SENSE: Sensitivity encoding for fast MRI

New theoretical and practical concepts are presented for considerably enhancing the performance of magnetic resonance imaging (MRI) by means of arrays of multiple receiver coils. Sensitivity encoding (SENSE) is based on the fact that receiver sensitivity generally has an encoding effect complementary to Fourier preparation by linear field gradients. Thus, by using multiple receiver coils in parallel scan time in Fourier imaging can be considerably reduced. The problem of image reconstruction from sensitivity encoded data is formulated in a general fashion and solved for arbitrary coil configurations and k‐space sampling patterns. Special attention is given to the currently most practical case, namely, sampling a common Cartesian grid with reduced density. For this case the feasibility of the proposed methods was verified both in vitro and in vivo. Scan time was reduced to one‐half using a two‐coil array in brain imaging. With an array of five coils double‐oblique heart images were obtained in one‐third of conventional scan time. Magn Reson Med 42:952–962, 1999. © 1999 Wiley‐Liss, Inc.

[1]  Allen Klinger Approximate pseudoinverse solutions to ill-conditioned linear systems , 1968 .

[2]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[3]  J. Haselgrove,et al.  An algorithm for compensation of surface-coil images for sensitivity of the surface coil , 1986 .

[4]  M. Hutchinson,et al.  Fast MRI data acquisition using multiple detectors , 1988, Magnetic resonance in medicine.

[5]  P. Narayana,et al.  Correction for intensity falloff in surface coil magnetic resonance imaging. , 1988, Medical physics.

[6]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[7]  S. Einav,et al.  A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. , 1991, Medical physics.

[8]  Jong Beom Ra,et al.  Fast imaging method using multiple receiver coils with subencoding data set , 1991 .

[9]  J B Ra,et al.  Fast imaging using subencoding data sets from multiple detectors , 1993, Magnetic resonance in medicine.

[10]  J W Murakami,et al.  Intensity correction of phased‐array surface coil images , 1996, Magnetic resonance in medicine.

[11]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[12]  Peter Boesiger,et al.  Spiral SENSE : Sensitivity Encoding with arbitrary K-space Trajectories , 1999 .

[13]  Peter Boesiger,et al.  Coil Sensitivity Encoding for Fast MRI , 2022 .