[Resistance analyses for recirculated membrane bioreactor].

The resistance analyses for recirculated membrane bioreactor by the resistance-in-series model and the modified gel-polarization model respectively were extended to the turbulent ultrafiltration system. The experiments are carried out by dye wastewater in a tubular membrane module, it is found that the permeate fluxes are predicted very well by these models for turbinate systems. And the resistance caused by the concentration polarization is studied; the gel layer resistance is the most important of all the resistances.