An accurate nonuniform fourier transform for SPRITE magnetic resonance imaging data

A new algorithm is proposed for computing the discrete Fourier Transform (DFT) of purely phase encoded data acquired during Magnetic Resonance Imaging (MRI) experiments. These experiments use the SPRITE (Single Point Ramped Imaging with T1 Enhancement) method and multiple-point acquisition, sampling data in a nonuniform manner that prohibits reconstruction by fast Fourier transform. The chirp z-transform algorithm of Rabiner, Schafer, and Rader can be combined with phase corrections to compute the DFT of this data to extremely high accuracy. This algorithm outperforms the interpolation methods that are traditionally used to process nonuniform data, both in terms of execution time and in terms of accuracy as compared to the DFT.

[1]  J. Tukey,et al.  An algorithm for the machine calculation of complex Fourier series , 1965 .

[2]  L. Rabiner,et al.  The chirp z-transform algorithm , 1969 .

[3]  L. Bluestein A linear filtering approach to the computation of discrete Fourier transform , 1970 .

[4]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[5]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[6]  B. Balcom,et al.  Single-Point Ramped Imaging with T1 Enhancement (SPRITE) , 1996, Journal of magnetic resonance. Series A.

[7]  Q. Liu,et al.  An accurate algorithm for nonuniform fast Fourier transforms (NUFFT's) , 1998 .

[8]  Prado,et al.  Magnetic Resonance Imaging of Gases: A Single-Point Ramped Imaging with T1 Enhancement (SPRITE) Study. , 1999, Journal of magnetic resonance.

[9]  Qing Huo Liu,et al.  The Regular Fourier Matrices and Nonuniform Fast Fourier Transforms , 1999, SIAM J. Sci. Comput..

[10]  B. Balcom,et al.  Magnetic Resonance Imaging of Gases: A Single-Point Ramped Imaging withT1Enhancement (SPRITE) Study☆ , 1999 .

[11]  R. Cox,et al.  Direct reconstruction of non‐Cartesian k‐space data using a nonuniform fast Fourier transform , 2001, Magnetic resonance in medicine.

[12]  Bruce J Balcom,et al.  Centric scan SPRITE magnetic resonance imaging. , 2003, Journal of magnetic resonance.

[13]  A. Song,et al.  An improved gridding method for spiral MRI using nonuniform fast Fourier transform. , 2003, Journal of magnetic resonance.

[14]  James Rioux,et al.  Non-Uniform Fast Fourier Transformation of SPRITE MRI Data , 2003 .

[15]  H. D. Morris,et al.  K‐space in the clinic , 2004, Journal of magnetic resonance imaging : JMRI.

[16]  N J Shah,et al.  Centric scan SPRITE magnetic resonance imaging: optimization of SNR, resolution, and relaxation time mapping. , 2004, Journal of magnetic resonance.

[17]  B. Balcom,et al.  Application of the chirp z-transform to MRI data. , 2006, Journal of magnetic resonance.

[18]  A.,et al.  FAST FOURIER TRANSFORMS FOR NONEQUISPACED DATA * , 2022 .