Suprathreshold Stereo-Depth Matches as a Function of Contrast and Spatial Frequency

Thresholds for stereoscopic-depth perception increase with decreasing spatial frequency below 2.5 cycles deg−1. Despite this variation of stereo threshold, suprathreshold stereoscopic-depth perception is independent of spatial frequency down to 0.5 cycle deg-1. Below this frequency the perceived depth of crossed disparities is less than that stimulated by higher spatial frequencies which subtend the same disparities. We have investigated the effects of contrast fading upon this breakdown of stereo-depth invariance at low spatial frequencies. Suprathreshold stereopsis was investigated with spatially filtered vertical bars (difference of Gaussian luminance distribution, or DOG functions) tuned narrowly over a broad range of spatial frequencies (0.15–9.6 cycles deg−1). Disparity subtended by variable width DOGs whose physical contrast ranged from 10–100% was adjusted to match the perceived depth of a standard suprathreshold disparity (5 min visual angle) subtended by a thin black line. Greater amounts of crossed disparity were required to match broad than narrow DOGs to the apparent depth of the standard black line. The matched disparity was greater at low than at high contrast levels. When perceived contrast of all the DOGs was matched to standard contrasts ranging from 5–72%, disparity for depth matches became similar for narrow and broad DOGs. 200 ms pulsed presentations of DOGs with equal perceived contrast further reduced the disparity of low-contrast broad DOGs needed to match the standard depth. A perceived-depth bias in the uncrossed direction at low spatial frequencies was noted in these experiments. This was most pronounced for low-contrast low-spatial-frequency targets, which actually needed crossed disparities to make a depth match to an uncrossed standard. This bias was investigated further by making depth matches to a zero-disparity standard (ie the apparent fronto-parallel plane). Broad DOGs, which are composed of low spatial frequencies, were perceived behind the fixation plane when they actually subtended zero disparity. The magnitude of this low-frequency depth bias increased as contrast was reduced. The distal depth bias was also perceived monocularly, however, it was always greater when viewed binocularly. This investigation indicates that contrast fading of low-spatial-frequency stimuli changes their perceived depth and enhances a depth bias in the uncrossed direction. The depth bias has both a monocular and a binocular component.