Positive-sequence grid voltage detector for distributed generation systems with no tuning requirements

This paper proposes a three-phase positive sequence detector that does not require any parameter to be adjusted. It operates in open loop and there is not any PI controller that needs to be tuned. The scheme includes the use of the Park transformation and moving average filters. Performance of the moving average filter is mathematically analyzed and represented in a Bode diagram. The analysis allows proper selection of the optimal filterpsilas window width for its application in d-q transformed variables. The proposed detector scheme allows fast detection of the grid voltage positive sequence. The MAF completely eliminates any oscillation multiple of the frequency for what it is designed. Thus, this algorithm is not affected by the presence of imbalances or harmonics in the electrical grid. The proposed positive-sequence detector is verified through simulation and experiment. It shows very good performance even under extreme grid voltage conditions.

[1]  S.M. Silva,et al.  Performance evaluation of PLL algorithms for single-phase grid-connected systems , 2004, Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting..

[2]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[3]  M. R. Iravani,et al.  A Nonlinear Adaptive Filter for Online Signal Analysis in Power Systems: Applications , 2002, IEEE Power Engineering Review.

[4]  Floyd M. Gardner,et al.  Phaselock techniques , 1984, IEEE Transactions on Systems, Man, and Cybernetics.

[5]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[6]  M.R. Iravani,et al.  A method for synchronization of power electronic converters in polluted and variable-frequency environments , 2004, IEEE Transactions on Power Systems.

[7]  F. Blaabjerg,et al.  Advanced Grid Synchronization System for Power Converters under Unbalanced and Distorted Operating Conditions , 2006, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[8]  Floyd M. Gardner,et al.  Phaselock Techniques: Gardner/Phaselock Techniques , 2005 .

[9]  J. Pou,et al.  Control of back-to-back-connected neutral-point-clamped converters in wind mill applications , 2007, 2007 European Conference on Power Electronics and Applications.

[10]  J. Bordonau,et al.  Fast on-line symmetrical components separation method for synchronization and control purposes in three phase distributed power generation systems. , 2007, 2007 European Conference on Power Electronics and Applications.