Which pivot calibration?

Estimating the location of a tracked tool’s tip relative to its Dynamic Reference Frame (DRF) and localizing a specific point in a tracking system’s coordinate frame are fundamental tasks in image-guided procedures. The most common approach to estimating these values is by pivoting a tool around a fixed point. The transformations from the tracking system’s frame to the tool's DRF are the input. The output is the translation from the DRF to the tool’s tip and the translation from the tracker’s frame to the pivoting point. While the input and output are unique, there are multiple mathematical formulations for performing this estimation task. The question is, are these formulations equivalent in terms of precision and accuracy? In this work we empirically evaluate three common formulations, a geometry based sphere fitting formulation and two algebraic formulations. In addition we evaluate robust variants of these formulations using the RANSAC framework. Our evaluation shows that the algebraic formulations yield estimates that are more precise and accurate than the sphere fitting formulation. Using the Vicra optical tracking system from Northern Digital Inc., we observed that the algebraic approaches have a mean(std) precision of 0.25(0.11)mm localizing the pivoting point relative to the tracked DRF, and yield a fiducial registration error with a mean(std) 0.15(0.08)mm when registering a precisely constructed divot phantom to the localized points in the tracking system's frame. The sphere fitting formulation yielded less precise and accurate results with a mean(std) of 0.35(0.21)mm for precision and 0.25(0.14)mm for accuracy. The robust versions of these formulations yield similar results even when the data is contaminated with 30% outliers.

[1]  R. Laskin,et al.  Total knee replacement. , 1982, AORN journal.

[2]  S. Delp,et al.  Computer assisted knee replacement. , 1998, Clinical orthopaedics and related research.

[3]  David A. Simon,et al.  Range of motion after total hip arthroplasty: experimental verification of the analytical simulator , 1997, CVRMed.

[4]  Ziv Yaniv,et al.  Needle-Based Interventions With the Image-Guided Surgery Toolkit (IGSTK): From Phantoms to Clinical Trials , 2010, IEEE Transactions on Biomedical Engineering.

[5]  Z. Yaniv Random Sample Consensus (RANSAC) Algorithm, A Generic Implementation , 2010, The Insight Journal.

[6]  Jocelyne Troccaz,et al.  CVRMed-MRCAS'97 , 1997, Lecture Notes in Computer Science.

[7]  Robert C. Bolles,et al.  Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography , 1981, CACM.

[8]  Gábor Székely,et al.  Calibration, Registration, and Synchronization for High Precision Augmented Reality Haptics , 2009, IEEE Transactions on Visualization and Computer Graphics.

[9]  Emad M. Boctor,et al.  Tracked 3D ultrasound in radio-frequency liver ablation , 2003, SPIE Medical Imaging.

[10]  Michael A. Peshkin,et al.  Total Knee Replacement , 1973, The Lancet.

[11]  S Baron,et al.  Percutaneous inner-ear access via an image-guided industrial robot system , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  Philippe Cinquin,et al.  Computer-assisted knee surgical total replacement , 1997, CVRMed.

[13]  W. A. Bass,et al.  An ultrasonic approach to localization of fiducial markers for interactive, image-guided neurosurgery. II. Implementation and automation , 1998, IEEE Transactions on Biomedical Engineering.

[14]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.

[15]  Efrén Gorrostieta Hurtado,et al.  A Fully Sensorized Cooperative Robotic System for Surgical Interventions , 2012, Sensors.

[16]  Derek R. Magee,et al.  An augmented reality simulator for ultrasound guided needle placement training , 2007, Medical & Biological Engineering & Computing.

[17]  Ziv Yaniv Localizing spherical fiducials in C-arm based cone-beam CT. , 2009, Medical physics.

[18]  Wolfgang Birkfellner,et al.  Calibration of tracking systems in a surgical environment , 1998, IEEE Transactions on Medical Imaging.

[19]  Frank Sauer,et al.  A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method , 2005, MICCAI.

[20]  M. Peshkin,et al.  Registration and immobilization in robot-assisted surgery. , 1995, Journal of image guided surgery.