Characterization of different water/powder ratios of dental gypsum using fiber Bragg grating sensors.

The impact of five different water/powder (w/p) ratios in the characterization of high strength dental stone was evaluated, since the recommendations of the gypsum' manufacturers are not always correctly followed by the dental prosthesis technicians. Fiber Bragg grating (FBG) sensors were used to measure the setting expansion and temperature variation which occurred during the setting reaction for each w/p ratio, as well as the thermal expansion coefficient. Thick mixtures with low w/p ratios had more crystals impinging upon each other during crystal growth, resulting in more expansion and more heat released. This thermal behavior was only achieved to w/p ratios within the manufacturer-recommended mixing ratio range. The results also revealed the existence of boundary condition; this corresponding to the limit of the mixing ratio recommended by the gypsum' manufacturer. Data provided in this study are particularly important for dental technicians with a view to attaining the best results in accuracy of fit for their prosthetic works.

[1]  E. Lautenschlager,et al.  Freeze-drying and scanning electron microscopy of setting dental gypsum. , 1995, Dental materials : official publication of the Academy of Dental Materials.

[2]  Lídia Carvalho,et al.  Determination of setting expansion of dental materials using fibre optical sensing , 2006 .

[3]  J. Rees,et al.  The polymerization shrinkage of composite resins. , 1989, Dental materials : official publication of the Academy of Dental Materials.

[4]  Pekka K Vallittu,et al.  Evaluation of polymerization shrinkage and hydroscopic expansion of fiber-reinforced biocomposites using optical fiber Bragg grating sensors. , 2008, Dental materials : official publication of the Academy of Dental Materials.

[5]  N. Pleros,et al.  Two dimensional polymer-embedded quasi-distributed FBG pressure sensor for biomedical applications. , 2010, Optics express.

[6]  Young-Geun Han,et al.  Sensitive DNA biosensor based on a long-period grating formed on the side-polished fiber surface. , 2009, Optics express.

[7]  Michael A. Davis,et al.  Fiber grating sensors , 1997 .

[8]  E. Lautenschlager,et al.  Investigation on the Expansion of Dental Stone , 1969, Journal of dentistry research.

[9]  Chun-Gon Kim,et al.  Simultaneous measurement of strain and temperature using a reverse index fiber Bragg grating sensor , 2010 .

[10]  E. W. Skinner,et al.  Skinner's science of dental materials , 1973 .

[11]  S. Mondal,et al.  Fiber Bragg grating sensor for monitoring bone decalcification. , 2010, Orthopaedics & traumatology, surgery & research : OTSR.

[12]  W H Douglas,et al.  Strain gauge method for measuring polymerization contraction of composite restoratives. , 1991, Journal of dentistry.

[13]  G. C. Poddar,et al.  Embedded dual fiber Bragg grating sensor for simultaneous measurement of temperature and load (strain) with enhanced sensitivity , 2009 .

[14]  R. G. Craig Restorative dental materials , 1971 .

[15]  Laurence J Walsh,et al.  Performance assessment of novel side firing flexible optical fibers for dental applications , 2009, Lasers in surgery and medicine.

[16]  Ping Lu,et al.  Resolving cross sensitivity of fiber Bragg gratings with different polymeric coatings , 2008 .

[17]  D C Watts,et al.  Determination of polymerization shrinkage kinetics in visible-light-cured materials: methods development. , 1991, Dental materials : official publication of the Academy of Dental Materials.

[18]  M. S. Milczewski,et al.  Measurement of composite shrinkage using a fibre optic Bragg grating sensor , 2007, Journal of biomaterials science. Polymer edition.

[19]  D. B. Mahler,et al.  An Explanation for the Hygroscopic Setting Expansion of Dental Gypsum Products , 1960, Journal of dental research.

[20]  W. Cook,et al.  A simple method for the measurement of polymerization shrinkage in dental composites. , 1999, Dental materials : official publication of the Academy of Dental Materials.