How extensive of a 4D dataset is needed to estimate cumulative dose distribution plan evaluation metrics in conformal lung therapy?

The purpose of this study was to investigate the number of intermediate states required to adequately approximate the clinically relevant cumulative dose to deforming/moving thoracic anatomy in four-dimensional (4D) conformal radiotherapy that uses 6 MV photons to target tumors. Four patients were involved in this study. For the first three patients, computed tomography images acquired at exhale and inhale were available; they were registered using B-spline deformation model and the computed transformation was further used to simulate intermediate states between exhale and inhale. For the fourth patient, 4D-acquired, phase-sorted datasets were available and each dataset was registered with the exhale dataset. The exhale-inhale transformation was also used to simulate intermediate states in order to compare the cumulative doses computed using the actual and the simulated datasets. Doses to each state were calculated using the Dose Planning Method (DPM) Monte Carlo code and dose was accumulated for scoring on the exhale anatomy via the transformation matrices for each state and time weighting factors. Cumulative doses were estimated using increasing numbers of intermediate states and compared to simpler scenarios such as a "2-state" model which used only the exhale and inhale datasets or the dose received during the average phase of the breathing cycle. Dose distributions for each modeled state as well as the cumulative doses were assessed using dose volume histograms and several treatment evaluation metrics such as mean lung dose, normal tissue complication probability, and generalized uniform dose. Although significant "point dose" differences can exist between each breathing state, the differences decrease when cumulative doses are considered, and can become less significant yet in terms of evaluation metrics depending upon the clinical end point. This study suggests that for certain "clinical" end points of importance for lung cancer, satisfactory predictions of accumulated total dose to be received by the distorting anatomy can be achieved by calculating the dose to but a few (or even simply the average) phases of the breathing cycle.

[1]  Jan-Jakob Sonke,et al.  Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. , 2006, International journal of radiation oncology, biology, physics.

[2]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[3]  Randall K Ten Haken,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion. , 2003, Medical physics.

[4]  José Belderbos,et al.  Biology contributionComparing different NTCP models that predict the incidence of radiation pneumonitis , 2003 .

[5]  K. Lam,et al.  Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. , 1996, International journal of radiation oncology, biology, physics.

[6]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[7]  Michael Unser,et al.  Splines: a perfect fit for signal and image processing , 1999, IEEE Signal Process. Mag..

[8]  Indrin J Chetty,et al.  Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media. , 2003, Medical physics.

[9]  J. Sempau,et al.  DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations , 2000 .

[10]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[11]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[12]  R Mohan,et al.  Predicting respiratory motion for four-dimensional radiotherapy. , 2004, Medical physics.

[13]  M Engelsman,et al.  The effect of breathing and set-up errors on the cumulative dose to a lung tumor. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  F. Vicini,et al.  Potential survival advantage with early androgen deprivation for biochemical failure after external beam radiotherapy: the importance of accurately defining biochemical disease status. , 2003, International journal of radiation oncology, biology, physics.

[15]  Radhe Mohan,et al.  Tumor control probability predictions for genetic radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[16]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[17]  George Starkschall,et al.  Displacement-based binning of time-dependent computed tomography image data sets. , 2006, Medical physics.

[18]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[19]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[20]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[21]  Steve B. Jiang,et al.  Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations , 2006, Physics in medicine and biology.

[22]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[23]  M. V. van Herk,et al.  Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment. , 2006, International journal of radiation oncology, biology, physics.

[24]  Di Yan,et al.  Minimization of target margin by adapting treatment planning to target respiratory motion , 2003 .

[25]  L. Xing,et al.  Image interpolation in 4D CT using a BSpline deformable registration model. , 2006, International journal of radiation oncology, biology, physics.

[26]  Timothy D. Solberg,et al.  Phase versus amplitude sorting of 4D‐CT data , 2006, Journal of applied clinical medical physics.

[27]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[28]  H Shirato,et al.  Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[29]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[30]  Joos V Lebesque,et al.  Comparing different NTCP models that predict the incidence of radiation pneumonitis. Normal tissue complication probability. , 2003, International journal of radiation oncology, biology, physics.

[31]  Quynh-Thu Le,et al.  The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgery. , 2002, International journal of radiation oncology, biology, physics.

[32]  Indrin J Chetty,et al.  Dose reconstruction in deforming lung anatomy: dose grid size effects and clinical implications. , 2005, Medical physics.

[33]  C. Burman,et al.  Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method. , 1989, International journal of radiation oncology, biology, physics.

[34]  I. Chetty,et al.  Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning. , 2006, International journal of radiation oncology, biology, physics.