Concurrent and predictive validation of a novel robotic surgery simulator: a prospective, randomized study.

PURPOSE We evaluated the concurrent and predictive validity of a novel robotic surgery simulator in a prospective, randomized study. MATERIALS AND METHODS A total of 24 robotic surgery trainees performed virtual reality exercises on the da Vinci® Skills Simulator using the da Vinci Si™ surgeon console. Baseline simulator performance was captured. Baseline live robotic performance on ex vivo animal tissue exercises was evaluated by 3 expert robotic surgeons using validated laparoscopic assessment metrics. Trainees were then randomized to group 1-simulator training and group 2-no training while matched for baseline tissue scores. Group 1 trainees underwent a 10-week simulator curriculum. Repeat tissue exercises were done at study conclusion to assess performance improvement. Spearman's analysis was used to correlate baseline simulator performance with baseline ex vivo tissue performance (concurrent validity) and final tissue performance (predictive validity). The Kruskal-Wallis test was used to compare group performance. RESULTS Groups 1 and 2 were comparable in pre-study surgical experience and had similar baseline scores on simulator and tissue exercises (p >0.05). Overall baseline simulator performance significantly correlated with baseline and final tissue performance (concurrent and predictive validity each r = 0.7, p <0.0001). Simulator training significantly improved tissue performance on key metrics for group 1 subjects with lower baseline tissue scores (below the 50th percentile) than their group 2 counterparts (p <0.05). Group 1 tended to outperform group 2 on final tissue performance, although the difference was not significant (p >0.05). CONCLUSIONS Our study documents the concurrent and predictive validity of the Skills Simulator. The benefit of simulator training appears to be most substantial for trainees with low baseline robotic skills.

[1]  Thenkurussi Kesavadas,et al.  Content validation of a novel robotic surgical simulator , 2011, BJU international.

[2]  A. Moinzadeh,et al.  Face, content, and construct validity of dV-trainer, a novel virtual reality simulator for robotic surgery. , 2009, Urology.

[3]  I. Gill,et al.  Face, content and construct validity of a novel robotic surgery simulator. , 2011, The Journal of urology.

[4]  M. Sangalli,et al.  Impact of the learning curve on perioperative outcomes in patients who underwent robotic partial nephrectomy for parenchymal renal tumours. , 2010, European urology.

[5]  Melina C Vassiliou,et al.  A global assessment tool for evaluation of intraoperative laparoscopic skills. , 2005, American journal of surgery.

[6]  Mitchell C. Benson,et al.  From proficiency to expert, when does the learning curve for robotic-assisted prostatectomies plateau? The Columbia University experience , 2007, World Journal of Urology.

[7]  S Duke Herrell,et al.  Robotic-assisted laparoscopic prostatectomy: what is the learning curve? , 2005, Urology.

[8]  A. Tewari,et al.  The learning curve for reducing complications of robotic‐assisted laparoscopic radical prostatectomy by a single surgeon , 2011, BJU international.

[9]  Chandru P Sundaram,et al.  Validation of a novel virtual reality robotic simulator. , 2009, Journal of endourology.

[10]  T. Kesavadas,et al.  Face validation of a novel robotic surgical simulator. , 2010, Urology.

[11]  M. Lerner,et al.  Does training on a virtual reality robotic simulator improve performance on the da Vinci surgical system? , 2010, Journal of endourology.