First results from the online variable line spacing grating spectrometer at FLASH

Abstract A high resolution online grating spectrometer has been set up at the free electron laser in Hamburg FLASH at DESY in Hamburg. This new photon diagnostic device allows to parasitically measure the spectral distribution of the FEL laser pulses on a single shot basis and therefore gives complementary spectral and temporal pulse information for user experiments and FEL operation. The spectrometer combines a plane mirror and two plane variable line spacing (VLS) gratings and is installed at the non-monochromized beamline branch at FLASH. In contrast to a standard grating the blaze angle is optimized for the zero-order radiation transferred to the experimental stations, leaving approximately 1–10% intensity for recording the wavelength in the spectrometer. The detector, an intensified CCD camera imaging the dispersed beam on a Ce:YAG crystal, can follow the focal plane of the gratings covering a wavelength ranging from 6 to 60 nm. The resolving power of the spectrometer is expected to range from 500 to 8000 depending on the FEL wavelength.

[1]  T. Harada,et al.  Mechanically ruled aberration-corrected concave gratings for a flat-field grazing-incidence spectrograph. , 1983, Applied optics.

[2]  L. A. Shmaenok,et al.  Measurement of gigawatt radiation pulses from a vacuum and extreme ultraviolet free-electron laser , 2003 .

[3]  Masao Seya,et al.  Geometric theory of the grating , 1974 .

[4]  D Sertore,et al.  Generation of GW radiation pulses from a VUV free-electron laser operating in the femtosecond regime. , 2002, Physical review letters.

[5]  Jana Buchheim,et al.  Characterization and calibration of 2nd generation slope measuring profiler , 2010 .

[6]  J. Bozek,et al.  Non-linear processes in the interaction of atoms and molecules with intense EUV and X-ray fields from SASE free electron lasers (FELs) , 2010 .

[7]  T. Harada,et al.  Mechanically ruled aberration-corrected concave gratings. , 1980, Applied optics.

[8]  H. Wabnitz,et al.  The soft x-ray free-electron laser FLASH at DESY: beamlines, diagnostics and end-stations , 2009 .

[9]  Ryszard S. Romaniuk,et al.  Operation of a free-electron laser from the extreme ultraviolet to the water window , 2007 .

[10]  T. Harada,et al.  Development of a flat-field grazing-incidence XUV spectrometer and its application in picosecond XUV spectroscopy. , 1984, Applied optics.

[11]  Jerome B. Hastings,et al.  Gas detectors for x-ray lasers , 2008 .

[12]  T. Zeschke,et al.  The Nanometer Optical Component Measuring Machine: a new Sub-nm Topography Measuring Device for X-ray Optics at BESSY , 2004 .

[13]  P. Nicolosi,et al.  First operation of a free-electron laser generating GW power radiation at 32 nm wavelength , 2006 .

[14]  Frank Siewert,et al.  Inspection of a Spherical Triple VLS‐Grating for Self‐Seeding of FLASH at DESY , 2007 .

[15]  Toshiaki Kita,et al.  Varied line‐spacing plane grating monochromator for undulator beamline , 1996 .