Reactive deposition of nano-films in deep polymeric microcavities.

We report the controlled diffusion of gas-phase high-reactivity chemical species into long polymeric microcavities to form glass-like, low-permeability barrier films on the interior surfaces of the microcavities. Reactive species created from fragmentation of O(2) and hexamethyldisiloxane (HMDSO) in a radio-frequency (RF) plasma environment are allowed to diffuse into the microcavities of polydimethylsiloxane (PDMS), where surface reactions lead to the formation of an effective, glass-like thin-film barrier. Reactive species including silicon radicals and elemental oxygen maintain their reactivity for sufficient times (up to 7000 s) and survive the random diffusional walk through the microcavities to form glass barriers as much as 65 mm from the cavity entrance. The barrier thickness and the growth length can be controlled by the reaction time and chamber operating pressure. Increasing the cross sectional area of the cavity inlet and/or decreasing the mean free path was found to increase the thickness of the barrier film. Optical emission spectroscopic analysis was used to characterize the reactive fragments formed from HMDSO, and energy-dispersive X-ray analysis revealed that the barrier composition is consistent with oxides of silicon (SiO(x)). Formed inside PDMS microcavities, the glass barrier blocks the penetration or absorption of small molecules such as rhodamine B (RhB) and biotin, and also resists permeation of organic solvents such as toluene, preventing the PDMS microfluidic structures from swelling and deforming. Moreover, formation of glass-like thin films in PDMS microcavities enhances the stability of electroosmotic flow (EOF) relative to uncoated PDMS devices, in which EOF instabilities are significant; this enables separation by electrophoresis with reproducibility (relative standard deviation 3%, n = 5) and baseline peak resolution (R:1.3) comparable to that obtained in conventional fused-silica capillaries.

[1]  Luke P. Lee,et al.  Optofluidic control using photothermal nanoparticles , 2006, Nature materials.

[2]  Hongyuan Chen,et al.  Low EOF rate measurement based on constant effective mobility in microchip CE , 2007, Electrophoresis.

[3]  Yong Kim,et al.  Plasma enhanced chemical vapor deposition of silicon oxide films using TMOS/O2 gas and plasma diagnostics , 2003 .

[4]  A. Riaz,et al.  Transient isotachophoresis of highly saline trace metals under strong electroosmotic flow conditions , 2005, Electrophoresis.

[5]  G. Turban,et al.  A comparative study of oxygen/organosilicon plasmas and thin SiOxCyHz films deposited in a helicon reactor , 2000 .

[6]  Luke P. Lee,et al.  Microfluidic self-assembly of tumor spheroids for anticancer drug discovery , 2008, Biomedical microdevices.

[7]  C. Culbertson,et al.  Surface engineering of poly(dimethylsiloxane) microfluidic devices using transition metal sol-gel chemistry. , 2006, Langmuir : the ACS journal of surfaces and colloids.

[8]  C. Cotman,et al.  A microfluidic culture platform for CNS axonal injury, regeneration and transport , 2005, Nature Methods.

[9]  G. Whitesides,et al.  Fabrication of microfluidic systems in poly(dimethylsiloxane) , 2000, Electrophoresis.

[10]  C. Henry,et al.  Plasma Modification of PDMS Microfluidic Devices for Control of Electroosmotic Flow , 2007 .

[11]  L. Blum,et al.  Direct Poly(dimethylsiloxane) Surface Functionalization with Vinyl Modified DNA , 2008 .

[12]  J. Lahann,et al.  Surface modification of confined microgeometries via vapor-deposited polymer coatings. , 2006, Journal of the American Chemical Society.

[13]  Yu-Hwa Lo,et al.  UV/ozone modification of poly(dimethylsiloxane) microfluidic channels , 2004 .

[14]  D. Chung,et al.  Calibration of migration times of variable salinity samples with internal standards in capillary electrophoresis , 2006, Electrophoresis.

[15]  S. Quake,et al.  Versatile, fully automated, microfluidic cell culture system. , 2007, Analytical chemistry.

[16]  G. Whitesides The origins and the future of microfluidics , 2006, Nature.

[17]  D. Chung,et al.  Capillary electrophoresis of trace metals in highly saline physiological sample matrices , 2003, Electrophoresis.

[18]  Jianding Qiu,et al.  Deoxyribonucleic acid modified poly(dimethylsiloxane) microfluidic channels for the enhancement of microchip electrophoresis. , 2009, Talanta.

[19]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[20]  Mark Bachman,et al.  Tailoring the surface properties of poly(dimethylsiloxane) microfluidic devices. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[21]  S. Quake,et al.  From micro- to nanofabrication with soft materials. , 2000, Science.

[22]  D. Theirich,et al.  Intermediate gas phase precursors during plasma CVD of HMDSO , 2003 .

[23]  Masahiro Yamazaki,et al.  Industrialization and application development of cyclo-olefin polymer , 2004 .

[24]  Sang‐Hee Shim,et al.  Dual stacking of unbuffered saline samples, transient isotachophoresis plus induced pH junction focusing , 2003, Electrophoresis.

[25]  Luke P. Lee,et al.  Hybrid integrated PDMS microfluidics with a silica capillary. , 2010, Lab on a chip.

[26]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[27]  A. Abate,et al.  Glass coating for PDMS microfluidic channels by sol-gel methods. , 2008, Lab on a chip.

[28]  C. Culbertson,et al.  Sol-gel modified poly(dimethylsiloxane) microfluidic devices with high electroosmotic mobilities and hydrophilic channel wall characteristics. , 2005, Analytical chemistry.

[29]  A. Manz,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[30]  J. Berg,et al.  Studies on surface wettability of poly(dimethyl) siloxane (PDMS) and glass under oxygen-plasma treatment and correlation with bond strength , 2005, Journal of Microelectromechanical Systems.

[31]  K. Jensen,et al.  Cells on chips , 2006, Nature.

[32]  C. Henry,et al.  Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips. , 2000, Analytical chemistry.

[33]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[34]  J. Lahann Vapor-based polymer coatings for potential biomedical applications , 2006 .

[35]  Jin Ho Kim,et al.  Surface modification of poly(dimethylsiloxane) microchannels , 2003, Electrophoresis.

[36]  M. Gijs,et al.  Internal modification of poly(dimethylsiloxane) microchannels with a borosilicate glass coating. , 2008, Langmuir : the ACS journal of surfaces and colloids.