Maximizing contrast‐to‐noise ratio in ultra‐high resolution peripheral MR angiography using a blood pool agent and parallel imaging
暂无分享,去创建一个
Tim Leiner | Jeffrey H Maki | David R Haynor | D. Haynor | T. Leiner | G. Wilson | J. Maki | Maisie S Wang | Gregory J Wilson | Maisie Wang
[1] C. Catalano,et al. ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings , 2005, European Radiology.
[2] D. Look,et al. Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .
[3] S. F. Quinn,et al. Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhanced MR angiography--multicenter comparative phase III study. , 2005, Radiology.
[4] R. Lauffer,et al. Preclinical evaluation of the pharmacokinetics, biodistribution, and elimination of MS-325, a blood pool agent for magnetic resonance imaging. , 1997, Investigative radiology.
[5] J. Mintorovitch,et al. Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths , 2005, Investigative radiology.
[6] E R McVeigh,et al. The effect of high performance gradients on fast gradient echo imaging , 1994, Magnetic resonance in medicine.
[7] A. Wiethoff,et al. Initial imaging recommendations for Vasovist angiography , 2006, European radiology.
[8] S. Schoenberg,et al. Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coil , 2005, Magnetic resonance in medicine.
[9] Peter Boesiger,et al. Sensitivity encoding as a means of enhancing the SNR efficiency in steady‐state MRI , 2005, Magnetic Resonance in Medicine.
[10] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[11] E Kent Yucel,et al. MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325. , 2005, Radiology.
[12] R. Dolan,et al. MS-325: albumin-targeted contrast agent for MR angiography. , 1998, Radiology.
[13] A de Roos,et al. Blood pool contrast agents for cardiovascular MR imaging , 1999, Journal of magnetic resonance imaging : JMRI.
[14] M R Prince,et al. Optimizing three-dimensional gadolinium-enhanced magnetic resonance angiography. Original investigation. , 1998, Investigative radiology.
[15] C. Higgins,et al. Blood pool MR contrast agents for cardiovascular imaging , 2000, Journal of magnetic resonance imaging : JMRI.