In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring

For reliable and economic long-term operation of Small Modular Reactors (SMR), it is imperative that continuous in-situ monitoring of critical equipment must be developed and incorporated in the reactor design phase. This capability is attractive for remote deployment of SMRs with longer fuel cycle duration and for minimizing forced outages, thus enhancing the utilization of these power generating systems in small electric grid environments. These issues were highlighted in a report on Instrumentation, Controls, and Human-Machine Interface Technology Development Roadmap for Grid Appropriate Reactors (ORNL). The DOE Workshops on On-Line Monitoring and Small Modular Reactors (held in June 2010) further emphasized the need for the development of continuous non-invasive approach for reactor surveillance. These technologies contribute to smart condition-based maintenance, reduced human resources, and remote monitoring of reactor components. In integral primary system reactors (IPSR) and other designs of SMRs, the pressure vessel incorporates most of the critical equipment used for power generation. Examples of such plant components include: motors, coolant circulation pumps, motor-operated valves, solenoid-operated valves, compressors, control rod drives, incore instrumentation, and reactor internal structures.

[1]  R.B. Perez,et al.  Structural integrity monitoring of steam generator tubing using transient acoustic signal analysis , 2005, IEEE Transactions on Nuclear Science.

[2]  D. A. Casada,et al.  The use of the motor as a transducer to monitor system conditions , 1996 .

[3]  J. Reyes,et al.  NuScale Plant Safety in Response to Extreme Events , 2012 .

[4]  H. D. Haynes Evaluation of check valve monitoring methods , 1992 .

[5]  C. N. Obiozor Selection of motor operated valves (MOV'S) for nuclear power plant application , 1995, Proceedings IEEE Southeastcon '95. Visualize the Future.

[6]  L. E. Conway,et al.  The IRIS Spool-Type Reactor Coolant Pump , 2002 .

[7]  Belle R. Upadhyaya,et al.  Advanced Instrumentation and Control Methods for Small and Medium Reactors with IRIS Demonstration , 2011 .

[8]  Masoud Naghedolfeizi,et al.  Dynamic Modeling of a Pressurized Water Reactor Plant for Diagnostics and Control , 1990 .

[9]  J. R. Rosenberg,et al.  The Fourier approach to the identification of functional coupling between neuronal spike trains. , 1989, Progress in biophysics and molecular biology.

[10]  B. R. Upadhyaya,et al.  An automated system for motor-operated valve diagnostics , 1991 .

[11]  R. C. Kryter,et al.  Condition monitoring of machinery using motor current signature analysis , 1989 .

[12]  Daniel T Ingersoll,et al.  Deliberately Small Reactors and the Second Nuclear Era , 2009 .

[13]  Jamie B. Coble,et al.  Applying the General Path Model to Estimation of Remaining Useful Life , 2011, International Journal of Prognostics and Health Management.

[14]  D. M. Eissenberg Status of motor operated valves aging assessment , 1989 .

[15]  Michael Eric Sharp,et al.  Prognostic Approaches Using Transient Monitoring Methods , 2012 .

[16]  H. D. Haynes Application of signature analysis for determining the operational readiness of motor-operated valves under blowdown test conditions , 1990 .

[17]  H. D. Haynes Electrical signature analysis (ESA) developments at the Oak Ridge Diagnostics Applied Research Center , 1995 .

[18]  Jeong Hwan Seo,et al.  A Rotordynamic Analysis Model for Rotor Shaft of SMART MCP , 1999 .

[19]  H. D. Haynes Recent improvements in check valve monitoring methods , 1991 .

[20]  H. M. Hashemian,et al.  Wireless sensors for predictive maintenance of rotating equipment in research reactors , 2011 .

[21]  W. M. Carey,et al.  Digital spectral analysis: with applications , 1986 .

[22]  J. J. Jelovich,et al.  A Fault Tolerant Multiplexed Control Rod Position Detection and Indication System for Nuclear Power Plants , 1977, IEEE Transactions on Nuclear Science.

[23]  Stan T. Shiels Centrifugal Pump Application - Key Hydraulic And Performance Criteria , 1995 .

[24]  D. Casada Using the motor to monitor pump conditions , 1996 .

[25]  Belle R. Upadhyaya,et al.  Multivariate statistical signal processing technique for fault detection and diagnostics , 1990 .

[26]  Leon M. Tolbert,et al.  Simulink implementation of induction machine model - a modular approach , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..