Recent advances in sample preparation techniques to overcome difficulties encountered during quantitative analysis of small molecules from biofluids using LC-MS/MS.
暂无分享,去创建一个
Dietrich A. Volmer | D. Volmer | U. Kobold | Caroline Bylda | R. Thiele | Caroline Bylda | Roland Thiele | Uwe Kobold
[1] Ali Asghar Rajabi,et al. Solid-phase microextraction based on cetyltrimethylammonium bromide-coated magnetic nanoparticles for determination of antidepressants from biological fluids , 2012, Medicinal Chemistry Research.
[2] L. Soleo,et al. Application of the standard addition approach for the quantification of urinary benzene. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[3] C. Deng,et al. Facile synthesis of magnetic graphene and carbon nanotube composites as a novel matrix and adsorbent for enrichment and detection of small molecules by MALDI-TOF MS , 2012 .
[4] Thomas Hankemeier,et al. The influence of citrate, EDTA, and heparin anticoagulants to human plasma LC–MS lipidomic profiling , 2012, Metabolomics.
[5] N. Rastkari,et al. Magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes for the determination of phthalate monoesters in urine samples. , 2013, Journal of chromatography. A.
[6] Gongke Li,et al. Molecularly imprinted stir bar sorptive extraction coupled with high performance liquid chromatography for trace analysis of sulfa drugs in complex samples. , 2011, Talanta.
[7] K. Schug,et al. Restricted access media as a streamlined approach toward on-line sample preparation: recent advancements and applications. , 2013, Journal of separation science.
[8] T. Khayamian,et al. Aptamer based extraction followed by electrospray ionization-ion mobility spectrometry for analysis of tetracycline in biological fluids. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[9] A. Calafat,et al. Automated on-line column-switching HPLC-MS/MS method for the quantification of triclocarban and its oxidative metabolites in human urine and serum. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[10] H. Shokrollahi,et al. Nano-magnetic particles used in biomedicine: core and coating materials. , 2013, Materials science & engineering. C, Materials for biological applications.
[11] M. Kozak,et al. Sensitive measurement of serum 1α,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction. , 2011, Rapid communications in mass spectrometry : RCM.
[12] S. Yao,et al. Novel magnetic bovine serum albumin imprinted polymers with a matrix of carbon nanotubes, and their application to protein separation , 2011, Analytical and bioanalytical chemistry.
[13] M. Hennion,et al. Comparison of immunoextraction sorbents prepared from monoclonal and polyclonal anti-isoproturon antibodies and optimization of the appropriate monoclonal antibody-based sorbent for environmental and biological applications , 2001 .
[14] Jean-Nicholas Mess,et al. Elimination of LC-MS/MS matrix effect due to phospholipids using specific solid-phase extraction elution conditions. , 2010, Bioanalysis.
[15] Steve Silvester,et al. Profiling phospholipid elution in reversed-phase LC-MS/MS bioanalytical methods in order to avoid matrix effects. , 2012, Bioanalysis.
[16] Kaige Zhang,et al. Novel applications of molecularly-imprinted polymers in sample preparation , 2013 .
[17] H. Janssen,et al. An automated method for the analysis of phenolic acids in plasma based on ion-pairing micro-extraction coupled on-line to gas chromatography/mass spectrometry with in-liner derivatisation. , 2012, Journal of chromatography. A.
[18] N. Asakawa,et al. Sensitive determination of aspirin and its metabolites in plasma by LC-UV using on-line solid-phase extraction with methylcellulose-immobilized anion-exchange restricted access media. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[19] M. Vogeser,et al. Preparation of plasma samples for chromatographic analyses using functionalized ferromagnetic micro-particles manipulated in a high pressure liquid system. , 2009, Clinical biochemistry.
[20] C. Holliman,et al. Utilization of hydrophilic-interaction LC to minimize matrix effects caused by phospholipids. , 2012, Bioanalysis.
[21] Hongliang Jiang,et al. Supported liquid extraction versus liquid-liquid extraction for sample preparation in LC-MS/MS-based bioanalysis. , 2013, Bioanalysis.
[22] James L. Little,et al. Liquid chromatography-mass spectrometry/mass spectrometry method development for drug metabolism studies: Examining lipid matrix ionization effects in plasma. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[23] N. Day,et al. Development and validation of a liquid chromatographic-tandem mass spectrometric method for determination of piperaquine in plasma stable isotope labeled internal standard does not always compensate for matrix effects. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[24] P. Ginel,et al. Effects of haemolysis, lipaemia and bilirubinaemia on an enzyme-linked immunosorbent assay for cortisol and free thyroxine in serum samples from dogs. , 1998, Veterinary journal.
[25] B. Keevil,et al. A rapid direct assay for the routine measurement of oestradiol and oestrone by liquid chromatography tandem mass spectrometry , 2014, Annals of clinical biochemistry.
[26] Guoquan Liu,et al. Determination of methotrexate in human serum by high-performance liquid chromatography combined with pseudo template molecularly imprinted polymer. , 2009, Journal of chromatography. A.
[27] L. M. Gonçalves,et al. Another glimpse over the salting-out assisted liquid-liquid extraction in acetonitrile/water mixtures. , 2013, Journal of chromatography. A.
[28] Shaolian Zhou,et al. Critical Review of Development, Validation, and Transfer for High Throughput Bioanalytical LC-MS/MS Methods , 2005 .
[29] A. Furey,et al. The Application and Validation of HybridSPE-Precipitation Cartridge Technology for the Rapid Clean-up of Serum Matrices (from Phospholipids) for the Clinical Analysis of Serotonin, Dopamine and Melatonin , 2012, Chromatographia.
[30] T. K. Jensen,et al. Temporal variability in urinary excretion of bisphenol A and seven other phenols in spot, morning, and 24-h urine samples. , 2013, Environmental research.
[31] M D Luque de Castro,et al. Comparison of sample preparation approaches for phospholipids profiling in human serum by liquid chromatography-tandem mass spectrometry. , 2012, Journal of Chromatography A.
[32] J. Alvarez,et al. An automated method for measurement of methoxetamine in human plasma by use of turbulent flow on-line extraction coupled with liquid chromatography and mass spectrometric detection , 2012, Analytical and Bioanalytical Chemistry.
[33] Simon Taylor,et al. Modification of the ultrafiltration technique to overcome solubility and non-specific binding challenges associated with the measurement of plasma protein binding of corticosteroids. , 2006, Journal of pharmaceutical and biomedical analysis.
[34] S. Morita,et al. Simultaneous determination of dibucaine and naphazoline in human serum by monolithic silica spin column extraction and liquid chromatography-mass spectrometry. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[35] L. Andersson,et al. Molecularly imprinted polymer in microextraction by packed sorbent for the simultaneous determination of local anesthetics: lidocaine, ropivacaine, mepivacaine and bupivacaine in plasma and urine samples. , 2013, Biomedical chromatography : BMC.
[36] D. Fast,et al. Systematic evaluation of supported liquid extraction in reducing matrix effect and improving extraction efficiency in LC-MS/MS based bioanalysis for 10 model pharmaceutical compounds. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[37] R. Romero-González,et al. Compensation for matrix effects in gas chromatography-tandem mass spectrometry using a single point standard addition. , 2009, Journal of chromatography. A.
[38] O. Beck,et al. Determination of remifentanil in human plasma by liquid chromatography-tandem mass spectrometry utilizing micro extraction in packed syringe (MEPS) as sample preparation. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[39] Anne-Françoise Aubry,et al. LC-MS/MS bioanalytical challenge: ultra-high sensitivity assays. , 2011, Bioanalysis.
[40] Sergey A. Piletsky,et al. Custom synthesis of molecular imprinted polymers for biotechnological application. Preparation of a polymer selective for tylosin , 2004 .
[41] M. Abdel-Rehim. Recent advances in microextraction by packed sorbent for bioanalysis. , 2010, Journal of chromatography. A.
[42] Thomas P. Mechtler,et al. Simplified newborn screening protocol for lysosomal storage disorders. , 2011, Clinical chemistry.
[43] Yuan-Qing Xia,et al. Systematic LC-MS/MS bioanalytical method development that incorporates plasma phospholipids risk avoidance, usage of incurred sample and well thought-out chromatography. , 2010, Biomedical chromatography : BMC.
[44] Baldev Singh,et al. Quantification of Tricyclic and Nontricyclic Antidepressants in Spiked Plasma and Urine Samples Using Microextraction in Packed Syringe and Analysis by LC and GC-MS , 2011 .
[45] Robert A. Anderson,et al. Analysis of ketamine and norketamine in hair samples using molecularly imprinted solid-phase extraction (MISPE) and liquid chromatography–tandem mass spectrometry (LC-MS/MS) , 2010, Analytical and bioanalytical chemistry.
[46] A. Kuksis,et al. Molecular species of glycerophospholipids and sphingomyelins of human plasma: Comparison to red blood cells , 1989, Lipids.
[47] Sergey A Piletsky,et al. Application of a molecularly imprinted polymer for the extraction of kukoamine a from potato peels. , 2012, Journal of agricultural and food chemistry.
[48] A. Akane,et al. Subzero-temperature liquid-liquid extraction of benzodiazepines for high-performance liquid chromatography. , 1999, Analytical chemistry.
[49] N. Nakov,et al. Development and validation of automated SPE-LC-MS/MS method for determination of indapamide in human whole blood and its application to real study samples. , 2013, Biomedical chromatography : BMC.
[50] D. Uges,et al. Reconsideration of sample pH adjustment in bioanalytical liquid-liquid extraction of ionisable compounds. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[51] Zhengqi Ye,et al. Minimizing matrix effects while preserving throughput in LC-MS/MS bioanalysis. , 2011, Bioanalysis.
[52] A. Salvador,et al. Solid-phase extraction liquid chromatography–tandem mass spectrometry analytical method for the determination of 2-hydroxy-4-methoxybenzophenone and its metabolites in both human urine and semen , 2010, Analytical and bioanalytical chemistry.
[53] Wen-Ting Lv. Investigation of the effects of 24 bio-matrices on the LC-MS/MS analysis of morinidazole. , 2010, Talanta.
[54] Naidong Weng,et al. Recent advances in application of hydrophilic interaction chromatography for quantitative bioanalysis. , 2010, Journal of separation science.
[55] K. Haupt,et al. Toward the use of a molecularly imprinted polymer in doping analysis: selective preconcentration and analysis of testosterone and epitestosterone in human urine. , 2010, Analytical chemistry.
[56] H. Zou,et al. Enrichment of peptides from plasma for peptidome analysis using multiwalled carbon nanotubes. , 2007, Journal of separation science.
[57] H. Oikawa,et al. Sequential extraction of amphetamines, opiates, and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid from a limited volume of urine using a monolithic silica spin column coupled with gas chromatography–mass spectrometry , 2013, Forensic Toxicology.
[58] P. Fürst,et al. Quick screening of priority β-agonists in urine using automated TurboFlow™-LC/Exactive mass spectrometry , 2011, Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment.
[59] A. Christophersen,et al. Determination of digoxin and digitoxin in whole blood. , 2009, Journal of analytical toxicology.
[60] F. Gasparrini,et al. New chiral and restricted-access materials containing glycopeptides as selectors for the high-performance liquid chromatographic determination of chiral drugs in biological matrices. , 2008, Journal of chromatography. A.
[61] C. Domeño,et al. Determination of bile acids in human serum by on-line restricted access material-ultra high-performance liquid chromatography-mass spectrometry. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[62] Steven T. Wu,et al. Plasma phospholipids implicated in the matrix effect observed in liquid chromatography/tandem mass spectrometry bioanalysis: evaluation of the use of colloidal silica in combination with divalent or trivalent cations for the selective removal of phospholipids from plasma. , 2008, Rapid communications in mass spectrometry : RCM.
[63] P. Kole,et al. Recent advances in sample preparation techniques for effective bioanalytical methods. , 2011, Biomedical chromatography : BMC.
[64] M Valcárcel,et al. Determination of non-steroidal anti-inflammatory drugs in urine by combining an immobilized carboxylated carbon nanotubes minicolumn for solid-phase extraction with capillary electrophoresis-mass spectrometry. , 2007, Journal of chromatography. A.
[65] Yiyu Cheng,et al. Immobilized magnetic beads based multi-target affinity selection coupled with high performance liquid chromatography-mass spectrometry for screening anti-diabetic compounds from a Chinese medicine "Tang-Zhi-Qing". , 2013, Journal of pharmaceutical and biomedical analysis.
[66] E. Gallardo,et al. Determination of seven selected antipsychotic drugs in human plasma using microextraction in packed sorbent and gas chromatography–tandem mass spectrometry , 2013, Analytical and Bioanalytical Chemistry.
[67] S. Magiera. Fast, simultaneous quantification of three novel cardiac drugs in human urine by MEPS-UHPLC-MS/MS for therapeutic drug monitoring. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[68] D. Neville,et al. Efficacy of plasma phospholipid removal during sample preparation and subsequent retention under typical UHPLC conditions. , 2012, Bioanalysis.
[69] M. Trojano,et al. Age-related changes of serum N-acetyl-aspartate in healthy controls. , 2011, Age and ageing.
[70] C. R. Bradley,et al. Screening and Initial Binding Assessment of Fumonisin B1 Aptamers , 2010, International journal of molecular sciences.
[71] L. Reubsaet,et al. Immuno-capture as ultimate sample cleanup in LC-MS/MS determination of the early stage biomarker ProGRP. , 2009, Journal of separation science.
[72] G. Hamscher,et al. Evaluation and subsequent minimization of matrix effects caused by phospholipids in LC-MS analysis of biological samples. , 2013, Bioanalysis.
[73] D. Meany,et al. An automated turbulent flow liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) method for quantitation of serum creatinine. , 2010, Clinica chimica acta; international journal of clinical chemistry.
[74] L. Couchman,et al. An automated method for the measurement of a range of tyrosine kinase inhibitors in human plasma or serum using turbulent flow liquid chromatography–tandem mass spectrometry , 2012, Analytical and Bioanalytical Chemistry.
[75] N. Asakawa,et al. Weak cation-exchange restricted-access material for on-line purification of basic drugs in plasma. , 2008, Journal of chromatography. A.
[76] Miqin Zhang,et al. Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging. , 2010, Advanced drug delivery reviews.
[77] K. G. Prasad,et al. Diatomaceous earth supported liquid extraction and LC-MS/MS determination of elvitegravir and ritonavir in rat plasma: application to a pharmacokinetic study , 2013 .
[78] Archana Jain,et al. Determination of amoxapine and nortriptyline in blood plasma and serum by salt-assisted liquid-liquid microextraction and high-performance liquid chromatography. , 2010, Journal of Separation Science.
[79] Wayne M Mullett,et al. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis. , 2007, Journal of biochemical and biophysical methods.
[80] Nicola C Hughes,et al. Assessing the matrix effects of hemolyzed samples in bioanalysis. , 2009, Bioanalysis.
[81] Md. Akhlaquer Rahman,et al. HybridSPE: A novel technique to reduce phospholipid-based matrix effect in LC–ESI-MS Bioanalysis , 2012, Journal of pharmacy & bioallied sciences.
[82] Li Li,et al. Development and validation of a LC-MS/MS method based on a new 96-well Hybrid-SPE™-precipitation technique for quantification of CYP450 substrates/metabolites in rat plasma , 2011, Analytical and bioanalytical chemistry.
[83] O. Beck,et al. Determination of four immunosuppressive drugs in whole blood using MEPS and LC-MS/MS allowing automated sample work-up and analysis. , 2012, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[84] Sara Tombelli,et al. New trends in affinity sensing: aptamers for ligand binding , 2003 .
[85] M. Urpi-Sardà,et al. Comparative analysis of sample preparation methods to handle the complexity of the blood fluid metabolome: when less is more. , 2013, Analytical chemistry.
[86] H. Frederiksen,et al. Serum concentrations of DHEA, DHEAS, 17α-hydroxyprogesterone, Δ4-androstenedione and testosterone in children determined by TurboFlow-LC-MS/MS. , 2013, Clinica chimica acta; international journal of clinical chemistry.
[87] M. Abdel-Rehim,et al. Screening and determination of drugs in human saliva utilizing microextraction by packed sorbent and liquid chromatography-tandem mass spectrometry. , 2013, Biomedical chromatography : BMC.
[88] Robert L. White,et al. Reducing glycerophosphocholine lipid matrix interference effects in biological fluid assays by using high-turbulence liquid chromatography. , 2008, Rapid communications in mass spectrometry : RCM.
[89] Xiangyu Jiang,et al. Automatic Supported Liquid Extraction (SLE) Coupled with HILIC-MS/MS: An Application to Method Development and Validation of Erlotinib in Human Plasma , 2010, Pharmaceutics.
[90] V. Pichon,et al. Synthesis and characterization of molecularly imprinted polymers for the selective extraction of cocaine and its metabolite benzoylecgonine from hair extract before LC-MS analysis. , 2012, Talanta.
[91] Hui-Yi Lin,et al. Determination of Diuretics in Urine Using Immobilized Multi‐Walled Carbon Nanotubes in Hollow Fiber Liquid‐Phase Microextraction Combined with Liquid Chromatography‐Tandem Mass Spectrometry , 2013 .
[92] Yuan-qing Xia,et al. Phospholipids in liquid chromatography/mass spectrometry bioanalysis: comparison of three tandem mass spectrometric techniques for monitoring plasma phospholipids, the effect of mobile phase composition on phospholipids elution and the association of phospholipids with matrix effects. , 2009, Rapid communications in mass spectrometry : RCM.
[93] Oscar Núñez,et al. State-of-the-art in fast liquid chromatography-mass spectrometry for bio-analytical applications. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[94] D. S. Hage,et al. System suitability in bioanalytical LC/MS/MS. , 2007, Journal of pharmaceutical and biomedical analysis.
[95] M. Eberlin,et al. Quantitation of drugs via molecularly imprinted polymer solid phase extraction and electrospray ionization mass spectrometry: benzodiazepines in human plasma. , 2011, The Analyst.
[96] V. Pichon,et al. Novel extraction supports based on immobilised aptamers: evaluation for the selective extraction of cocaine. , 2011, Talanta.
[97] Yin-liang Wu,et al. Multi-walled carbon nanotubes-dispersive solid-phase extraction combined with liquid chromatography-tandem mass spectrometry for the analysis of 18 sulfonamides in pork. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[98] A. Chaves,et al. Immunoaffinity in-tube solid phase microextraction coupled with liquid chromatography with fluorescence detection for determination of interferon α in plasma samples. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[99] Man Bock Gu,et al. Aptamers-on-nanofiber as a novel hybrid capturing moiety , 2011 .
[100] D. Volmer,et al. Development of an electrospray LC-MS/MS method for quantification of Δ(9) -tetrahydrocannabinol and its main metabolite in oral fluid. , 2012, Drug testing and analysis.
[101] M. Kozak,et al. Development of a liquid chromatography–tandem mass spectrometry method for plasma-free metanephrines with ion-pairing turbulent flow online extraction , 2012, Analytical and Bioanalytical Chemistry.
[102] S. Piletsky,et al. Analytical methods for determination of mycotoxins: a review. , 2009, Analytica chimica acta.
[103] Gongke Li,et al. Simultaneous determination of trace sterols in complicated biological samples by gas chromatography-mass spectrometry coupled with extraction using β-sitosterol magnetic molecularly imprinted polymer beads. , 2011, Journal of chromatography. A.
[104] Huaiqin Wu,et al. Simultaneous determination of a hydrophobic drug candidate and its metabolite in human plasma with salting-out assisted liquid/liquid extraction using a mass spectrometry friendly salt. , 2008, Journal of pharmaceutical and biomedical analysis.
[105] T. Schmidt,et al. Fully automated standard addition method for the quantification of 29 polar pesticide metabolites in different water bodies using LC-MS/MS , 2013, Analytical and Bioanalytical Chemistry.
[106] Sherry Wang,et al. Does a stable isotopically labeled internal standard always correct analyte response? A matrix effect study on a LC/MS/MS method for the determination of carvedilol enantiomers in human plasma. , 2007, Journal of pharmaceutical and biomedical analysis.
[107] Xingang Liu,et al. Simultaneous determination of cyflumetofen and its main metabolite residues in samples of plant and animal origin using multi-walled carbon nanotubes in dispersive solid-phase extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry. , 2013, Journal of chromatography. A.
[108] D. Volmer,et al. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes. , 2013, Rapid communications in mass spectrometry : RCM.
[109] P. Sandra,et al. Solid-phase extraction based on hydrophilic interaction liquid chromatography with acetone as eluent for eliminating matrix effects in the analysis of biological fluids by LC-MS , 2013, Analytical and Bioanalytical Chemistry.
[110] Takeshi Saito,et al. Monolith as a new sample preparation material: recent devices and applications. , 2011, Journal of separation science.
[111] D. Volmer,et al. Simultaneous quantification of acetaminophen and structurally related compounds in human serum and plasma. , 2013, Drug testing and analysis.
[112] L. Couchman. Turbulent flow chromatography in bioanalysis: a review. , 2012, Biomedical chromatography : BMC.
[113] Fabio Augusto,et al. New materials and trends in sorbents for solid-phase extraction , 2013 .
[114] D. Fast,et al. Determination of carboplatin in human plasma using HybridSPE-precipitation along with liquid chromatography-tandem mass spectrometry. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[115] H. Oikawa,et al. Mix-mode TiO-C_18 Monolith Spin Column Extraction and GC-MS for the Simultaneous Assay of Organophosphorus Compounds and Glufosinate, and Glyphosate in Human Serum and Urine , 2011, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[116] J. Veuthey,et al. Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[117] Takeshi Saito,et al. Monolithic silica spin column extraction and simultaneous derivatization of amphetamines and 3,4-methylenedioxyamphetamines in human urine for gas chromatographic-mass spectrometric detection. , 2010, Analytica chimica acta.
[118] Zhongze Gu,et al. The investigation of electrospun polymer nanofibers as a solid-phase extraction sorbent for the determination of trazodone in human plasma. , 2007, Analytica chimica acta.
[119] E. Kinoshita,et al. A Phos-tag-based magnetic-bead method for rapid and selective separation of phosphorylated biomolecules. , 2013, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[120] C. Huber,et al. On-line solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate , 2012, Analytical and Bioanalytical Chemistry.
[121] H. Karnes,et al. Investigation of endogenous blood plasma phospholipids, cholesterol and glycerides that contribute to matrix effects in bioanalysis by liquid chromatography/mass spectrometry. , 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[122] Erin Chambers,et al. Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[123] Michael Vogeser,et al. Deproteination of serum samples for LC-MS/MS analyses by applying magnetic micro-particles. , 2013, Clinical biochemistry.
[124] S. Inokuchi,et al. Monolithic spin column extraction and GC-MS for the simultaneous assay of diquat, paraquat, and fenitrothion in human serum and urine , 2011, Analytical and bioanalytical chemistry.
[125] Vincenzo Pucci,et al. A novel strategy for reducing phospholipids-based matrix effect in LC-ESI-MS bioanalysis by means of HybridSPE. , 2009, Journal of pharmaceutical and biomedical analysis.
[126] G. Rodchenkov,et al. Magnetic separation as a new method for the extraction of small molecules from biological fluids of humans , 2011 .
[127] Mohammed Jemal,et al. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard. , 2003, Rapid communications in mass spectrometry : RCM.
[128] D. Yuan,et al. Recent Developments of Extraction and Micro-extraction Technologies with Porous Monoliths , 2012 .
[129] H. Oikawa,et al. Rapid Determination of Polar and Non-Polar Pesticides in Human Serum, Using Mixed-Mode C-C18 Monolithic Spin Column Extraction and LC–MS/MS , 2013, Chromatographia.
[130] H. Hou,et al. Development of a method for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol in urine of nonsmokers and smokers using liquid chromatography/tandem mass spectrometry. , 2012, Journal of pharmaceutical and biomedical analysis.
[131] E. Crawford,et al. Bioanalysis without sample cleanup or chromatography: the evaluation and initial implementation of direct analysis in real time ionization mass spectrometry for the quantification of drugs in biological matrixes. , 2009, Analytical chemistry.
[132] H. Ouyang,et al. Microdosing Assessment to Evaluate Pharmacokinetics and Drug Metabolism in Rats Using Liquid Chromatography-Tandem Mass Spectrometry , 2008, Pharmaceutical Research.
[133] Hong-Ju Yang,et al. Simultaneous determination of 10 β2-agonists in swine urine using liquid chromatography-tandem mass spectrometry and multi-walled carbon nanotubes as a reversed dispersive solid phase extraction sorbent. , 2012, Journal of chromatography. A.
[134] M. Vogeser,et al. Sample Preparation for Measurement of Plasma Mycophenolic Acid Concentrations Using Chromatographically Functionalized Magnetic Micro-Particles , 2012, European journal of mass spectrometry.
[135] Daniel E Mulvana,et al. Critical topics in ensuring data quality in bioanalytical LC-MS method development. , 2010, Bioanalysis.
[136] N. Davies,et al. Hydrogen/deuterium exchange on aromatic rings during atmospheric pressure chemical ionization mass spectrometry. , 2010, Rapid communications in mass spectrometry : RCM.
[137] Lei Chen,et al. Restricted access magnetic materials prepared by dual surface modification for selective extraction of therapeutic drugs from biological fluids , 2012 .
[138] Jian Shi,et al. Development and validation of a liquid chromatography-tandem mass spectrometry method for topotecan determination in beagle dog plasma and its application in a bioequivalence study. , 2013, Biomedical chromatography : BMC.
[139] B. Ludes,et al. High-performance liquid chromatography-ionspray mass spectrometry for the specific determination of digoxin and some related cardiac glycosides in human plasma. , 1997, Journal of chromatography. B, Biomedical sciences and applications.
[140] Li Xu,et al. Restricted-access nanoparticles for magnetic solid-phase extraction of steroid hormones from environmental and biological samples. , 2012, Journal of chromatography. A.
[141] B. Matuszewski,et al. Matrix effect in quantitative LC/MS/MS analyses of biological fluids: a method for determination of finasteride in human plasma at picogram per milliliter concentrations. , 1998, Analytical chemistry.
[142] T. Olah,et al. The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds. , 1999, Rapid communications in mass spectrometry : RCM.
[143] E. Lai,et al. Molecularly imprinted polymer stir bar sorption extraction and electrospray ionization tandem mass spectrometry for determination of 2-aminothiazoline-4-carboxylic acid as a marker for cyanide exposure in forensic urine analysis , 2010 .
[144] Jim X. Shen,et al. Implementation of high-temperature superficially porous technologies for rapid LC-MS/MS diastereomer bioanalysis. , 2011, Bioanalysis.
[145] A. Otto,et al. Magnetic particles as powerful purification tool for high sensitive mass spectrometric screening procedures , 2009, Proteomics.
[146] Cynthia Côté,et al. Matrix effect elimination during LC-MS/MS bioanalytical method development. , 2009, Bioanalysis.
[147] Leimin Fan,et al. Recent advances in high-throughput quantitative bioanalysis by LC-MS/MS. , 2007, Journal of pharmaceutical and biomedical analysis.
[148] C. Huber,et al. Rapid narrow band elution for on-line SPE using a novel solvent plug injection technique , 2012, Analytical and Bioanalytical Chemistry.
[149] A. Martín‐Esteban. Molecularly-imprinted polymers as a versatile, highly selective tool in sample preparation , 2013 .
[150] Huaiqin Wu,et al. Salting-out assisted liquid/liquid extraction with acetonitrile: a new high throughput sample preparation technique for good laboratory practice bioanalysis using liquid chromatography-mass spectrometry. , 2009, Biomedical chromatography : BMC.
[151] Takeshi Saito,et al. Extraction of amphetamines and methylenedioxyamphetamines from urine using a monolithic silica disk-packed spin column and high-performance liquid chromatography-diode array detection. , 2008, Journal of chromatography. A.
[152] B. Matuszewski,et al. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.
[153] L. Couchman,et al. An automated method for the simultaneous measurement of azole antifungal drugs in human plasma or serum using turbulent flow liquid chromatography-tandem mass spectrometry , 2012, Analytical and Bioanalytical Chemistry.
[154] V. Pichon,et al. Molecularly imprinted polymer for analysis of zidovudine and stavudine in human serum by liquid chromatography-mass spectrometry. , 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.
[155] O. Nielsen,et al. Bisphenol A and other phenols in urine from Danish children and adolescents analyzed by isotope diluted TurboFlow-LC-MS/MS. , 2013, International journal of hygiene and environmental health.
[156] B. Li,et al. Magnetic molecularly imprinted polymer extraction of chloramphenicol from honey. , 2013, Food chemistry.
[157] E. Peyrin,et al. Determination of cocaine in human plasma by selective solid-phase extraction using an aptamer-based sorbent. , 2009, Analytical chemistry.
[158] Zhenmin Liang,et al. Perspectives on addressing ionization matrix effects in LC-MS bioanalysis. , 2012, Bioanalysis.