Near-infrared spectroscopy monitoring of the collateral network prior to, during, and after thoracoabdominal aortic repair: a pilot study.

OBJECTIVE The aim of this study was to evaluate the feasibility of non-invasive monitoring of the paraspinous collateral network (CN) oxygenation prior to, during, and after thoracoabdominal aortic repair in a clinical series. METHODS Near-infrared spectroscopy optodes were positioned bilaterally-over the thoracic and lumbar paraspinous vasculature-to transcutaneously monitor muscle oxygenation of the CN in 20 patients (age: 66 ± 10 years; men = 11) between September 2010 and April 2012; 15 had open thoracoabdominal aortic repair (Crawford II and III), three had thoracic endovascular aortic repair (TEVAR; Crawford I), and two had a hybrid repair (Crawford II). CN oxygenation was continuously recorded until 48 hours postoperatively. RESULTS Hospital mortality was 5% (n = 1), 15% suffered ischemic spinal cord injury (SCI). Mean thoracic CN oxygenation saturation was 75.5 ± 8% prior to anesthesia (=baseline) without significant variations throughout the procedure (during non-pulsatile cooling on cardiopulmonary bypass and with aortic cross-clamping; range = 70.6-79.5%). Lumbar CN oxygenation (LbS) dropped significantly after proximal aortic cross-clamping to a minimum after 11.7 ± 4 minutes (74 ± 13% of baseline), but fully recovered after restoration of pulsatile flow to 98.5% of baseline. During TEVAR, stent-graft deployment did not significantly affect LbS. Three patients developed relevant SCI (paraplegia n = 1/paraparesis n = 2). In these patients LbS reduction after aortic cross-clamping was significantly lower compared with patients who did not experience SCI (p = .041). CONCLUSIONS Non-invasive monitoring of CN oxygenation prior to, during, and after thoracoabdominal aortic repair is feasible. Lumbar CN oxygenation levels directly respond to compromise of aortic blood circulation.

[1]  M. Luehr,et al.  Paraplegia after extensive thoracic and thoracoabdominal aortic aneurysm repair: does critical spinal cord ischemia occur postoperatively? , 2008, The Journal of thoracic and cardiovascular surgery.

[2]  B. Lytle,et al.  Contemporary Analysis of Descending Thoracic and Thoracoabdominal Aneurysm Repair: A Comparison of Endovascular and Open Techniques , 2008, Circulation.

[3]  T. W. L. Scheeren,et al.  Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications , 2012, Journal of Clinical Monitoring and Computing.

[4]  M. Luehr,et al.  Perioperative management to improve neurologic outcome in thoracic or thoracoabdominal aortic stent-grafting. , 2006, The Annals of thoracic surgery.

[5]  C. Acher,et al.  Low incidence of paraplegia after thoracic endovascular aneurysm repair with proactive spinal cord protective protocols. , 2013, Journal of vascular surgery.

[6]  J. Fehrenbacher,et al.  Early and late results of descending thoracic and thoracoabdominal aortic aneurysm open repair with deep hypothermia and circulatory arrest. , 2010, The Journal of thoracic and cardiovascular surgery.

[7]  J. Zentner,et al.  Setup of neurophysiological monitoring with tcMEP/SSEP during thoracoabdominal aneurysm repair. , 2005, The Thoracic and cardiovascular surgeon.

[8]  C. Miller,et al.  Analysis of motor and somatosensory evoked potentials during thoracic and thoracoabdominal aortic aneurysm repair. , 2009, Journal of vascular surgery.

[9]  B. Allen,et al.  Distal Aortic Perfusion and Cerebrospinal Fluid Drainage for Thoracoabdominal and Descending Thoracic Aortic Repair: Ten Years of Organ Protection , 2003, Annals of surgery.

[10]  B. Reichart,et al.  Optimizing cerebral oxygenation during cardiac surgery: a review of experimental and clinical investigations with near infrared spectrophotometry. , 2000, The Thoracic and cardiovascular surgeon.

[11]  J. Murkin Perioperative Multimodality Neuromonitoring: An Overview , 2004, Seminars in cardiothoracic and vascular anesthesia.

[12]  C. Etz,et al.  The collateral network concept: a reassessment of the anatomy of spinal cord perfusion. , 2011, The Journal of thoracic and cardiovascular surgery.

[13]  A. Khoynezhad,et al.  Improved outcome after repair of descending and thoracoabdominal aortic aneurysms using modern adjuncts. , 2005, Interactive cardiovascular and thoracic surgery.

[14]  M. Luehr,et al.  Selective cerebral perfusion at 28 degrees C--is the spinal cord safe? , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  J. Tobias,et al.  Hemodynamic changes following the administration of propofol to facilitate endotracheal intubation during sevoflurane anesthesia. , 2013, International journal of clinical and experimental medicine.

[16]  I. Taşoğlu,et al.  Near‐Infrared Spectroscopy Monitoring of the Spinal Cord During Type B Aortic Dissection Surgery , 2013, Journal of cardiac surgery.

[17]  R. Cambria,et al.  Contemporary Management of Descending Thoracic and Thoracoabdominal Aortic Aneurysms: Endovascular Versus Open , 2008, Circulation.

[18]  C. Etz,et al.  Direct spinal cord perfusion pressure monitoring in extensive distal aortic aneurysm repair. , 2009, The Annals of thoracic surgery.

[19]  Isabelle Van Herzeele,et al.  Near-Infrared Spectroscopy for Monitoring Spinal Cord Ischemia During Hybrid Thoracoabdominal Aortic Aneurysm Repair , 2011, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[20]  C. Piantadosi,et al.  Near-infrared spectroscopy for monitoring muscle oxygenation. , 2000, Acta physiologica Scandinavica.

[21]  T. Higami,et al.  Treatment of delayed neurological deficits after surgical repair of thoracic aortic aneurysm. , 2012, Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia.