Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human Muscle

The noninvasive thermometry method is based on the temperature dependence of the proton resonance frequency (PRF). High‐quality temperature images can be obtained from phase information of standard gradient‐echo sequences with an accuracy of 0.2°C in phantoms. This work was focused on the in vivo capabilities of this method. An experimental setup was designed that allows a qualitative in vivo verification. The lower‐leg muscles of a volunteer were cooled and afterwards reheated with an external water bolus. The temperature of the bolus water varied between 17°C and 37°C. The in vivo temperature images can be used to extract the temperature in muscle tissue. The data in the fat tissue are difficult to interpret because of the predominance of susceptibility effects. The results confirm the method's potential for hyperthermia control.

[1]  Harold A. Scheraga,et al.  Structure of Water and Hydrophobic Bonding in Proteins. I. A Model for the Thermodynamic Properties of Liquid Water , 1962 .

[2]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[3]  D. Ives,et al.  Structure and properties of water , 1968 .

[4]  Dennis L. Parker,et al.  Applications of NMR Imaging in Hyperthermia: An Evaluation of the Potential for Localized Tissue Heating and Noninvasive Temperature Monitoring , 1984, IEEE Transactions on Biomedical Engineering.

[5]  L. Hall,et al.  Mapping of pH and temperature distribution using chemical-shift-resolved tomography , 1985 .

[6]  F A Jolesz,et al.  MR imaging of laser-tissue interactions. , 1988, Radiology.

[7]  D Le Bihan,et al.  Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. , 1989, Radiology.

[8]  C Thomsen,et al.  A method for MR quantification of flow velocities in blood and CSF using interleaved gradient-echo pulse sequences. , 1989, Magnetic resonance imaging.

[9]  J. Pekar,et al.  Echo-planar imaging of intravoxel incoherent motion. , 1990, Radiology.

[10]  A. S. Hall,et al.  Observation by MR imaging of in vivo temperature changes induced by radio frequency hyperthermia. , 1990, Journal of computer assisted tomography.

[11]  Evaluation of the susceptibility effect on the phase images of a simple gradient echo. , 1990, Radiology.

[12]  R. Weisskoff,et al.  MRI susceptometry: Image‐based measurement of absolute susceptibility of MR contrast agents and human blood , 1992, Magnetic resonance in medicine.

[13]  Y. Ishihara,et al.  A precise and fast temperature mapping method using water proton chemical shift , 1992 .

[14]  C A Cuenod,et al.  Temperature changes induced in human muscle by radio-frequency H-1 decoupling: measurement with an MR imaging diffusion technique. Work in progress. , 1992, Radiology.

[15]  C. Cuénod,et al.  Simultaneous temperature and regional blood volume measurements in human muscle using an MRI fast diffusion technique , 1993, Magnetic resonance in medicine.

[16]  W. Hull,et al.  A 1H‐NMR method for determining temperature in cell culture perfusion systems , 1993, Magnetic resonance in medicine.

[17]  Eric Achten,et al.  The Proton-Resonance-Frequency-Shift Method Compared with Molecular Diffusion for Quantitative Measurement of Two-Dimensional Time-Dependent Temperature Distribution in a Phantom , 1994 .