The frequency content of gait.

We address amplification of noise in double differentiation of position histories for dynamic analysis of gait. Measurements of the frequency domain characteristics of signal and noise are required to quantitatively assess errors in raw, filtered, and dynamic gait data. The results of a simple technique to determine the frequency content of gait using a population of 12 subjects and a total of 30 gait records is presented.

[1]  R. W. Mann,et al.  A three-dimensional kinematic acquisition and intersegmental dynamic analysis system for human motion , 1985 .

[2]  H Lanshammar,et al.  On practical evaluation of differentiation techniques for human gait analysis. , 1982, Journal of biomechanics.

[3]  R. P. Wells,et al.  Assessment of signal and noise in the kinematics of normal, pathological and sporting gaits. , 1980 .

[4]  Mann Rw,et al.  Gait analysis--precise, rapid, automatic, 3-D position and orientation kinematics and dynamics. , 1983 .

[5]  S. Simon,et al.  Peak dynamic force in human gait. , 1981, Journal of biomechanics.

[6]  A. Voloshin,et al.  Force wave transmission through the human locomotor system. , 1981, Journal of biomechanical engineering.

[7]  L. Klenerman,et al.  Skeletal transients on heel strike in normal walking with different footwear. , 1980, Journal of biomechanics.

[8]  Aurelio Cappozzo,et al.  Analysis by hybrid computer of ground reactions in walking , 1974 .

[9]  R M Alexander,et al.  Fourier analysis of forces exerted in walking and running. , 1980, Journal of biomechanics.

[10]  R Van Audekercke,et al.  Methods, difficulties and inaccuracies in the study of human joint kinematics and pathokinematics by the instant axis concept. Example: the knee joint. , 1979, Journal of biomechanics.

[11]  J C Pezzack,et al.  An assessment of derivative determining techniques used for motion analysis. , 1977, Journal of biomechanics.

[12]  D A Winter,et al.  Measurement and reduction of noise in kinematics of locomotion. , 1974, Journal of biomechanics.

[13]  H. Lanshammar On precision limits for derivatives numerically calculated from noisy data. , 1982, Journal of biomechanics.

[14]  J Mizrahi,et al.  In-vivo elastic and damping response of the human leg to impact forces. , 1982, Journal of biomechanical engineering.

[15]  A. Cappozzo,et al.  The interplay of muscular and external forces in human ambulation. , 1976, Journal of biomechanics.

[16]  P. Dierckx,et al.  Calculation of derivatives and Fouriercoefficients of human motion data, while using spline functions. , 1979, Journal of biomechanics.

[17]  Kennan T. Smith Calculation of Derivatives , 1983 .

[18]  S. D. Stearns,et al.  Digital Signal Analysis , 1976, IEEE Transactions on Systems, Man, and Cybernetics.

[19]  A Pedotti,et al.  A general computing method for the analysis of human locomotion. , 1975, Journal of biomechanics.

[20]  H Hatze,et al.  The use of optimally regularized Fourier series for estimating higher-order derivatives of noisy biomechanical data. , 1981, Journal of biomechanics.

[21]  R. Mann,et al.  Gait analysis--precise, rapid, automatic, 3-D position and orientation kinematics and dynamics. , 1983, Bulletin of the Hospital for Joint Diseases Orthopaedic Institute.