Multielectrode spiral cuff for ordered and reversed activation of nerve fibres.

In this paper we present the modelling, design, and experimental testing of a nerve cuff multielectrode system for selective activation of fibres in superficial peripheral nerve trunk regions which is capable of activating fibres in physiological order. The multielectrode system consists of 45 platinum electrodes embedded within a self-curling spiral silicone sheet organized in fifteen longitudinal groups consisting of three electrodes spaced equidistally around the circumference of the cuff. Electrodes in the centre band acted as stimulating cathodes while the two electrodes of the same group in the two outer bands were connected together and corresponded to the position of a particular cathode, serving as anodes to block the nascent action potentials by membrane hyperpolarization. The interpolar distance was 6 mm on both sides, resulting in a total cuff length of about 20 mm. The cuff was constructed with a diameter to fit the size of the dog sciatic nerve. Preliminary animal testing of the nerve cuff was performed on the sciatic nerve of a Bigley female dog. In the 45-electrode stimulation system, biphasic cathodic first pulses with quasitrapezoidal-shaped cathodic and square anodic parts were delivered through the particular group of tripolar electrodes to effect both selective stimulation of motor axons within the gastrocnemius muscle fascicle, and differential block by membrane hyperpolarization. The test was repeated using rectangular cathodic first biphasic current pulses delivered monopolarly on the central electrode of the same group while connected anodes were replaced by a common anode situated elsewhere in the surrounding tissue. In both experiments an isometric torque in the ankle joint elicited by the gastrocnemius muscle was measured and compared.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  J. Mortimer,et al.  Selective activation of small motor axons by quasitrapezoidal current pulses , 1991, IEEE Transactions on Biomedical Engineering.

[2]  P.H. Veltink,et al.  Influences of stimulation conditions on recruitment of myelinated nerve fibres: a model study , 1988, IEEE Transactions on Biomedical Engineering.

[3]  J. Holsheimer,et al.  A modeling study of nerve fascicle stimulation , 1989, IEEE Transactions on Biomedical Engineering.

[4]  H Thoma,et al.  First implantation of a 16-channel electric stimulation device in the human body. , 1983, Transactions - American Society for Artificial Internal Organs.

[5]  Mary N. Morrow,et al.  A Comparison of Finite Element and Integral Equation Formulations for the Calculation of Electrocardiographic Potentials , 1985, IEEE Transactions on Biomedical Engineering.

[6]  C. Sherrington,et al.  Numbers and Contraction-Values of Individual Motor-Units Examined in some Muscles of the Limb , 1930 .

[7]  S. W. Kuffler,et al.  Function of medullated small-nerve fibers in mammalian ventral roots; efferent muscle spindle innervation. , 1951, Journal of neurophysiology.

[8]  P.H. Veltink,et al.  Simulation of intrafascicular and extraneural nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[9]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[10]  W. Willis,et al.  Evidence for a common location of alpha and gamma motoneurons. , 1972, Brain research.

[11]  C. R. Taylor,et al.  Distribution of fiber types in locomotory muscles of dogs. , 1982, The American journal of anatomy.

[12]  G. J. Romanes,et al.  Current Problems of Lower Vertebrate Phylogeny. , 1969 .

[13]  D. Mcneal Analysis of a Model for Excitation of Myelinated Nerve , 1976, IEEE Transactions on Biomedical Engineering.

[14]  J. K. Barclay,et al.  Physiological characteristics of skeletal muscles of dogs and cats. , 1977, The American journal of physiology.

[15]  D. A. Ksienski,et al.  A nerve cuff technique for selective excitation of peripheral nerve trunk regions , 1990, IEEE Transactions on Biomedical Engineering.

[16]  F. Rattay Analysis of Models for External Stimulation of Axons , 1986, IEEE Transactions on Biomedical Engineering.

[17]  Barry Coburn,et al.  A Theoretical Study of Epidural Electrical Stimulation of the Spinal Cord Part I: Finite Element Analysis of Stimulus Fields , 1985, IEEE Transactions on Biomedical Engineering.

[18]  J. Mortimer,et al.  The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation , 1983, IEEE Transactions on Biomedical Engineering.

[19]  F Rattay,et al.  Ways to approximate current-distance relations for electrically stimulated fibers. , 1987, Journal of theoretical biology.