Aqueous corrosion in static capsule tests representing multi-metal assemblies in the hydraulic circuit of Tore Supra

Abstract Tore supra (TS) in vessel components represent a unique combination of metals in the hydraulic circuit. Different materials, e.g. stainless steel, copper alloys, nickel, etc., were joined together by fusion welding, brazing and friction. Since the operation and baking temperature of all in vessel components has been defined to be set at 230 °C/40 bars a special water chemistry of the cooling water loop was suggested in order to prevent eventual water leaks due to corrosion at relative high temperatures and pressures in tubes, bellows, coils and coolant plant ancillary equipments. Following experiences with water chemistry in Pressurised Water Reactors, an all volatile chemical treatment (AVT) has been defined for the cooling water quality of TS. Since then, a simplified static (no fluid circulation) corrosion test program at relatively high temperature and pressure has been performed using capsule-type samples made of above mentioned multi-metal assemblies.