Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice.

ST-segment measurements in the standard 12-lead electrocardiogram (ECG) of patients with acute coronary syndromes are crucial for these patients' management. Our objective was to determine whether the 12-lead ECG derived from the 3-lead EASI system can attain a level of diagnostic performance similar to that of the Mason-Likar (ML) 12-lead ECG acquired in clinical practice (CP) by paramedics and emergency department technicians. Using 120-lead body surface potential maps recorded before and during balloon inflation angioplasty from 88 patients (divided into "responders" and "nonresponders"), and electrode placement data from 60 applications of precordial leads in CP, we generated for the "nonischemic" and "ischemic" states of each patient the following lead sets: the ML 12-lead ECG, the EASI-derived 12-lead ECG, and 60 sets of 12-lead CP ECGs. We extracted ST deviations at J + 60 milliseconds, summed them for all 12 leads of each lead set to obtain SigmaST, and, by using the bootstrap method, determined the mean sensitivity and specificity for recognizing the "ischemic" state at various thresholds of SigmaST. Results were displayed as receiver operating characteristics, and the area under these curves (AUC) +/- SE was used as the measure of diagnostic performance. AUC +/- SE for all patients were ML ECG, 0.66 +/- 0.03; EASI ECG, 0.64 +/- 0.03; and CP ECG, 0.67 +/- 0.03. Corresponding results for responders only were 0.81 +/- 0.04 for ML ECG, 0.78 +/- 0.04 for EASI ECG, and 0.81 +/- 0.04 for CP ECG. The differences between the AUCs for the different lead sets were not significant (P > .05). Thus, the EASI-derived 12-lead ECG is as good for detecting acute ischemia as is the 12-lead ECG acquired in CP.

[1]  O. Pahlm,et al.  The relative accuracies of ECG precordial lead waveforms derived from EASI leads and those acquired from paramedic applied standard leads. , 2003, Journal of electrocardiology.

[2]  B. Drew,et al.  Comparison of standard and derived 12-lead electrocardiograms for diagnosis of coronary angioplasty-induced myocardial ischemia. , 1997, The American journal of cardiology.

[3]  G. Dower The ECGD: a derivation of the ECG from VCG leads. , 1984, Journal of electrocardiology.

[4]  Galen S Wagner,et al.  Electrocardiographic ST-segment changes during acute myocardial ischemia. , 2002, Cardiac electrophysiology review.

[5]  Rungroj Krittayaphong,et al.  Derived 12-lead electrocardiogram in the assessment of ST-segment deviation and cardiac rhythm. , 2006, Journal of electrocardiology.

[6]  C L Feldman,et al.  Diagnostic accuracy of derived versus standard 12-lead electrocardiograms. , 2000, Journal of electrocardiology.

[7]  Dirk Q Feild,et al.  Statistical and deterministic approaches to designing transformations of electrocardiographic leads. , 2002, Journal of electrocardiology.

[8]  A J KERWIN,et al.  A method for the accurate placement of chest electrodes in the taking of serial electrocardiographic tracings. , 1960, Canadian Medical Association journal.

[9]  R. Tibshirani,et al.  An introduction to the bootstrap , 1993 .

[10]  E. Frank An Accurate, Clinically Practical System For Spatial Vectorcardiography , 1956, Circulation.

[11]  C. Feldman,et al.  Comparison of the standard ECG with the EASIcardiogram for ischemia detection during exercise monitoring , 1997, Computers in Cardiology 1997.

[12]  Dirk Q Feild,et al.  Improved EASI coefficients: their derivation, values, and performance. , 2002, Journal of electrocardiology.

[13]  L. Wolff,et al.  Positional and respiratory changes in precordial lead patterns simulating acute myocardial infarction. , 1958, American heart journal.

[14]  Simon H. Meij,et al.  Derived 12-Lead ECG Systems , 2006 .

[15]  F P Ottes,et al.  Statistical Comparison of ROC Curves from Multiple Readers , 1996, Medical decision making : an international journal of the Society for Medical Decision Making.

[16]  R. Califf,et al.  Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young , 2004, Circulation.

[17]  C. Feldman,et al.  Can the vectorcardiographically derived EASI ECG be a suitable surrogate for the standard ECG in selected circumstances , 1997, Computers in Cardiology 1997.

[18]  B. Drew,et al.  ST segment monitoring with a derived 12-lead electrocardiogram is superior to routine cardiac care unit monitoring. , 1996, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[19]  R. E. Mason,et al.  A new system of multiple-lead exercise electrocardiography. , 1966, American heart journal.

[20]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[21]  B. Drew,et al.  Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities. , 1999, Journal of electrocardiology.

[22]  C L Feldman,et al.  Optimal electrocardiographic leads for detecting acute myocardial ischemia. , 2001, Journal of electrocardiology.

[23]  J. Cook,et al.  Variability of electrocardiographic precordial lead placement: a method to improve accuracy and reliability. , 1991, Clinical cardiology.

[24]  Udo Sechtem,et al.  A vector-based, 5-electrode, 12-lead monitoring ECG (EASI) is equivalent to conventional 12-lead ECG for diagnosis of acute coronary syndromes. , 2006, Journal of electrocardiology.

[25]  E. W. Hancock,et al.  Comparability of 12-lead ECGs derived from EASI leads with standard 12-lead ECGS in the classification of acute myocardial ischemia and old myocardial infarction. , 2002, Journal of electrocardiology.

[26]  G E Dower,et al.  Deriving the 12-lead electrocardiogram from four (EASI) electrodes. , 1988, Journal of electrocardiology.

[27]  B. Drew,et al.  Comparison of a vectorcardiographically derived 12-lead electrocardiogram with the conventional electrocardiogram during wide QRS complex tachycardia, and its potential application for continuous bedside monitoring. , 1992, The American journal of cardiology.

[28]  Sophia Zhou,et al.  Comparison of EASI-derived 12-lead electrocardiograms versus paramedic-acquired 12-lead electrocardiograms using Mason-Likar limb lead configuration in patients with chest pain. , 2006, Journal of electrocardiology.