A Priority-Based Synchronous Phasor Transmission Protocol Extension Method for the Active Distribution Network

With the advancement of active distribution network construction, to solve the shortcomings of the existing distribution network technology in distribution network perception and control, the relevant technologies of the Wide Area Measurement System (WAMS) in the transmission network have attracted more attention in terms of their usage in the distribution network. Micro Multifunction Phasor Measurement Unit (μMPMU), as an example, is being gradually utilized in the distribution network. However, the existing synchronous phasor transmission protocol is mainly designed for the transmission network, which requires an extension to meet the communication requirements to be directly used in the distribution network. In this work, the requirements of active distribution network communication are analyzed, and trade-offs between National Standard of the People’s Republic of China/Recommended (GB/T) 26865.2-2011 and International Electro technical Commission (IEC) 60870-5-101/104 protocol are compared. An extension method of the communication protocol is proposed, with the benefits of the prioritized transmission of important data, expanded remote control function of μMPMU, increased types of offline files, and reduced amount of network communication and data storage. The method is built upon the existing GB/T 26865.2-2011 protocol, and refers to the Application Service Data Unit (ASDU) of IEC 60870-5-101/104 to add an application extension frame. Application extension frames are used to transmit telemetry data, telesignalization, partial commands, and partial offline files. Finally, an experimental environment is set up, which includes a phasor measurement unit (PMU) Emulator, distribution network phasor data concentrator (PDC), and main station emulator to implement the standard GB/T 26865.2-2011 protocol and extension protocol. The feasibility and effectiveness of the method are confirmed by the superior performance of the extended protocol compared with the standard protocol.

[1]  Guo Zhizhong A PRACTICAL PLACEMENT OF PMU IN WAMS COMPLEMENTAL TO SCADA AND DATA PROCESSING METHOD , 2005 .

[2]  Mohammad Shahidehpour,et al.  Synchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art , 2014, IEEE Access.

[3]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[4]  Timothy C. Green,et al.  Real-World MicroGrids-An Overview , 2007, 2007 IEEE International Conference on System of Systems Engineering.

[5]  Ping Ling,et al.  Comparison of IEEE C37.118.2-2011 standard and GB/T 26865.2-2011 standard based on synchrophasor data transfer , 2017, 2017 IEEE Conference on Energy Internet and Energy System Integration (EI2).

[6]  Salman Mohagheghi,et al.  Phasor measurement units for the distribution grid: Necessity and benefits , 2013, 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT).

[7]  Muhidin Lelic,et al.  Current trends on applications of PMUs in distribution systems , 2013, 2013 IEEE PES Innovative Smart Grid Technologies Conference (ISGT).

[8]  S. Morozumi,et al.  Micro-grid Demonstration Projects in Japan , 2007, 2007 Power Conversion Conference - Nagoya.

[9]  Hossein Lotfi,et al.  State of the Art in Research on Microgrids: A Review , 2015, IEEE Access.

[10]  Ahmad Khonsari,et al.  An effective countermeasure against traffic analysis attacks in wide area measurement systems , 2015, Inf. Syst..

[11]  Han Fukun Online Estimation of Transformer Parameters Based on PMU Measurements , 2011 .

[12]  Sun Yuanzhang Data Compatibility Analysis of WAMS/SCADA Hybrid Measurements State Estimation , 2010 .

[13]  Bill Rose,et al.  Microgrids , 2018, Smart Grids.

[14]  N. Hatziargyriou,et al.  Microgrids: an overview of ongoing research, development, anddemonstration projects , 2007 .

[15]  Z. A. Styczynski,et al.  Experience with PMUs in industrial distribution networks , 2010, IEEE PES General Meeting.

[16]  Ping Ling,et al.  Discussion and Reflection on the Application of IEEE C37.118.2-2011 Standard in Distribution Grids , 2018, 2018 2nd IEEE Advanced Information Management,Communicates,Electronic and Automation Control Conference (IMCEC).

[17]  Z. A. Styczynski,et al.  Usage of phasor measurement units for industrial applications , 2011, 2011 IEEE Power and Energy Society General Meeting.

[18]  Fang Zhang,et al.  Application of a real-time data compression and adapted protocol technique for WAMS , 2015, 2015 IEEE Power & Energy Society General Meeting.

[19]  Jarmo Aho,et al.  Active distribution network — Demonstration project ADINE , 2010, 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe).

[20]  Per Hallberg,et al.  Active distribution system management , 2013 .

[21]  Bo Zhao,et al.  Present and future development trend of active distribution network , 2014 .

[22]  Zhong Chen,et al.  Adaptive communication resource allocation for wide area measurement system , 2015, 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[23]  M. Wache,et al.  Application of Synchrophasor Measurements for distribution networks , 2011, 2011 IEEE Power and Energy Society General Meeting.

[24]  He Qings An Analysis Method for Business Sectional Flow of Distribution Communication Network , 2014 .

[25]  Malini Ghosal,et al.  Fusion of Multirate Measurements for Nonlinear Dynamic State Estimation of the Power Systems , 2019, IEEE Transactions on Smart Grid.

[26]  Huang Sheng Analysis on the demand for communication services in smart distribution network and communication technical scheme , 2010 .