Analytical model and spectral correction of vibration effects on Fourier transform spectrometer

Sensitivity to mechanical vibrations of Fourier Transform Spectrometers (FTS) is a well-known phenomenon. It is especially critical for FTS devoted to atmospheric studies (like the Planetary Fourier Spectrometer (PFS) onboard Mars Express 2003), as absorption bands for the gases of low concentration are comparable with the generated instrument spectral noise. The adopted techniques for the vibration sensitivity reduction suffer of limitations in practical implementation, leaving residual modulations of the interferogram and the so-called ghosts in the spectra. Moreover as it is often impossible to measure the vibrations during the FTS measurement, the position and magnitude of these ghosts cannot be evaluated. Up to now the adopted ghost reduction techniques are mostly based on the averaging of spectra, because the disturbance phase is randomly distributed. This paper presents an innovative data treatment technique which allows single spectrum correction from distortions of unknown nature. Such a technique would increase the spatial resolution of the mapping process and becomes crucial when the desired information is linked to a particular mapping area associated to an individual spectrum. The full study consists in the explicit analysis of the ghost formation and the post-processing algorithm based on the semiblind deconvolution method – an iterative numerical algorithm of the series of consecutive deconvolutions. The technique was tested on the data from the PFS and the algorithm proved to be consistent according to the selected efficiency criteria (coming from the available general information about the signal spectral shape).

[1]  Giuseppe Piccioni,et al.  The Planetary Fourier Spectrometer (PFS) for the orbiter of the spacecraft Mars 96 , 1996 .

[2]  L Palchetti,et al.  Spectral noise due to sampling errors in Fourier-transform spectroscopy. , 2001, Applied optics.

[3]  D L Cohen Performance degradation of a Michelson interferometer due to random sampling errors. , 1999, Applied optics.

[4]  E. E. Bell,et al.  Spectral errors resulting from random sampling-position errors in fourier transform spectroscopy. , 1972, Applied optics.

[5]  Lorenzo Comolli,et al.  Mechanical disturbances in Fourier spectrometers. , 2007, Applied optics.

[6]  Angioletta Coradini,et al.  Infrared spectrometer PFS for the Mars 94 orbiter , 1996 .

[7]  Angioletta Coradini,et al.  PFS: A fourier spectrometer for the study of Martian atmosphere , 1997 .

[8]  A S Zachor,et al.  Delay compensation: its effect in reducing sampling errors in Fourier spectroscopy. , 1979, Applied optics.

[9]  Alessandro Maturilli,et al.  PFS for Mars Express: A new approach to study Martian atmosphere , 2002 .

[10]  Giuseppe Piccioni,et al.  Calibration of the Planetary Fourier Spectrometer short wavelength channel , 2005 .

[11]  David Crisp,et al.  The planetary fourier spectrometer (PFS) onboard the European Venus Express mission , 2005 .

[12]  Lorenzo Comolli,et al.  Evaluation of the sensitivity to mechanical vibrations of an IR Fourier spectrometer , 2005 .

[13]  Toshihiko Yamawaki,et al.  Transfer Functions of Microvibrational Disturbances on a Satellite , 2003 .