Evaluating calibration strategies for isotope ratio infrared spectroscopy for atmospheric 13 CO 2 / 12 CO 2 measurement

Abstract. Isotope ratio infrared spectroscopy (IRIS) provides an in situ technique for measuring δ13C in atmospheric CO2. A number of methods have been proposed for calibrating the IRIS measurements, but few studies have systematically evaluated their accuracy for atmospheric applications. In this study, we carried out laboratory and ambient measurements with two commercial IRIS analyzers and compared the accuracy of four calibration strategies. We found that calibration based on the 12C and 13C mixing ratios (Bowling et al., 2003) and on linear interpolation of the measured delta using the mixing ratio of the major isotopologue (Lee et al., 2005) yielded accuracy better than 0.06‰. Over a 7-day atmospheric measurement in Beijing, the two analyzers agreed to within −0.02 ± 0.18‰ after proper calibration. However, even after calibration the difference between the two analyzers showed a slight correlation with concentration, and this concentration dependence propagated through the Keeling analysis, resulting in a much larger difference of 2.44‰ for the Keeling intercept. The high sensitivity of the Keeling analysis to the concentration dependence underscores the challenge of IRIS for atmospheric research.

[1]  W. Eugster,et al.  Continuous field measurements of δ13C–CO2 and trace gases by FTIR spectroscopy , 2008, Isotopes in environmental and health studies.

[2]  D. Griffith,et al.  A Fourier transform infrared trace gas and isotope analyser for atmospheric applications , 2012 .

[3]  Samuel Hammer,et al.  Assessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations , 2012 .

[4]  T. Hiyama,et al.  Observation of carbon and oxygen isotopic compositions of CO2 at an urban site in Nagoya using Mid-IR laser absorption spectroscopy , 2011 .

[5]  Hans-Georg Frede,et al.  Biodegradability screening of soil amendments through coupling of wavelength-scanned cavity ring-down spectroscopy to multiple dynamic chambers. , 2011, Rapid communications in mass spectrometry : RCM.

[6]  N. McDowell,et al.  13C content of ecosystem respiration is linked to precipitation and vapor pressure deficit , 2002, Oecologia.

[7]  J. Ehleringer,et al.  Inferring biogenic and anthropogenic carbon dioxide sources across an urban to rural gradient , 2007, Oecologia.

[8]  C. Yapp,et al.  Stable carbon isotope constraints on mixing and mass balance of CO2 in an urban atmosphere: Dallas metropolitan area, Texas, USA , 2003 .

[9]  Jianping Huang,et al.  A meta‐analysis of water vapor deuterium‐excess in the midlatitude atmospheric surface layer , 2012 .

[10]  Livio Gianfrani,et al.  Advances in laser-based isotope ratio measurements: selected applications , 2008 .

[11]  D. Worthy,et al.  Evaluation of a cavity ring-down spectrometer for in situ observations of 13 CO 2 , 2012 .

[12]  M. Litvak,et al.  Adaptation of continuous-flow cavity ring-down spectroscopy for batch analysis of δ13C of CO2 and comparison with isotope ratio mass spectrometry. , 2011, Rapid communications in mass spectrometry : RCM.

[13]  J. Y. King,et al.  Feasibility of quantifying ecosystem–atmosphere C18O16O exchange using laser spectroscopy and the flux-gradient method , 2005 .

[14]  A. Knohl,et al.  Eddy covariance measurements of CO2 isotopologues with a quantum cascade laser absorption spectrometer , 2012 .

[15]  X. Lee,et al.  Continuous measurement of water vapor D/H and 18 O/ 16 O isotope ratios in the atmosphere , 2008 .

[16]  John M. Baker,et al.  Measuring field-scale isotopic CO2 fluxes with tunable diode laser absorption spectroscopy and micrometeorological techniques , 2004 .

[17]  Colm Sweeney,et al.  High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air , 2012 .

[18]  Quantum cascade laser based spectrometer for in situ stable carbon dioxide isotope measurements , 2008 .

[19]  A. Knohl,et al.  Application of a quantum cascade laser-based spectrometer in a closed chamber system for real-time δ13C and δ18O measurements of soil-respired CO2 , 2011 .

[20]  H. Tanimoto,et al.  Effect of air composition (N 2 , O 2 , Ar, and H 2 O) on CO 2 and CH 4 measurement by wavelength-scanned cavity ring-down spectroscopy: calibration and measurement strategy , 2012 .

[21]  P. Werle Accuracy and precision of laser spectrometers for trace gas sensing in the presence of optical fringes and atmospheric turbulence , 2011 .

[22]  P. Koch,et al.  Isotopic Study of the Biology of Modern and Fossil Vertebrates , 2008 .

[23]  J. Welker,et al.  Progress and challenges in using stable isotopes to trace plant carbon and water relations across scales , 2012 .

[24]  Jed O. Kaplan,et al.  The application and interpretation of Keeling plots in terrestrial carbon cycle research , 2003 .

[25]  John M. Baker,et al.  Direct measurement of biosphere‐atmosphere isotopic CO2 exchange using the eddy covariance technique , 2008 .

[26]  X. Lee,et al.  Intercomparison of four commercial analyzers for water vapor isotope measurement , 2012 .

[27]  P. Werle,et al.  Signal processing and calibration procedures for in situ diode-laser absorption spectroscopy. , 2004, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[28]  J. Grace,et al.  Photosynthetic carbon isotope discrimination and its relationship to the carbon isotope signals of stem, soil and ecosystem respiration. , 2010, The New phytologist.

[29]  Manish X. Gupta,et al.  Deployment of a carbon isotope ratiometer for the monitoring of CO2 sequestration leakage. , 2011, Analytical chemistry.

[30]  Steven D. Sargent,et al.  Tunable diode laser absorption spectroscopy for stable isotope studies of ecosystem–atmosphere CO2 exchange , 2003 .

[31]  X. Lee,et al.  In Situ Measurement of the Water Vapor 18O/16O Isotope Ratio for Atmospheric and Ecological Applications , 2005 .

[32]  A. Körtzinger,et al.  Toward continuous monitoring of seawater 13CO2/12CO2 isotope ratio and pCO2: Performance of cavity ringdown spectroscopy and gas matrix effects , 2010 .

[33]  C. Wagner-Riddle,et al.  Use of the isotope flux ratio approach to investigate the C 18 O 16 O and 13 CO 2 exchange near the floor of a temperate deciduous forest , 2011 .

[34]  S. Guillon,et al.  Using a laser-based CO2 carbon isotope analyser to investigate gas transfer in geological media , 2012 .