Image reconstruction from phased-array MRI data based on multichannel blind deconvolution

In this paper we consider image reconstruction from multichannel phased array MRI data without prior knowledge of the coil sensitivity functions. A new framework based on multichannel blind deconvolution (MBD) is developed for joint estimation of the image function and the sensitivity functions in k-space. By exploiting the smoothness of the estimated functions in the spatial domain, we develop a regularization approach in conjunction with MBD to obtain good reconstruction of the image function. Experimental results using simulated and real data demonstrate that the proposed reconstruction algorithm can better removes the sensitivity weighting in the reconstructed images compared to the sum-of-squares (SoS) approach.

[1]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[2]  J W Murakami,et al.  Intensity correction of phased‐array surface coil images , 1996, Magnetic resonance in medicine.

[3]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[4]  T. Chan,et al.  Convergence of the alternating minimization algorithm for blind deconvolution , 2000 .

[5]  Dwight G Nishimura,et al.  Multiple‐profile homogeneous image combination: Application to phase‐cycled SSFP and multicoil imaging , 2008, Magnetic resonance in medicine.

[6]  Jan Flusser,et al.  A Unified Approach to Superresolution and Multichannel Blind Deconvolution , 2007, IEEE Transactions on Image Processing.

[7]  F. Ulaby Fundamentals of applied electromagnetics , 1998 .

[8]  Norbert Schuff,et al.  Restoration of MRI data for intensity non-uniformities using local high order intensity statistics , 2009, Medical Image Anal..

[9]  Mathews Jacob,et al.  MULTICHANNEL ESTIMATION OF COIL SENSITIVITIES IN PARALLEL MRI , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[10]  Bo Liu,et al.  A statistical approach to SENSE regularization with arbitrary k‐space trajectories , 2008, Magnetic resonance in medicine.

[11]  L. Axel,et al.  Intensity correction in surface-coil MR imaging. , 1987, AJR. American journal of roentgenology.

[12]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[13]  Chrysostomos L. Nikias,et al.  EVAM: an eigenvector-based algorithm for multichannel blind deconvolution of input colored signals , 1995, IEEE Trans. Signal Process..

[14]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[15]  Fawwaz T. Ulaby Fundamentals of Applied Electromagnetics, 1999 Edition , 1998 .

[16]  James W Goldfarb The SENSE ghost: Field‐of‐view restrictions for SENSE imaging , 2004, Journal of magnetic resonance imaging : JMRI.

[17]  Gjlles Aubert,et al.  Mathematical problems in image processing , 2001 .

[18]  Yoram Bresler,et al.  Perfect blind restoration of images blurred by multiple filters: theory and efficient algorithms , 1999, IEEE Trans. Image Process..

[19]  S.J. Riederer,et al.  Phase alignment of multiple surface coil data for reduced bandwidth and reconstruction requirements in volumetric MRI applications , 1997, IEEE Antennas and Propagation Society International Symposium 1997. Digest.

[20]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[21]  Yingbo Hua,et al.  Previously Published Works Uc Riverside Title: Fast Maximum Likelihood for Blind Identification of Multiple Fir Channels Fast Maximum Likelihood for Blind Identification of Multiple Fir Channels , 2022 .

[22]  Leslie Ying,et al.  Joint image reconstruction and sensitivity estimation in SENSE (JSENSE) , 2007, Magnetic resonance in medicine.

[23]  B. A. D. H. Brandwood A complex gradient operator and its applica-tion in adaptive array theory , 1983 .