Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: a comparison between MCNP4C, GEANT3 and measurements.

Different codes are used for Monte Carlo (MC) calculations in radiation therapy. In this research, MCNP4C and GEANT3 codes have been compared in calculations of dosimetric characteristics of Varian Clinac 2300C/D. The parameters of influence in the differences seen in dosimetric features were discussed. This study emphasizes that both MCNP4C and GEANT3 MC can be used in radiation therapy computations and their differences in photon spectra calculations have a negligible effect on percentage depth dose computations in radiation therapy.

[1]  G. D. Valdez,et al.  ITS: the integrated TIGER series of electron/photon transport codes-Version 3.0 , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[2]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[3]  J J DeMarco,et al.  A CT-based Monte Carlo simulation tool for dosimetry planning and analysis. , 1998, Medical physics.

[4]  M. Fix,et al.  Monte Carlo simulation of a dynamic MLC based on a multiple source model. , 2001, Physics in medicine and biology.

[5]  S B Jiang,et al.  Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system. , 2000, Physics in medicine and biology.

[6]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[7]  Matthias Fippel,et al.  Smoothing Monte Carlo calculated dose distributions by iterative reduction of noise. , 2003, Physics in medicine and biology.

[8]  O. Chibani,et al.  Monte Carlo dose calculations in homogeneous media and at interfaces: a comparison between GEPTS, EGSnrc, MCNP, and measurements. , 2002, Medical physics.

[9]  Stephen M. Seltzer,et al.  Electron-photon Monte Carlo calculations: The ETRAN code , 1991 .

[10]  F. H. Attix,et al.  5 – Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry , 1990 .

[11]  R. Mohan,et al.  Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C. , 1999, Physics in medicine and biology.

[12]  C. Ma,et al.  Clinical implementation of a Monte Carlo treatment planning system. , 1999, Medical physics.

[13]  J. Battista,et al.  Improved lung dose calculation using tissue-maximum ratios in the Batho correction. , 1984, Medical physics.

[14]  Monte Carlo models for dosimetry in photon beam radiotherapy , 2002 .

[15]  S. Leisegang,et al.  Zum Energieverlust schneller Elektronen in dünnen Schichten , 1950 .

[16]  M. Fix,et al.  A multiple source model for 6 MV photon beam dose calculations using Monte Carlo. , 2001, Physics in medicine and biology.

[17]  P. Andreo Monte Carlo techniques in medical radiation physics. , 1991, Physics in medicine and biology.

[18]  Interface dosimetry: measurements and Monte Carlo simulations of low-energy photon beams , 2001 .

[19]  B. Faddegon,et al.  Description and dosimetric verification of the PEREGRINE Monte Carlo dose calculation system for photon beams incident on a water phantom. , 2001, Medical physics.

[20]  L Xing,et al.  Computer verification of fluence map for intensity modulated radiation therapy. , 2000, Medical physics.

[21]  P Rüegsegger,et al.  Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy. , 2000, Medical physics.

[22]  J. Cunningham,et al.  Evaluation of lung dose correction methods for photon irradiations of thorax phantoms. , 1989, International journal of radiation oncology, biology, physics.

[23]  F. H. Attix,et al.  The Dosimetry of Ionizing Radiation, Vol. 2 , 1987 .

[24]  D. Sheikh-Bagheri,et al.  Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters. , 2002, Medical physics.

[25]  B A Faddegon,et al.  Angular distribution of bremsstrahlung from 15-MeV electrons incident on thick targets of Be, Al, and Pb. , 1991, Medical physics.

[26]  R. Mohan,et al.  Dynamic-MLC Modeling for Monte Carlo dose calculations , 2000 .

[27]  R. Jeraj,et al.  Comparisons between MCNP, EGS4 and experiment for clinical electron beams. , 1999, Physics in medicine and biology.

[28]  J J DeMarco,et al.  A verification of the Monte Carlo code MCNP for thick target bremsstrahlung calculations. , 1995, Medical physics.

[29]  R. Mohan,et al.  Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set. , 2003, Medical Physics (Lancaster).

[30]  G. Ding,et al.  Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam. , 2002, Medical physics.

[31]  Jose Perez-Calatayud,et al.  Monte Carlo calculation of dose rate distributions around Ir192 wires , 1997 .

[32]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.

[33]  Kenneth R. Kase,et al.  The Dosimetry of Ionizing Radiation , 1986 .

[34]  R Mohan,et al.  Monte Carlo dose calculations for dynamic IMRT treatments. , 2001, Physics in medicine and biology.