Irregular heartbeat detection using sequentially truncated multilinear singular value decomposition

This paper presents a novel approach for detecting irregular heartbeats using tensor approximation and Least Squares — Support Vector Machines (LS-SVM). Once the signal is filtered and normalized, a third order tensor was constructed for each record of the dataset. Next, a Sequentially Truncated Multilinear Singular Value Decomposition (ST-MLSVD) was applied and the mode-3 matrix was used as input features for an LS-SVM. Then, Active Prototype Vector (APV) selection strategy was performed for selecting 5% of the data for training. The LS-SVM hyper-parameters tuning was carried out using a combination of Coupled Simulated Annealing and the simplex method. Two databases were used for the performance evaluation. This evaluation resulted in sensitivities, positive predictive values and specificities all above 93%. These results are an improvement on previously reported results for tensor-based irregular heartbeat detection systems.

[1]  Johan A. K. Suykens,et al.  LS-SVMlab : a MATLAB / C toolbox for Least Squares Support Vector Machines , 2007 .

[2]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[3]  Raf Vandebril,et al.  A New Truncation Strategy for the Higher-Order Singular Value Decomposition , 2012, SIAM J. Sci. Comput..

[4]  Sabine Van Huffel,et al.  Detection of irregular heartbeats using tensors , 2015, 2015 Computing in Cardiology Conference (CinC).

[5]  Sabine Van Huffel,et al.  Irregular heartbeats detection using tensors and Support Vector Machines , 2016, 2016 Computing in Cardiology Conference (CinC).

[6]  G.B. Moody,et al.  The impact of the MIT-BIH Arrhythmia Database , 2001, IEEE Engineering in Medicine and Biology Magazine.

[7]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[8]  Johan A. K. Suykens,et al.  Coupled Simulated Annealing , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics).

[9]  Johan A. K. Suykens,et al.  Optimized fixed-size kernel models for large data sets , 2010, Comput. Stat. Data Anal..

[10]  Marek Correspondence,et al.  Guidelines Heart rate variability Standards of measurement , physiological interpretation , and clinical use Task Force of The European Society of Cardiology and The North American Society of Pacing and Electrophysiology ( Membership of the Task Force , 2005 .