X-ray diffraction at the National Ignition Facility.

We report details of an experimental platform implemented at the National Ignition Facility to obtain in situ powder diffraction data from solids dynamically compressed to extreme pressures. Thin samples are sandwiched between tamper layers and ramp compressed using a gradual increase in the drive-laser irradiance. Pressure history in the sample is determined using high-precision velocimetry measurements. Up to two independently timed pulses of x rays are produced at or near the time of peak pressure by laser illumination of thin metal foils. The quasi-monochromatic x-ray pulses have a mean wavelength selectable between 0.6 Å and 1.9 Å depending on the foil material. The diffracted signal is recorded on image plates with a typical 2θ x-ray scattering angle uncertainty of about 0.2° and resolution of about 1°. Analytic expressions are reported for systematic corrections to 2θ due to finite pinhole size and sample offset. A new variant of a nonlinear background subtraction algorithm is described, which has been used to observe diffraction lines at signal-to-background ratios as low as a few percent. Variations in system response over the detector area are compensated in order to obtain accurate line intensities; this system response calculation includes a new analytic approximation for image-plate sensitivity as a function of photon energy and incident angle. This experimental platform has been used up to 2 TPa (20 Mbar) to determine the crystal structure, measure the density, and evaluate the strain-induced texturing of a variety of compressed samples spanning periods 2-7 on the periodic table.

[1]  J. R. Rygg,et al.  Optimized x-ray sources for x-ray diffraction measurements at the Omega Laser Facility. , 2019, The Review of scientific instruments.

[2]  J. Eggert,et al.  Refractive index of lithium fluoride to 900 gigapascal and implications for dynamic equation of state measurements , 2019, Journal of Applied Physics.

[3]  Marius Millot,et al.  Nanosecond X-ray diffraction of shock-compressed superionic water ice , 2019, Nature.

[4]  S. Regan,et al.  X-ray spectrometer throughput model for (selected) flat Bragg crystal spectrometers on laser plasma facilities. , 2018, The Review of scientific instruments.

[5]  Raymond Jeanloz,et al.  Insulator-metal transition in dense fluid deuterium , 2018, Science.

[6]  Christopher T. Seagle,et al.  X-ray diffraction of ramp-compressed aluminum to 475 GPa , 2018, Physics of Plasmas.

[7]  Jon H. Eggert,et al.  Equation of state of iron under core conditions of large rocky exoplanets , 2018 .

[8]  J. R. Rygg,et al.  Crystal structure and equation of state of Fe-Si alloys at super-Earth core conditions , 2018, Science Advances.

[9]  Gilbert W. Collins,et al.  Experimental evidence for superionic water ice using shock compression , 2018 .

[10]  Gilbert W. Collins,et al.  Measurement of Body-Centered-Cubic Aluminum at 475 GPa. , 2017, Physical review letters.

[11]  Jon H. Eggert,et al.  An iterative forward analysis technique to determine the equation of state of dynamically compressed materials , 2017 .

[12]  M. Knudson,et al.  Mechanical response of lithium fluoride under off-principal dynamic shock-ramp loading , 2016 .

[13]  M. Knudson,et al.  Mechanical and optical response of [100] lithium fluoride to multi-megabar dynamic pressures , 2016 .

[14]  I. Silvera,et al.  Observation of the Wigner-Huntington transition to metallic hydrogen , 2016, Science.

[15]  Gilbert W. Collins,et al.  X-ray diffraction of molybdenum under ramp compression to 1 TPa , 2016 .

[16]  R. Si,et al.  Energy levels and transition rates for helium-like ions with Z = 10–36 , 2016 .

[17]  D. Kalantar,et al.  TARDIS-C: A target diagnostic for measuring material structure at high pressure , 2016 .

[18]  J. Moody,et al.  Electron temperature measurements inside the ablating plasma of gas-filled hohlraums at the National Ignition Facility , 2016 .

[19]  Gilbert W. Collins,et al.  X-ray diffraction of molybdenum under shock compression to 450 GPa , 2015 .

[20]  Gilbert W. Collins,et al.  The effect of nearly steady shock waves in ramp compression experiments , 2015 .

[21]  David J Erskine,et al.  Ghost fringe removal techniques using Lissajous data presentation. , 2015, The Review of scientific instruments.

[22]  Gilbert W. Collins,et al.  X-Ray Diffraction of Solid Tin to 1.2 TPa. , 2015, Physical review letters.

[23]  Gilbert W. Collins,et al.  X-ray area backlighter development at the National Ignition Facility (invited). , 2014, The Review of scientific instruments.

[24]  C Stoeckl,et al.  Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited). , 2014, The Review of scientific instruments.

[25]  R. F. Smith,et al.  Ramp compression of diamond to five terapascals , 2014, Nature.

[26]  Hui Chen,et al.  Calibration and equivalency analysis of image plate scanners. , 2014, The Review of scientific instruments.

[27]  Roald Hoffmann,et al.  High pressure electrides: a predictive chemical and physical theory. , 2014, Accounts of chemical research.

[28]  R. J. Scharff,et al.  Determining the refractive index of shocked [100] lithium fluoride to the limit of transmissibility , 2014 .

[29]  Jon H. Eggert,et al.  Experimental evidence for a phase transition in magnesium oxide at exoplanet pressures , 2013 .

[30]  M. Tarisien,et al.  Response functions of imaging plates to photons, electrons and 4He particles. , 2013, The Review of scientific instruments.

[31]  G. F. Stone,et al.  X-ray and neutron sensitivity of imaging plates , 2013, Optics & Photonics - Optical Engineering + Applications.

[32]  J. Ayers,et al.  X-ray diffraction diagnostic design for the National Ignition Facility , 2013, Optics & Photonics - Optical Engineering + Applications.

[33]  J. Eggert,et al.  A novel approach to Hugoniot measurements utilizing transparent crystals , 2013 .

[34]  Gilbert W. Collins,et al.  Powder diffraction from solids in the terapascal regime. , 2012, The Review of scientific instruments.

[35]  Y. P. Opachich,et al.  Measuring x-ray burn history with the Streaked Polar Instrumentation for Diagnosing Energetic Radiation (SPIDER) at the National Ignition Facility (NIF) , 2012, Other Conferences.

[36]  Gilbert W. Collins,et al.  The direct measurement of ablation pressure driven by 351-nm laser radiation , 2011 .

[37]  Gilbert W. Collins,et al.  Refractive index of lithium fluoride ramp compressed to 800 GPa , 2011 .

[38]  S. Sinogeikin,et al.  Cold melting and solid structures of dense lithium , 2011 .

[39]  Chris J Pickard,et al.  Aluminium at terapascal pressures. , 2010, Nature materials.

[40]  B. Remington,et al.  High-energy x-ray backlighter spectrum measurements using calibrated image plates. , 2010, The Review of scientific instruments.

[41]  T. C. Sangster,et al.  Initial Results from the OMEGA EP Laser System , 2009 .

[42]  Christopher T. Chantler,et al.  Hydrogenic Lamb shift in Ge31+ and the fine-structure Lamb shift , 2009 .

[43]  Edward I. Moses,et al.  The National Ignition Facility: Ushering in a new age for high energy density science , 2009 .

[44]  Yanming Ma,et al.  Transparent dense sodium , 2009, Nature.

[45]  Gilbert W. Collins,et al.  Diamond at 800 GPa. , 2009, Physical review letters.

[46]  C. Bentley,et al.  Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics. , 2008, The Review of scientific instruments.

[47]  M. Morhác,et al.  Peak Clipping Algorithms for Background Estimation in Spectroscopic Data , 2008, Applied spectroscopy.

[48]  E. Prince International Tables for Crystallography: Mathematical, physical and chemical tables , 2006 .

[49]  S. D. Rothman,et al.  Characteristics analysis of Isentropic Compression Experiments (ICE) , 2006 .

[50]  Lynn G. Seppala,et al.  Overview of the line-imaging VISAR diagnostic at the National Ignition Facility (NIF) , 2006, International Optical Design Conference.

[51]  Jon H. Eggert,et al.  Systematic uncertainties in shock-wave impedance-match analysis and the high-pressure equation of state of Al , 2005 .

[52]  H. Mao,et al.  Melting of dense sodium. , 2005, Physical review letters.

[53]  David K. Bradley,et al.  Line-imaging velocimeter for shock diagnostics at the OMEGA laser facility , 2004 .

[54]  J. R. Maw,et al.  A Characteristics Code for Analysis of Isentropic Compression Experiments , 2004 .

[55]  Jerome M. Auerbach,et al.  NIF final optics system: frequency conversion and beam conditioning , 2004, SPIE LASE.

[56]  J. B. Neaton,et al.  Pairing in dense lithium , 1999, Nature.

[57]  W. Nellis,et al.  Minimum metallic conductivity of fluid hydrogen at 140 GPa (1.4 Mbar) , 1999 .

[58]  Lalit C. Chhabildas,et al.  Time-resolved particle velocity measurements at impact velocities of 10 km/s , 1998 .

[59]  M. Morhác,et al.  Background elimination methods for multidimensional coincidence γ-ray spectra , 1997 .

[60]  Hill,et al.  Experimental study of the x-ray transitions in the heliumlike isoelectronic sequence. , 1989, Physical review. A, General physics.

[61]  D. R. Cousens,et al.  SNIP, A STATISTICS-SENSITIVE BACKGROUND TREATMENT FOR THE QUANTITATIVE-ANALYSIS OF PIXE SPECTRA IN GEOSCIENCE APPLICATIONS , 1988 .

[62]  E. Thorsos,et al.  Explosive-pusher-type laser compression experiments with neon-filled microballoons , 1979 .

[63]  H. Klug A.Redetermination of the Lattice Constant of Lead , 1946 .

[64]  I. Silvera,et al.  Observation of the Wigner-Huntington Transition to Solid Metallic Hydrogen , 2016 .

[65]  M. Desjarlais,et al.  Supplementary Materials for Direct observation of an abrupt insulator-to-metal transition in dense liquid deuterium , 2015 .

[66]  Samuel A. Letzring,et al.  Initial performance results of the OMEGA laser system , 1997 .

[67]  M. Rosenbluth Parametric Instabilities in Inhomogeneous Media , 1972 .