A Pilot Protection for HVDC Transmission Lines Based on Transient Energy Ratio of DC Filter Link

To overcome shortages in the traditional current differential protection for HVDC transmission lines, a pilot protection based on transient energy ratio is proposed. The fault identification criterion is put forward based on the impedance-frequency characteristic of the line boundary, and the fault analysis which shows that under internal faults, with regard to either terminal of the dc line, the transient energy within a specific frequency band on the line side of the boundary is much greater than that on the valve side of the boundary, whereas after rectifier-terminal (inverter-terminal) external faults, the transient energy on the line side of the rectifier-terminal (inverter-terminal) boundary is much less than that on the valve side of the boundary. Moreover, the lightning disturbance identification criterion is implemented based on the magnitude ratio of fault components of high- and low-frequency band currents. Fault-pole selection is constructed by using the fault components of pole voltages. Simulation results demonstrate that the proposed scheme, with low computational complexity, can distinguish internal faults from external ones and protect the entire line reliably. It can also identify high-impedance faults and select the faulted pole correctly. Besides, it is not subject to lightning interferences and the dc line distributed capacitor.

[1]  Z. Q. Bo,et al.  Realization of the transient-based boundary protection for HVDC transmission lines based on high frequency energy criteria , 2010, 2010 International Conference on Power System Technology.

[2]  Gang Wang,et al.  Global-Sensitivity-Based Theoretical Analysis and Fast Prediction of Traveling Waves With Respect to Fault Resistance on HVDC Transmission Lines , 2015, IEEE Transactions on Power Delivery.

[3]  Zhiguo Hao,et al.  Development of a Novel Protection Device for Bipolar HVDC Transmission Lines , 2014, IEEE Transactions on Power Delivery.

[4]  Wang Jia,et al.  Double-Exponential Expression of Lightning Current Waveforms , 2006, The 2006 4th Asia-Pacific Conference on Environmental Electromagnetics.

[5]  Alan R. Wood,et al.  The frequency dependent impedance of an HVDC converter , 1995 .

[6]  Bao-Hui Zhang,et al.  Study of Non-Unit Transient-Based Protection for HVDC Transmission Lines , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[7]  K.S. Swarup,et al.  Computationally Efficient Wavelet-Transform-Based Digital Directional Protection for Busbars , 2007, IEEE Transactions on Power Delivery.

[8]  Xiaolei Liu,et al.  Real-Time Implementation of a Hybrid Protection Scheme for Bipolar HVDC Line Using FPGA , 2011, IEEE Transactions on Power Delivery.

[9]  Tai Nengling,et al.  Travelling wave‐based pilot direction comparison protection for HVDC line , 2013 .

[10]  Jian Liu,et al.  A novel pilot directional protection scheme for HVDC transmission line based on specific frequency current , 2014, 2014 International Conference on Power System Technology.

[11]  Jingzhe Tu,et al.  Transient reactive power characteristics of HVDC during commutation failure and impact of HVDC control parameters , 2009 .

[12]  Jilai Yu,et al.  Study on Electrical Transient Protection for ±800kV UHVDC Transmission Lines , 2012, 2012 Asia-Pacific Power and Energy Engineering Conference.

[13]  S. P. Valsan,et al.  Protective relaying for power transformers using field programmable gate array , 2008 .

[14]  Guobing Song,et al.  Novel pilot protection principle for high-voltage direct current transmission lines based on fault component current characteristics , 2015 .

[15]  O.P. Malik,et al.  Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line , 2009, IEEE Transactions on Power Delivery.

[16]  Zaibin Jiao,et al.  A New Whole-Line Quick-Action Protection Principle for HVDC Transmission Lines Using One-End Current , 2015, IEEE Transactions on Power Delivery.

[17]  Zhiguo Hao,et al.  Improved differential current protection scheme for CSC-HVDC transmission lines , 2017 .

[18]  Xin Wang,et al.  Identification of Lightning Stroke and Fault in the Transient Component Based Protection , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[19]  Xianzhong Duan,et al.  Efficient approach to quantify commutation failure immunity levels in multi-infeed HVDC systems , 2016 .

[20]  Christian Rehtanz,et al.  Identification of Lightning Stroke Due to Shielding Failure and Backflashover for Ultra-High-Speed Transmission-Line Protection , 2014, IEEE Transactions on Power Delivery.

[21]  T. Hisakado,et al.  An application of wavelet transform to fault location and its implementation on FPGA , 2001, Proceedings of the 44th IEEE 2001 Midwest Symposium on Circuits and Systems. MWSCAS 2001 (Cat. No.01CH37257).

[22]  Yaozhong Ge,et al.  Surge impedance relay , 2005, IEEE Transactions on Power Delivery.

[23]  Liang Wang,et al.  Transient simulation of lightning strokes on HVDC transmission lines and fault pole selection , 2017, 2017 2nd International Conference on Power and Renewable Energy (ICPRE).

[24]  Zaibin Jiao,et al.  Distance Protection for HVDC Transmission Lines Considering Frequency-Dependent Parameters , 2013, IEEE Transactions on Power Delivery.

[25]  Xianzhong Duan,et al.  Single-end time-domain transient electrical signals based protection principle and its efficient setting calculation method for LCC-HVDC lines , 2017 .