Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology

Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.

[1]  Russel Torah,et al.  Dispenser printed capacitive proximity sensor on fabric for applications in the creative industries , 2016 .

[2]  George G. Malliaras,et al.  Direct patterning of organic conductors on knitted textiles for long-term electrocardiography , 2015, Scientific Reports.

[3]  Jan O. Borchers,et al.  Grabrics: A Foldable Two-Dimensional Textile Input Controller , 2016, CHI Extended Abstracts.

[4]  Eduardo García-Breijo,et al.  Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings , 2012 .

[5]  Gert Cauwenberghs,et al.  Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[6]  P. Tarjan,et al.  An ultra-high common-mode rejection ratio (CMRR) AC instrumentation amplifier for laplacian electrocardiographic measurement. , 1999, Biomedical instrumentation & technology.

[7]  Dong-Ki Kim,et al.  A Touchpad for Force and Location Sensing , 2010 .

[8]  Eduardo García-Breijo,et al.  A comparative analysis of printing techniques by using an active concentric ring electrode for bioelectrical recording , 2015 .

[9]  T. Hasbroucq,et al.  Spatial enhancement of EEG traces by surface Laplacian estimation: comparison between local and global methods , 2005, Clinical Neurophysiology.

[10]  Peter P. Tarjan,et al.  Optimization Of Multi-ring Sensing Electrode Set , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Mirza Mansoor Baig,et al.  A comprehensive survey of wearable and wireless ECG monitoring systems for older adults , 2013, Medical & Biological Engineering & Computing.

[12]  Javier Garcia-Casado,et al.  Feasibility and Analysis of Bipolar Concentric Recording of Electrohysterogram with Flexible Active Electrode , 2014, Annals of Biomedical Engineering.

[13]  Tse Nga Ng,et al.  Stretchable Dry Electrodes with Concentric Ring Geometry for Enhancing Spatial Resolution in Electrophysiology , 2017, Advanced healthcare materials.

[14]  G. Prats-Boluda,et al.  Development of a portable wireless system for bipolar concentric ECG recording , 2015 .

[15]  Robert Puers,et al.  Towards the integration of textile sensors in a wireless monitoring suit , 2004 .

[16]  J. Wikswo,et al.  Volume conductor effects on the spatial resolution of magnetic fields and electric potentials from gastrointestinal electrical activity , 2006, Medical and Biological Engineering and Computing.

[17]  T. Trung,et al.  Flexible and Stretchable Physical Sensor Integrated Platforms for Wearable Human‐Activity Monitoringand Personal Healthcare , 2016, Advanced materials.

[18]  B. Hjorth An on-line transformation of EEG scalp potentials into orthogonal source derivations. , 1975, Electroencephalography and clinical neurophysiology.

[19]  Michael T. Otley,et al.  PEDOT:PSS "Wires" Printed on Textile for Wearable Electronics. , 2016, ACS applied materials & interfaces.

[20]  Walter G. Besio,et al.  Analysis of Skin-Electrode Impedance Using Concentric Ring Electrode , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  Jyh-Yeong Chang,et al.  Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement , 2011, IEEE Transactions on Biomedical Engineering.

[22]  O. Makeyev,et al.  Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes. , 2016, Measurement : journal of the International Measurement Confederation.

[23]  Comparison of bipolar vs. tripolar concentric ring electrode Laplacian estimates , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  Christophe Bernard,et al.  High-performance transistors for bioelectronics through tuning of channel thickness , 2015, Science Advances.

[25]  Yiyao Ye-Lin,et al.  Wireless sensor node for non-invasive high precision electrocardiographic signal acquisition based on a multi-ring electrode , 2017 .

[26]  Lei Ding,et al.  Computation of Surface Laplacian for tri-polar ring electrodes on high-density realistic geometry head model , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[27]  K.-P. Hoffmann,et al.  Long-Term Characterization of Electrode Materials for Surface Electrodes in Biopotential Recording , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  C. O’Mahony,et al.  Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes , 2016 .

[29]  T. Itoh,et al.  Wearable Keyboard Using Conducting Polymer Electrodes on Textiles , 2016, Advanced materials.

[30]  Xiong Yu,et al.  Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review , 2016, IEEE Sensors Journal.

[31]  V. C. Padaki,et al.  Smart Vest: wearable multi-parameter remote physiological monitoring system. , 2008, Medical engineering & physics.

[32]  Carmen C. Y. Poon,et al.  Unobtrusive Sensing and Wearable Devices for Health Informatics , 2014, IEEE Transactions on Biomedical Engineering.

[33]  Willis J. Tompkins,et al.  Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database , 1986, IEEE Transactions on Biomedical Engineering.

[34]  Sang-Hoon Lee,et al.  CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring , 2012, IEEE Transactions on Biomedical Engineering.

[35]  W. Besio,et al.  Tripolar Laplacian electrocardiogram and moment of activation isochronal mapping , 2007, Physiological measurement.

[36]  G. Prats-Boluda,et al.  Towards the clinical use of concentric electrodes in ECG recordings: influence of ring dimensions and electrode position , 2016 .

[37]  Thomas Lonjaret,et al.  Cutaneous Recording and Stimulation of Muscles Using Organic Electronic Textiles , 2016, Advanced healthcare materials.

[38]  A. Kargov,et al.  Comparison of surface EMG monitoring electrodes for long-term use in rehabilitation device control , 2009, 2009 IEEE International Conference on Rehabilitation Robotics.

[39]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[40]  Oleksandr Makeyev,et al.  High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes , 2014, IEEE Journal of Translational Engineering in Health and Medicine.

[41]  C. Hertleer,et al.  Fabric sensors for the measurement of physiological parameters , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[42]  Bin He,et al.  On the Estimation of the Laplacian Electrocardiogram during Ventricular Activation , 1999, Annals of Biomedical Engineering.

[43]  J. J. Carr,et al.  Introduction to Biomedical Equipment Technology , 1981 .

[44]  Heinrich Planck,et al.  Sensory baby vest for the monitoring of infants , 2006, International Workshop on Wearable and Implantable Body Sensor Networks (BSN'06).