Oxygen‐sensitive contrast in blood for steady‐state free precession imaging

Steady‐state free precession (SSFP) methods have gained widespread recognition for their ability to provide fast scans at high signal‐to‐noise ratio. This paper demonstrates that such methods are also capable of reflecting functional information, particularly blood oxygenation state. It is well known that SSFP signals show substantial sensitivity to small off‐resonance frequency variations. However, that mechanism cannot explain the oxygen‐sensitive contrast in blood that was observed with steady‐state methods using phase‐cycled radiofrequency pulses. From theoretical and experimental models it is demonstrated that the mechanism responsible for such contrast originates from the motion of spins through local field inhomogeneities in and around deoxygenated red blood cells. In addition, this work shows that it is critical to choose the scan parameters carefully for robust oxygen‐sensitive contrast. Finally, it is demonstrated that it is possible to build a quantitative model that incorporates the Luz–Meiboom model, which had been used in the past to estimate quantitative measures of vascular blood oxygen levels. It is envisioned that this method could be instrumental in real‐time imaging focused on detecting diseases where the oxygen state of blood is impaired. Magn Reson Med 53:574–583, 2005. © 2005 Wiley‐Liss, Inc.

[1]  H. S. Gutowsky,et al.  SPIN-ECHO STUDIES OF CHEMICAL EXCHANGE. II. CLOSED FORMULAS FOR TWO SITES. , 1965, The Journal of chemical physics.

[2]  R. Mason,et al.  Oxygen tension mapping with F‐19 echo‐planar MR imaging of sequestered perfluorocarbon , 1994, Journal of magnetic resonance imaging : JMRI.

[3]  G. Radda,et al.  Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. , 1982, Biochimica et biophysica acta.

[4]  J. Pauly,et al.  Characterization and reduction of the transient response in steady‐state MR imaging , 2001, Magnetic resonance in medicine.

[5]  H. Carr STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE , 1958 .

[6]  G. Wright,et al.  Optimized spiral imaging for measurement of myocardial T2 relaxation , 2003, Magnetic resonance in medicine.

[7]  A. Guyton,et al.  Human Physiology and Mechanisms of Disease , 1982 .

[8]  R M Henkelman,et al.  Water dynamics in human blood via combined measurements of T2 relaxation and diffusion in the presence of gadolinium , 1998, Magnetic resonance in medicine.

[9]  R M Henkelman,et al.  Integrated analysis of diffusion and relaxation of water in blood , 1998, Magnetic resonance in medicine.

[10]  K. Scheffler,et al.  Is TrueFISP a gradient‐echo or a spin‐echo sequence? , 2003, Magnetic resonance in medicine.

[11]  S. H. Koenig,et al.  Transverse relaxation of solvent protons induced by magnetized spheres: Application to ferritin, erythrocytes, and magnetite , 1987, Magnetic resonance in medicine.

[12]  A. Wilman,et al.  Vessel contrast at three Tesla in time-of-flight magnetic resonance angiography of the intracranial and carotid arteries. , 2002, Magnetic resonance imaging.

[13]  S. Meiboom,et al.  Nuclear Magnetic Resonance Study of the Protolysis of Trimethylammonium Ion in Aqueous Solution—Order of the Reaction with Respect to Solvent , 1963 .

[14]  R. Henkelman,et al.  Practical Implementation and Optimization of One‐shot T1 imaging , 1991, Magnetic resonance in medicine.

[15]  Albert Macovski,et al.  Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T , 1991 .

[16]  C. Gasparovic,et al.  The line shapes of the water proton resonances of red blood cells containing carbonyl hemoglobin, deoxyhemoglobin, and methemoglobin: implications for the interpretation of proton MRI at fields of 1.5 T and below. , 1990, Magnetic resonance imaging.

[17]  J Hennig,et al.  Detection of BOLD changes by means of a frequency‐sensitive trueFISP technique: preliminary results , 2001, NMR in biomedicine.

[18]  B R Rosen,et al.  Improving MR quantification of regional blood volume with intravascular T1 contrast agents: Accuracy, precision, and water exchange , 1996, Magnetic resonance in medicine.

[19]  Kensuke Sekihara,et al.  Steady-State Magnetizations in Rapid NMR Imaging Using Small Flip Angles and Short Repetition Intervals , 1987, IEEE Transactions on Medical Imaging.

[20]  H. S. Gutowsky,et al.  Spin—Echo NMR Studies of Chemical Exchange. I. Some General Aspects , 1964 .

[21]  H. S. Gutowsky,et al.  Spin‐Echo NMR Studies of Chemical Exchange. IV. Intramolecular Exchange of a Coupled AB System , 1965 .

[22]  E R McVeigh,et al.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T , 1998, Magnetic resonance in medicine.

[23]  F G Shellock,et al.  Radiofrequency Energy‐Induced Heating During MR Procedures: A Review , 2000, Journal of magnetic resonance imaging : JMRI.