Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain.

We present the design process of a superconducting volume coil for magnetic resonance microscopy of the mouse brain at 9.4T. The yttrium barium copper oxide coil has been designed through an iterative process of three-dimensional finite-element simulations and validation against room temperature copper coils. Compared to previous designs, the Helmholtz pair provides substantially higher B(1) homogeneity over an extended volume of interest sufficiently large to image biologically relevant specimens. A custom-built cryogenic cooling system maintains the superconducting probe at 60+/-0.1K. Specimen loading and probe retuning can be carried out interactively with the coil at operating temperature, enabling much higher through-put. The operation of the probe is a routine, consistent procedure. Signal-to-noise ratio in a mouse brain increased by a factor ranging from 1.1 to 2.9 as compared to a room-temperature solenoid coil optimized for mouse brain microscopy. We demonstrate images encoded at 10x10x20mum for an entire mouse brain specimen with signal-to-noise ratio of 18 and a total acquisition time of 16.5h, revealing neuroanatomy unseen at lower resolution. Phantom measurements show an effective spatial resolution better than 20mum.

[1]  Jyh-Horng Chen,et al.  High-T/sub c/ Superconducting receiving coils for nuclear magnetic resonance imaging , 2005 .

[2]  G. Allan Johnson,et al.  High-throughput morphologic phenotyping of the mouse brain with magnetic resonance histology , 2007, NeuroImage.

[3]  Stéphane Serfaty,et al.  Multi‐turn split‐conductor transmission‐line resonators , 1997, Magnetic resonance in medicine.

[4]  G A Johnson,et al.  A high‐temperature superconducting Helmholtz probe for microscopy at 9.4 T , 1999, Magnetic resonance in medicine.

[5]  L. Hedlund,et al.  Morphologic phenotyping with MR microscopy: the visible mouse. , 2002, Radiology.

[6]  Luc Darrasse,et al.  Quick measurement of NMR‐coil sensitivity with a dual‐loop probe , 1993 .

[7]  L. Ciobanu,et al.  3D MR microscopy with resolution 3.7μm by 3.3μm by 3.3μm , 2002 .

[8]  J R MacFall,et al.  Performance of a high‐temperature superconducting probe for in vivo microscopy at 2.0 T , 1999, Magnetic resonance in medicine.

[9]  A. Haase,et al.  A superconducting probehead applicable for nuclear magnetic resonance microscopy at 7 T , 1998 .

[10]  G. Johnson,et al.  Performance of a high-temperature superconducting resonator for high-field imaging , 1995 .

[11]  G Allan Johnson,et al.  Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents , 2005, Magnetic resonance in medicine.

[12]  L. Hedlund,et al.  Magnetic resonance histology for morphologic phenotyping , 2002, Journal of magnetic resonance imaging : JMRI.

[13]  Chang-Beom Ahn,et al.  Nuclear magnetic resonance microscopy with 4-μm resolution: Theoretical study and experimental results , 1988 .

[14]  L Darrasse,et al.  Perspectives with cryogenic RF probes in biomedical MRI. , 2003, Biochimie.

[15]  Z. H. Cho,et al.  Recent progress in NMR microscopy towards cellular imaging , 1990, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences.

[16]  G.-C. Liang,et al.  Thin-film HTS probe coils for magnetic-resonance imaging , 1993, IEEE Transactions on Applied Superconductivity.

[17]  Tomoyuki Haishi,et al.  A solution to the dynamic range problem in MRI using a parallel image acquisition , 2006 .

[18]  P. Callaghan,et al.  Diffusion-limited resolution in nuclear magnetic resonance microscopy , 1988 .

[19]  R E Jacobs,et al.  Magnetic resonance microscopy of embryonic cell lineages and movements. , 1994, Science.

[20]  C. Cheong,et al.  One micrometer resolution NMR microscopy. , 2001, Journal of magnetic resonance.

[21]  A. S. Hall,et al.  Use of high temperature superconductor in a receiver coil for magnetic resonance imaging , 1991, Magnetic resonance in medicine.

[22]  S. Kan,et al.  Double‐bracelet resonator Helmholtz probe for NMR experiments , 1995 .

[23]  A Mogro-Campero,et al.  A high-temperature superconducting receiver for nuclear magnetic resonance microscopy. , 1993, Science.

[24]  A refined circuit model of high temperature superconducting spiral coils for MRI , 2001 .

[25]  Kelvin K. Wong,et al.  Design of superconducting MRI surface coil by using method of moment , 2002 .