Total knee arthroplasty with retention of both cruciate ligaments. A nine to eleven-year follow-up study.

BACKGROUND Although many early designs of total knee arthroplasty allowed the retention of both cruciate ligaments, in most current designs of knee replacement systems, either both cruciate ligaments are removed or the posterior cruciate ligament alone is retained. This report is a review of a series of total knee arthroplasties in which both cruciate ligaments were retained. METHODS The results of 163 total knee arthroplasties (130 patients) in which both cruciate ligaments were retained were assessed prospectively. One hundred and seven knees (eighty-nine patients) were followed for an average of ten years. There were thirty-four men and ninety-six women, and the average age at the time of the index arthroplasty was sixty-seven years (range, forty-two to eighty-four years). The diagnosis was osteoarthritis in 122 (75 percent) of the knees and rheumatoid arthritis in forty-one (25 percent). Twenty-six knees had a valgus deformity, 109 had a varus deformity, and twenty-eight had a normal alignment of 5 to 10 degrees of valgus. The anterior cruciate ligament was relatively normal in ninety-six knees and was partly degenerated in sixty-seven knees. With use of the rating system of the Knee Society, all 163 knees were prospectively evaluated at yearly intervals; fifty-six of these knees (in forty-one patients) were followed in this manner until the patient died or was lost to follow-up. RESULTS One hundred and four (97 percent) of the 107 knees available for study at an average of ten years had an excellent or good result. At the time of the latest follow-up, pain was adequately relieved in ninety-seven knees (91 percent) and the average range of flexion was 107+/-12.6 degrees (range, 65 to 135 degrees). Ninety-five knees (89 percent) had normal anteroposterior stability (less than five millimeters of movement in this plane), and twelve knees (11 percent) had five to ten millimeters of movement as demonstrated by the drawer sign. Ninety-six knees (90 percent) had normal mediolateral stability, and eleven (10 percent) had 5 to 10 degrees of laxity. Ninety-four knees (88 percent) had valgus alignment of 5 to 10 degrees. The average knee score was 91+/-8.4 points (range, 54 to 100 points), and the average functional score was 82+/-21 (range, 10 to 100 points). The survival rate at ten years, with revision as the end point, was 95+/-2.0 percent. Seven (4 percent) of the 163 knees in this series were revised. There were no revisions for patellar problems or aseptic loosening of the tibial component. CONCLUSIONS The good anteroposterior stability in this series after an average follow-up period of ten years indicates that both the anterior and the posterior cruciate ligaments, even when partly degenerated, remain functional when they are preserved in a total knee arthroplasty.

[1]  L. Whiteside,et al.  Cementless total knee replacement , 1994 .

[2]  J Jensen,et al.  Survivorship analysis of cemented total condylar knee arthroplasty. A long-term follow-up report on 348 cases. , 1996, The Journal of arthroplasty.

[3]  A. Lindstrand,et al.  Multicenter study of unicompartmental knee revision. PCA, Marmor, and St Georg compared in 3,777 cases of arthrosis. , 1992, Acta orthopaedica Scandinavica.

[4]  L. Marmor Unicompartmental arthroplasty for osteonecrosis of the knee joint. , 1993, Clinical orthopaedics and related research.

[5]  J. Coresh,et al.  Adjusting survival curves for confounders: a review and a new method. , 1996, American journal of epidemiology.

[6]  J O Galante,et al.  Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. , 1994, Clinical orthopaedics and related research.

[7]  T. Mallory,et al.  Townley anatomic total knee arthroplasty using total tibial component with cruciate release. , 1982, Clinical orthopaedics and related research.

[8]  P. Walker,et al.  Fixation of tibial components of knee prostheses. , 1981, The Journal of bone and joint surgery. American volume.

[9]  Cloutier Jm Long-term results after nonconstrained total knee arthroplasty. , 1991 .

[10]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[11]  C. Ranawat,et al.  Long-term results of total knee arthroplasty in class 3 and 4 rheumatoid arthritis. , 1996, The Journal of arthroplasty.

[12]  F. C. Ewald The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. , 1989, Clinical orthopaedics and related research.

[13]  M. Ritter,et al.  Long-term survival analysis of the posterior cruciate condylar total knee arthroplasty , 1989 .

[14]  J L Lewis,et al.  The effect of knee-prosthesis geometry on cruciate ligament mechanics during flexion. , 1982, The Journal of bone and joint surgery. American volume.

[15]  G. Scuderi**,et al.  The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up. , 1995, The Journal of bone and joint surgery. American volume.

[16]  T. Andriacchi,et al.  The influence of total knee-replacement design on walking and stair-climbing. , 1982, The Journal of bone and joint surgery. American volume.

[17]  M. B. Coventry,et al.  Geometric total knee arthroplasty. A two-year follow-up study. , 1976, The Journal of bone and joint surgery. American volume.

[18]  C. Ranawat,et al.  Long-term results of the total condylar knee arthroplasty. A 15-year survivorship study. , 1993, Clinical orthopaedics and related research.

[19]  R. Wixson,et al.  Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. , 1994, Clinical orthopaedics and related research.

[20]  J. O'Connor,et al.  The mechanics of the knee and prosthesis design. , 1978, The Journal of bone and joint surgery. British volume.

[21]  F H Gunston,et al.  POLYCENTRIC KNEE ARTHROPLASTY: Prosthetic Simulation of Normal Knee Movement , 1971 .

[22]  F. H. Gunston,et al.  Complications of polycentric knee arthroplasty. , 1976, Clinical orthopaedics and related research.

[23]  C. G. Moran,et al.  Kinematic condylar total knee arthroplasty , 1996 .

[24]  Whiteside La,et al.  Cementless total knee replacement. Nine- to 11-year results and 10-year survivorship analysis. , 1994 .

[25]  R. Bourne,et al.  Posteromedial tibial polyethylene failure in total knee replacements. , 1994, Clinical orthopaedics and related research.

[26]  R. Bryan,et al.  Total knee arthroplasty with the kinematic condylar prosthesis. A ten-year follow-up study. , 1995, The Journal of bone and joint surgery. American volume.

[27]  J. Pritchett,et al.  Anterior cruciate-retaining total knee arthroplasty. , 1996, The Journal of arthroplasty.

[28]  J. Cloutier Results of total knee arthroplasty with a non-constrained prosthesis. , 1983, The Journal of bone and joint surgery. American volume.

[29]  G. Engh,et al.  Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. , 1992, The Journal of bone and joint surgery. British volume.

[30]  C. Sledge,et al.  Total knee arthroplasty experience at the Robert Breck Brigham Hospital. , 1979, Clinical Orthopaedics and Related Research.

[31]  C. Townley Total knee arthroplasty. A personal retrospective and prospective review. , 1988, Clinical Orthopaedics and Related Research.

[32]  P. Rozing,et al.  Survivorship analysis in total condylar knee arthroplasty. A statistical review. , 1992, The Journal of bone and joint surgery. American volume.

[33]  R. Bourne,et al.  The Miller-Galante knee prosthesis for the treatment of osteoarthrosis. A comparison of the results of partial fixation with cement and fixation without any cement. , 1993, The Journal of bone and joint surgery. American volume.