excursion and moment arm of index finger muscles. , 1983, Journal of biomechanics.

[2]  J. Landsmeer Studies in the anatomy of articulation. I. The equilibrium of the "intercalated" bone. , 1961, Acta morphologica Neerlando-Scandinavica.

[3]  P. Brand,et al.  Relative tension and potential excursion of muscles in the forearm and hand. , 1981, The Journal of hand surgery.

[4]  Landsmeer Jm Studies in the anatomy of articulation. I. The equilibrium of the "intercalated" bone. , 1961 .

[5]  Loyd M. Myers,et al.  A Graphics Editor for 3-D CT-Scan Data for Musculo-Skeletal Modeling , 1987 .

[6]  Ali A. Seireg,et al.  Interactive Computer Modeling of the Musculoskeletal System , 1977, IEEE Transactions on Biomedical Engineering.

[7]  S. Simon,et al.  Computer-aided simulation, analysis, and design in orthopedic surgery. , 1986, The Orthopedic clinics of North America.

[8]  Michael W. Vannier,et al.  Three dimensional computer graphics for craniofacial surgical planning and evaluation , 1983, SIGGRAPH.

[9]  B M Hillberry,et al.  Piecewise mathematical representation of articular surfaces. , 1979, Journal of biomechanics.

[10]  Paul W. Brand,et al.  Clinical mechanics of the hand , 1985 .

[11]  M W Vannier,et al.  Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. , 1984, Radiology.

[12]  M. Schlindwein,et al.  THREE-DIMENSIONAL DISPLAY OF HUMAN ORGANS FROM COMPUTED TOMOGRAMS , 1979 .

[13]  K N An,et al.  Normative model of human hand for biomechanical analysis. , 1979, Journal of biomechanics.

[14]  John E. Howland,et al.  Computer graphics , 1990, IEEE Potentials.

[15]  D E Thompson,et al.  A kinematic model of the flexor tendons of the hand. , 1989, Journal of biomechanics.

[16]  Parvati Dev A Simulator for the Analysis of Wrist Position Control , 1982, 1982 American Control Conference.

[17]  A. Flatt,et al.  Biomechanical factors in the replacement of rheumatoid finger joints. , 1969, Annals of the rheumatic diseases.

[18]  G. Herman,et al.  Three-dimensional reconstruction of craniofacial deformity using computed tomography. , 1983, Neurosurgery.

[19]  Michael L. Rhodes,et al.  Systems Integration for the Manufacturing of Custom Protheses and Anatomic Models , 1987 .