Natural History and Predictors of Temporary Epicardial Pacemaker Wire Function in Patients after Open Heart Surgery

Study Objectives: To assess the short-term reliability of temporary epicardial pacing wires in patients after open heart surgery and to determine the influence of preoperative factors on the performance of these wires. Patients and Methods: In this prospective, longitudinal cohort study, 60 patients (41 men) with a mean age of 66.8 ± 8.9 years were studied for 5.3 ± 1.1 days postoperatively. Each patient’s history, physical findings, hemodynamics and echocardiographic data were analyzed. Postoperatively, capture threshold, the electrogram amplitude and slew rate, and the lead impedance were determined daily in both chambers. Results: Both atrial and ventricular thresholds increased significantly (p < 0.001) by the 4th postoperative day. The P-wave amplitudes were consistently less than half of the R-wave amplitudes. Both P- and R-wave amplitudes deteriorated significantly by the 2nd postoperative day (p < 0.001 and p < 0.02, respectively). Atrial and ventricular slew rates and lead impedance decreased significantly during the observation period (p < 0.002). Conclusion: Although both atrial and ventricular temporary epicardial leads are reliable for short-term use, their function deteriorates on a daily basis. Perioperative factors are generally not helpful in predicting the performance of temporary epicardial pacing wires.

[1]  A. Liebold,et al.  Performance of Temporary Epicardial Stainless Steel Wire Electrodes Used to Treat Atrial Fibrillation: A Study in Patients Following Open Heart Surgery , 1999, Pacing and clinical electrophysiology : PACE.

[2]  A. Liebold,et al.  Low-energy cardioversion with epicardial wire electrodes: new treatment of atrial fibrillation after open heart surgery. , 1998, Circulation.

[3]  T. Treasure,et al.  Pacing thresholds of temporary epicardial electrodes: variation with electrode type, time, and epicardial position. , 1994, The Annals of thoracic surgery.

[4]  J. Cox,et al.  Temporary external DDD pacing after cardiac operations. , 1991, The Annals of thoracic surgery.

[5]  A. Camm,et al.  Pacing Modalities for Tachycardia Termination , 1990, Pacing and clinical electrophysiology : PACE.

[6]  S. Wallenhaupt,et al.  Intraoperative use of dual-chamber demand pacemakers for open heart operations. , 1989, The Annals of thoracic surgery.

[7]  P. Nido,et al.  Temporary Epicardial Pacing after Open Heart Surgery: Complications and Prevention , 1989, Journal of cardiac surgery.

[8]  M. M. Brown,et al.  Profile of patients requiring the use of epicardial pacing wires after coronary artery bypass surgery. , 1987, Heart & lung : the journal of critical care.

[9]  F. C. Himmler,et al.  Physiological Pacing: Present Status and Future Developments , 1987, Pacing and clinical electrophysiology : PACE.

[10]  F. Robicsek A method to place temporary atrial pacing electrodes during heart surgery. , 1983, The Thoracic and cardiovascular surgeon.

[11]  A. Arís,et al.  Clinical evaluation of a new temporary pacemaker wire. , 1983, Annals of Thoracic Surgery.

[12]  N. Kouchoukos,et al.  Use of temporarily placed epicardial atrial wire electrodes for the diagnosis and treatment of cardiac arrhythmias following open-heart surgery. , 1978, The Journal of thoracic and cardiovascular surgery.

[13]  R. Wallace,et al.  A critical look at temporary ventricular pacing following cardiac surgery. , 1977, Surgery.

[14]  N. Mills,et al.  Experience with atrial pacemaker wires implanted during cardiac operations. , 1973, The Journal of thoracic and cardiovascular surgery.

[15]  J. Kastor,et al.  Variations in discharge rate of demand pacemakers not due to malfunction. , 1970, The American journal of cardiology.