Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT

We investigate the effect of heart rate on the quality and artifact generation in coronary artery images obtained using multi-slice computed tomography (MSCT) with the purpose of finding the optimal time resolution for data acquisition. To perform the study, we used the 4D NCAT phantom, a computer model of the normal human anatomy and cardiac and respiratory motions developed in our laboratory. Although capable of being far more realistic, the 4D NCAT cardiac model was originally designed for low-resolution imaging research, and lacked the anatomical detail to be applicable to high-resolution CT. In this work, we updated the cardiac model to include a more detailed anatomy and physiology based on high-resolution clinical gated MSCT data. To demonstrate its utility in high-resolution dynamic CT imaging research, the enhanced 4D NCAT was then used in a pilot simulation study to investigate the effect of heart rate on CT angiography. The 4D NCAT was used to simulate patients with different heart rates (60-120 beats/minute) and with various cardiac plaques of known size and location within the coronary arteries. For each simulated patient, MSCT projection data was generated with data acquisition windows ranging from 100 to 250 ms centered within the quiet phase (mid-diastole) of the heart using an analytical CT projection algorithm. CT images were reconstructed from the projection data, and the contrast of the plaques was then measured to assess the effect of heart rate and to determine the optimal time resolution required for each case. The 4D NCAT phantom with its realistic model for the cardiac motion was found to provide a valuable tool from which to optimize CT cardiac applications. Our results indicate the importance of optimizing the time resolution with regard to heart rate and plaque location for improved CT images at a reduced patient dose.

[1]  Thomas J Vogl,et al.  Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. , 2006, Radiology.

[2]  A. Young,et al.  Three-dimensional motion and deformation of the heart wall: estimation with spatial modulation of magnetization--a model-based approach. , 1992, Radiology.

[3]  Eric C. Frey,et al.  Validation of the 4D NCAT simulation tools for use in high-resolution x-ray CT research , 2005, SPIE Medical Imaging.

[4]  Alistair A. Young,et al.  Tracking and finite element analysis of stripe deformation in magnetic resonance tagging , 1995, IEEE Trans. Medical Imaging.

[5]  D. Lalush,et al.  A realistic spline-based dynamic heart phantom , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[6]  William P. Segars,et al.  A realistic spline-based dynamic heart phantom , 1998 .

[7]  Jinah Park,et al.  Analysis of left ventricular wall motion based on volumetric deformable models and MRI-SPAMM , 1996, Medical Image Anal..

[8]  Jinah Park,et al.  Deformable models with parameter functions for cardiac motion analysis from tagged MRI data , 1996, IEEE Trans. Medical Imaging.

[9]  Benjamin M. W. Tsui,et al.  Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms , 1999 .

[10]  U Joseph Schoepf,et al.  CT of coronary artery disease. , 2004, Journal of thoracic imaging.

[11]  Philip Costello,et al.  CT of coronary artery disease. , 2004, Radiology.

[12]  Leon Axel,et al.  Quantification and visualization of the 3D nonrigid motion of the left ventricle , 1997, Medical Imaging.

[13]  William Paul Segars,et al.  Development of a new dynamic NURBS-based cardiac-torso (NCAT) phantom , 2001 .

[14]  Willi A. Kalender,et al.  Computed tomography : fundamentals, system technology, image quality, applications , 2000 .